Ayvaz AFBT Flash Vessel Tank Systems

Ayvaz

Product Code: AFBT
Brand: Ayvaz



GET OFFER: info@imtek.com.tr

Description for Ayvaz AFBT Flash Vessel Tank Systems

Things To Be Careful About Choosing Flash Vessel Tank: Saturated steam, which evaporates from the heat transfer surfaces, is converted into condensate at the same pressure. The enthalpy of saturated water at 1 bar pressure is 505 kJ / kg. If the condensate at 6 bar pressure is released by 1 bar the energy output will be 697-505 = 192 kJ / kg. This energy evaporates some of the condensate to steam.This steam is Flash Steam.Why Flash Steam is Important?It includes too much energy and it can be mount to different installation areas.If Flash Steam drains to the atmosphere there will be waste energy and effeciency lost.Acquiring Flash SteamWhen the water is heated under atmospheric pressure, the temperature rises up to 100 °C.The heat to be given does not increase the temperature, but it converts water to steam.The heat absorbed by the water during the rising of the temperature to the boiling point is called "sensible heat" or “saturated liquid heat”. At the same temperature, the heat required to turn the water at the boiling point into steam is called "latent heat".The amount of heat required to increase 1 kg of water temperature by 1 ° C in the atmospheric pressure is 4,186 kJThe saturated liquid temperature of the condensate at steam temperature and pressure of 8 bar is 721 kJ / kg (saturated steam table).If this condensate is leaked to a 2 bar tank, the heat value (saturated liquid temperature) drops to 504 kJ / kg.This is 721-504 = 217 kJ/kg of excess condensate. The percentage of the condensate to be transformed into the steam can be calculated as follows.% Flash Steam = (Q1-Q2 / q) x100Q1: Saturated liquid heat at high pressure before dischargeQ2: Saturated liquid heat of the condensate at low pressureq: The latent heat of the steam at low pressure where the condensate is drained % Flash Steam = (721-504/2201)x100 = 9.6%That is, if there is a condensate of 3000 kg;Flash Steam = 3000x9,6% = 288 kg/hFlash Steam Tanks are used to separate the flash steam from the condensate water.In order for the flash steam to move towards the top outlet at the correct speed, the diameter of the steam tank must be appropriate. This speed is about 3-5 m/s and the velocity at which water droplets can reach the bottom of the tank. In order to be efficient, the condensate inlet to the tank should be one-third of the tank neck below. The diameter of the flash steam tank should be a diameter that allows the passage of the condensate without coming into turbulence.If the difference between high and low pressure is small.The amount of steam is less than the amount of condensate. Flash steam outlet pipe selecting the diameter according to the speed will cause the tank to remain small. in which case the tank must be selected to be two diameters larger.Choosing Flash Vessel1- Maximum condensation amount is required to obtain maximum flash steam.For this reason, the capacity of steam traps must be selected carefully, taking into consideration the counterpressure. It should also be noted that in systems where temperature control valves are used, the valve will be closed and the pressure will drop.2- The amount of use of flash steam systems must be equal to the amount of flash steam.Steam can be provided by pressure drop from a higher pressure steam line when the flash steam is missing. If flash steam is excessive, some of the flash steam must be thrown out. Also, since the flash used in heating will not be needed in summer, a heat recovery system will not be necessary.Therefore, the amount of flash steam required must be prepared.3- It is beneficial if the system to be used with flash steam is close to the outlet of the condensate at high pressure. The transport of low-pressure condensate requires large diameters and will increase investment costs. In addition, the heat losses that will occur on large pipe diameters will reduce the benefits of flash buckets.

Recommended Products For Ayvaz


Ayvaz MG-33 Magnetic Level Gauge
Ayvaz RC-11 Level Gauges with Reflex Glass
Ayvaz SK-50B Bimetallic Float Type Steam Trap (DN-25)
Ayvaz CLV-50 Check Valve
Ayvaz TGV–25 FULL BORE BALL VALVE
Ayvaz HK-23 Steam Trap
Ayvaz TKK-41 Thermostatic Steam Trap
Ayvaz V-3FP Ball Valve
Ayvaz MG-33SV Magnetic Level Gauge
Ayvaz TKK-42 Thermostatic Steam Trap
Ayvaz VK-71 Vacuum Breaker
Ayvaz BC-100 Swing Type Bronze Checkvalve
Ayvaz TGV–10 Full Bore Ball Valve
Ayvaz AECAP Capacitive Level Transmitter
Ayvaz NanoFlex Nano Insulated Hoses for Solar Panel Connection
Ayvaz MG-33S Magnetic Level Gauge
Ayvaz MKDF-30L Axial Type - Lateral Type Expansion Joint
Ayvaz AEFS Magnetic Flow Switch
Hengstler AD36/0022EF.0RSCB Absolute Encoder
Eltra EL63D50Z528P10S ENCODER
Topworx DXP-L21GNEB - 3/4Inch NPT, 304 Stainless Steel NAMUR, Aluminium, Standard 90°, D Series Valve Controller
Gefran LT-B-0175-P 0000X000N0N Potentiometer
Gestra UNA46MAX
Gefran LT-H-0110-S 0000X000X00 Potentiometer
Gefran LT-H-1000-P 0000X000X00 Potentiometer
Hengstler RI58-O/10000ES.41IB Encoder
Kadant 9940180/0002 SX Rotary Joint
Gefran LT-H-0450-P L000X000B0N Potentiometer
Winsmith U3040S14 RD Speed Reducer
Elwa 848WR-V Tank Heater
Bollfilter 550002 Pressure Indicator
Koso 600B Butterfly Valves Casting Body type
Festo VMPA2-M1H-K-PI Selenoid Valve Festo VMPA2-M1H-K-PI Selenoid Valve
Gefran LT-H-0650-P L000X000B0N Potentiometer
Ringfeder RfN 7014 Locking Assembly
Alfa Laval 9612628661 LKB F DN80 DIN W/W EPDM 304L KIT ACT LKLA-T Ø85 NC 6MM
Eaton HDD151-0006 Duplex Filter
Kadant 995.423/0003 RX Rotary Union
Elma A47 Remote Audio Plus
Lamtec F130I Flame Monitoring Device
Gefran LT-M-1100-S L000X000B00 Potentiometer
Meidinger 140-9 Blower