Need Help? Chat with us on WhatsApp - We're here to assist you!
FAST DELIVERY FROM GERMANY TO WORLDWIDE
bucher-100023535-internal-gear-pump-qt62-125-52-040r206-4_909169.jpg
bucher-100023535-internal-gear-pump-qt62-125-52-040r206-4_909169.jpg

Quantity :

Request an Offer

97% customer satisfaction based on last 45 days of sales

BUCHER 100023535 Internal Gear Pump QT62-125/52-040R206-4

Ask for Stock

Brand:
Product Code:
100023535 Internal Gear Pump QT62-125/52-040R206-4

Order Processing & Delivery Information:
As we supply industrial equipment, product availability and delivery timelines may vary. Once your order is placed, our sales team will contact you within 24 business hours (excluding weekends and holidays) to confirm stock status and estimated delivery time.



🎯 Need a Quote for BUCHER 100023535 Internal Gear Pump QT62-125/52-040R206-4?

Get the best price and fastest delivery for BUCHER 100023535 Internal Gear Pump QT62-125/52-040R206-4 from BUCHER. Imtek Engineering offers worldwide industrial equipment supply with expert support.


Details:
Artikel: 100023535





































































General
characteristics



Unit



Description,
Value



Installation
attitude



 



unrestricted



Mounting
method (standard)



 



oval 2-hole flange to ISO 3019/1
(SAE): QX 3-6 oval 2-hole flange to ISO 3019/2 (metric): QX 2+8



Direction
of rotation



 



CW
or CCW



Pump
drive method



 



in-line,
through a flexible coupling



Volumetric
efficiency hv



 



up
to 98%



Fluids



 



HLP mineral oils to DIN 51524 Part
2, HFC fluids to VDMA 24317



Maximum admissible level of
contamination of the hydraulic fluid



 



ISO
4406 code 20/18/15 (see section 9)



Operating viscosity Starting
viscosity



mm2/s



10
… 100 *


10
… 300 * *other values on request



Fluid
temperature range



°C



HLP-mineral oils -20 min. / +80 max.
/ HFC +50 max. range for max. long life cycle +30 …
+60 (considering viscosity field)



Inlet
pressure maximum


minimum



bar



1.5
absolute (without external drain connection)


0.5 … 0.98
absolute (dependent on pump frame size and speed, see example in section
3.3.2)



Startup
against pressure



bar



max.
20 (other values on request)



Seal
material



 



NBR
= standard / FPM (Viton) = option 09