Product Description
Ascon products, including Ascon Ms-30/099 Temperature Controller, are sourced through parallel import channels and delivered to our customers worldwide with speed and reliability. As an authorized trading partner, Imtek Engineering offers genuine Ascon parts at competitive prices. Even if Ascon Ms-30/099 Temperature Controller is not listed on our website, you are welcome to request a price quote — our team will respond promptly with a tailored offer.
3 • CODIFICATION
Double action (Heat-Cool)
Model Model code
Configuration code
Beginning and end of scale (only for configurable scales)
MS - A B
C D E F
Mains 100…240 V 50/60Hz 18…28V 50/60Hz and 20…30Vdc
A 3 5
G• • • • H
Fitted Ascon std. protocol Fitted Mod/bus/Jbus protocol
Type L Type K
0…600°C 0…1200°C
Type S 4…20mA 0…20mA
0…1600°C Conf. eng. units Conf. eng. units
0…1 Vdc
Conf. eng. units
0…10 Vdc
Conf. eng. units
Pb heat
db
Relay 3A/250 Vac Logic 0/18 Vdc
You can configure your instrument just entering trough the keyboard an 4 characters code
E 0 1 2 3 4 5 6 7 8 9
Type of action and safety state Y1 (2) 0% Reverse Safety On-Off
D 0 1
Output type Y1
Direct
Safety
0%
Reverse Safety Safety
100% 100%
Reverse Safety Direct Safety
0% 0%
Reverse Safety Direct Safety
100%
Reverse Safety Direct Safety
-100%
Direct
100% -100%
Yh2 0% Input X
With r.c.r = relative gain of cool action from 0.1 to 3.0 Example:
if Pb heat = 10% and r.c.r =0.5 Pb cool = 20% The ti (integral) and td (derivative) times of Heat are
valid also for Cool whereas the cycling times tc are different.
Band with inhibition
Band I∆WI
W1
The configuration code indexes C, D, E, F
On Off
Type of Set point and control mode output Y2 Disabled Heat-Cool (2)
Note:
1 For mA and Volt inputs the beginning and end scale values can be configured in
engineering units between -999 and 9999.
The minimum scale span is of 100 steps.
The values can be expressed in units (xxxx), in tenths (xxx.x), hundredths (xx.xx)
or thousandths (x.xxx).
2 The safety value assumed by Y1 and Y2 (if configured heat-cool) in case of failure
in the control loop coincides respectively with the upper limit of Yh and Yh2.
Input X
Pb cool dead zone
100%
P.I.D.
Thermocouples
IEC 584
C 0 1 2 3 4 5 6 7 8 9
: limits Y1 between 10 and 100% : limits Y2 between -10 and -100% : dead zone between 0.0 and 5.0%
Pb heat Pb cool = ———— Set point r.c.r
Yh 0% Y2 cool
Configuration Input type, scale range (1) -200…600°C Pt100
RTD IEC 751 -99,9…300,0°C Pt100 0…600°C Type J
for reverse action (E = 4.6 or 8) for Heat-Cool operation (F=1)
100%
B 0 1 2
Serial communication (option) None
With Y1 configured and Y2 configured you obtain:
Yh Yh2 db Y1 heat
Startup inhibition band Active outside
!
Active outside
Band
If at the power-up appears that means the controller IS NOT CONFIGURED (see instructions)
Active inside Active high
Independent
Active low Active high
Deviation
Active low
Loop - Break - Alarm
F 0 1 2 3 4 5 6 7 8 9
Enabled intervention (at the first exit beyond the band limits after 16 secs. min)
Band I∆WI
Startup
Inhibition
W1
On Off Startup
4 • KEYS AND DISPLAYS
Band I∆WI
Reds
If below beginning of scale
---8888
Keys
• In programmation:
displays parameter values
• In configuration:
displays the values of the configuration code
Keys for modifying values Selects the digit to be modified Increments value of the
flashing digit from 0…9
Displays the Set point value
Programming keys Access to the functions menu
• In programmation:
displays the parameter codes
Enters or Scrolls values or operation modes
active inside H
H I∆WI
I∆WI
300 steps
300 steps
Independent W
On Off active Low H W Beginning of scale
End of scale
"Loop-Break-Alarm" LBA (interruption/control loop failure)
Deviation ∆W
With Y2 output active and configured as Loop-Break-Alarm
On Off active High
W1
Y1
active Low H ∆W -300 steps
+300 steps
mA °C
pressing any key
On Off active High
W1
Green, H7mm
____ 8888
Green, H10mm
Displays the value of measure X expressed in engineering units.
If above end of scale
Lit with output Y1 "ON" Lit with output Y2 "ON"
Any interruption in connections or any failure in the operation of one of
the control loop components will cause after a few minutes the output Y2 to be energized and the entire front
display to flash.
The alarm state stops when the failure having caused it disappears or
On Off active outside
W1
Display
Leds for output states
The Setting range of Y2 is not limited by the limits of main Set point W1 but only by the scale
span