im-tek.com

Aoip CALYS 150 Field Instruments

Aoip

Product Code: CALYS 150
Brand: Aoip



GET OFFER: info@imtek.com.tr

Description for Aoip CALYS 150 Field Instruments

CALYS 150 field documenting multifunction calibrator is the top instrument of the range. It is the perfect tool for advanced process maintenance and use on test bench in all industries. Suitable for all field and lab measurements, it can simultaneously measure and generate over two isolated channels various signals of temperature, resistance, process, pressure and frequency in one single instrument. CALYS 150 does not only work as a simulator (IN / OUT) but also as a dual channel thermometer (IN / IN) to perform comparison calibration. It calibrates HART transmitters (HART communicator integrated into ACL500 modem) and thermistors. Providing extended functionalities (temperature simulation, scaling, steps, synthesizer, statistical functions…) and audit trails, CALYS 150 complies with both 21 CFR Part 11 and NADCAP Heat Treatment standards and makes advanced data exploitation and full data traceability easier. High performances for CALYS 150, for advanced use:Temperature Up to 0.005 % RDGResistance Up to 0.006 % RDG and 50 K? rangeCurrent: Up to 0.007 % RDG and 100 mA range + Loop Supply 24 VVoltage: Up to 0.005 % RDG and 50 V rangeFrequency: Up to 0.01 % RDG and 100 KHz rangePressure: With an external pressure module (comparison calibration with a pressure pump)Using this user-friendly instrument, calibration tasks can be quickly carried out over the whole process chain. Take the 900 g documenting process calibrator to the field with you during the whole week with 10 calibration procedures stored in the device. Run the procedure after connecting the probes to the instrument (Easy connect system®) and save the results for onsite easy and quick calibration. Back to the office, you can then upload the data on a computer in order to issue customized calibration certificates with dedicated calibration software DATACAL. IP 54, fully protected by an antichoc rubber holster, CALYS 150 integrates "easyconnect" terminals and a wide backlite display that makes it easy to use in any severe or dark conditions. When used with an external pressure module (ref. ACL433), CALYS 150 can measure and simulate pressure (comparison calibration with a pressure pump). CALYS 150 has also the capability to drive baths and dry-blocks when associated with the specific cable (ref. ACL600).Easy connection system Connect your probes by simply pushing on the terminal top and insert wires of up to 3 mm or 10 AWG diameter and compensated thermocouple connectors. Wires are held tight between two brass plates ensuring thermal stability and a very good cold junction compensation for thermocouples. This system also enables 4 mm banana plugs and security connectors to be connected on the terminal top. Specifications CALYS 50 CALYS 75 CALYS 100 CALYS 150 Top accuracy 200 ppm 130 ppm 50 ppm Temperature accuracy Thermocouples (14) RTDs (12) 0.013% RDG for Tc K 0.012% RDG 0.01% RDG for Tc K 0.01% RDG 0.005% RDG for Tc K 0.006% RDG DC current + Loop supply 24 V Range Accuracy 50 mA 0.0175% RDG 100 mA 0.007% RDG DC voltage Range Accuracy 50 V IN / 20 V OUT 0.013% RDG 50 V 0.013% RDG 50 V 0.010% RDG 50 V 0.005% RDG Frequency Range Accuracy 20 KHz IN / 10 KHz OUT 0.005% RDG 100 KHz 0.01% RDG Resistance Range Accuracy 4000 ? 0.012% RDG 4000 ? 0.010% RDG 50 K? 0.006% RDG Pressure Range Accuracy   Relative pressure: 30 bar / Absolute pressure: 1,000 bar 0.05% RDG Compliance to standards       21 CFR Part 11       NADCAP Heat treatment AMS 2750 Additional functions Advanced data exploitation: Scaling, relative measurement, simulation of ramps and steps, synthetizer, square root, statistical functions Transmitter function Additional functions   Switch test Calibration of transmitters Additional functions       Comparison calibration HART: Digital calibration and data transfer Calibration of thermistors Software   DATACAL calibration software for configuration and data management Memory   10,000 data stored and recalled on screen as curve or list

Recommended Products For Aoip


Aoip VENUS Industrical Dry Block Calibrator, Liquid Bath, Blackbody Source & Fixed Point System
Aoip GEMINI R 976 Medium Temperature Primary Blackbody Source
Aoip QUICK-CAL 550-02 Compact Medium Temperature Blackbody Source
Aoip MILLIK Expandable 3-Channel Precision Thermometer
Aoip CALYS 75 Field Documenting Multifunction Calibrator
Aoip OM 10 Portable Micro-Ohmmeter
Aoip EUROPA 6 Temperature Thermometers
Aoip CALYS 50 Field Instruments
Aoip RAYOMATIC 20 Process Infrared Thermometer
Aoip CALYS 75 Field Instruments
Aoip OM 16 Onsite 10 A micro-Ohmmeter
Aoip CP 6632 Handheld Process Signal Calibrator
Aoip ISOPALM 200 Cable Fault Locator
Aoip CALYS 60 IS Field Instruments
Aoip QUICK-CAL 560 Cost-Effective Compact and Fast Dry Block
Aoip PEGASUS R 970 High Temperature Primary Blackbody Source
Aoip EPM Electrical Motor Control
Aoip GEMINI 700 LRI High Capacity Portable Calibration
Moog 761-5051B5 Valve
Air Dimensions E-Series Dia-Vac® Pump Single Head
Enerpac BZ12031 One Shot Pipe Bending Shoe
Enerpac HCL20012 Hydraulic Cylinder
Bollfilter P/N: 116-2500025 Z32284 S/N: 3725754/5 ( For 6.64 DN 200 ) Screwing
Grundfos NK 150-250/262 BA1F1AESBAQERW3 Pump
Asco Joucomatic NFB210C034-24VDC Solenoid Valve
Vogel MKU2-14BC01000 428 Single Line Pump
KSB HPKL125-080-250 EEBS Pump
Wilkerson RRP-96-986
Habasit HAL-12E Belt
Heidenhain 768295-11 ECN 1313 512 62S12-78 K 0,00 Encoder
Anderson Greenwood Y1 TANK BLANKETING REGULATOR
Hengstler AC58/0812ES.41PBB Absolute Encoder
Grundfos 97757693 O-ring
Faggiolati G418R2C2-S80AA2 Pump
SKF SOFN 240 BF Housing Fixed Bearing
Parker 15P102QHBE2KS1221 Duplex Filter
Tapcon 250 Voltage Regulator
IFM NI5003 II-2015-N/1D/1G/2G Inductive NAMUR sensor
Stenflex Type AS-2 DN 65 Expansion Joint
Eaton Vickers (Danfoss) V4051B7C10 Filter Element
Holmatro 18 S 50 E Vari Pump
Alfa Laval 9612628476 LKB F DN65 DIN W/W Q 304L KIT ACT LKLA Ø85 NC 6MM