im-tek.com

Ayvaz DBV-10 Boiler Automatic Bottom Blowdown System

Ayvaz

Product Code: DBV-10
Brand: Ayvaz



GET OFFER: info@imtek.com.tr

Description for Ayvaz DBV-10 Boiler Automatic Bottom Blowdown System

The formation of hard accumulation in boilers (stone and mud ) is caused by some impurities and corrosion products contained in water. Examples of water impurities are; dissolved calcium, magnesium chloride, sulfate and silicon elements; Examples of corrosion products include iron and copper. The water impurities in the boiler consist of condensate leaks and boiler feed water (make-up); Corrosion products, as a result of corrosion, also comes from the condensate and feed water.Deposits cause a waste of fuel in the boiler, a slight decrease in productivity, and more importantly, overheating occurs metal annealing and pipe explosion. The boiler zone where the accumulation causes the biggest problem is the evaporator pipes around the burners in the combustion chamber. The system that is used to prevent the problems caused by these hard accumulation compounds and to expurge hard materials from the boiler is called Boiler Automatic Bottom Blowdown SystemsACCUMULATION (STONE) TYPESCalcium carbonate (the most common type of stone), calcium sulfate, silica, phosphate stones, magnesium and magnesium stones, aluminum, iron oxides (usually in the boiler and condensate line is the product of corrosion).ACCUMULATION EFFECTSReduced thermal conductivity: stones are poor heat conductors and act as insulators as indicated by the various conductivity values. The resulting furring layer causes the reduction of steam generation. In addition, the resulting furring layer increases the fuel consumption and increases the unit cost of steam generation.Temperature build-up in the metal wall: As a stone-coated wall prevents heat transfer, the wall temperature rises. This is called overheating and the metal may lose some of its mechanical properties (elasticity, etc.). These cause local shape disturbances and cause pipe explosion.Blowdown Systems Components-BLOWDOWN VALVE V-3F-Body and Cover : AISI 304 Stainless Steel(Opt. AISI 316) Working Temperature : -50 / +210°CPressure Class : PN40

Recommended Products For Ayvaz


Ayvaz TDK-45 DN25 PN16 Thermodynamic Condenser
Ayvaz 708030522060 Valve
Ayvaz AECAS Capacitive Level Switch
Ayvaz SC-201 Check Valve
Ayvaz MG-33P Magnetic Level Gauge
Ayvaz SK-51 Mechanical Steam Trap
Ayvaz MV-417 Manometer Valve
Ayvaz Boiler Flex Flexible Metal Hose
Ayvaz MG-33S Magnetic Level Gauge
Ayvaz KV-10 Butterfly Valve
Ayvaz V-2FP DN15 PN40 AISI316 Quality Stainless Valve
Ayvaz DN100 PN16 DBKF-60 Compensator
Ayvaz MK-25 Bellow Sealed Stop Valve
Ayvaz CV-35 Check Valve
Ayvaz CV10/S2 Check Valve
Ayvaz CV10/S1 Check Valve
Ayvaz HA-50 Air Eliminator
Ayvaz MGK-33 DN20 PN16 WITH FLANGE Magnetic Level Indicator
Metalwork 6169004UA V3V 400 SOL. PILOT-ASSISTED W/END PLATES
Atlas Copco IRTT-B75A-10 Transducer
Eaton 319346 Eaton 01.nl In-line Filter Elements
Alfa Laval 9612943224 VALVE LKB-2 DN80 DIN W/W PFA 316L
Böhmer FZL V 063.065-2 065 063 Ball Valve
Atos FV JO-DL-4-2/FV-X 24DC Valve
Atlas Copco 2901109500 Therm. + Mpv Kit C40
Vibro Meter 111-402-000-013-A2-B6-C064-D000-E010-F0-G000-H05 Type: Tq402
Gestra CB26 DN80 PN40 Seal Epdm With Spring
Adalet XJF-121206 Explosion Proof Control Enclosures
Ebara CMB 1.00 T Centrifugal Pump
Gat ESW 300 Slip Rings
Samson 6111 0,4…2 bar Converter
Emotron VSX48-004-20CEB Drive
Bollfilter 3096995 Seal kit
Eaton 829AN00146A DG4V-5-2CJ-VM-U-H7-22 Valve
Wandfluh AH4D61 a/r - S127 1 Valve
Gemü 514 40SVS 5 88233441 Seal Kit
Faggiolati X216R2H3-P40LA5 Pump
Bucher Hydraulics LRV175 - 134.0/134.0 - 25.0/35.0 Lift Control Valve
RSF Elektronik MS 3x.x3 MK Lineer Cetvel Singtronic Encoder
Grundfos MTR 20-5/5 D-M-A-AQQV Immersible Pump
Bucher Hydraulics DWPA-2-10-SM10-2 Pressure Shut-off Valve
Kaeser 901531.0 Filter Element