Product Name: Greisinger GCO100 Compact CO-Measuring Device
Brand: Greisinger
Product Code: GCO100
Tags: Greisinger
GCO100
Greisinger GCO100 CO-Measuring
Greisinger Compact
Greisinger Compact CO-Measuring
Greisinger CO-Measuring Device
GCO100 CO-Measuring Device
Greisinger GCO100 Compact CO-Measuring Device
Greisinger GCO100
GCO100 Compact Device
Greisinger GCO100 Compact Device
Greisinger Compact Device
GCO100 Compact
Greisinger Compact CO-Measuring Device
CO-Measuring
GCO100 Device
Greisinger GCO100 CO-Measuring Device
GCO100 CO-Measuring
Compact CO-Measuring Device
Compact CO-Measuring
Artikel: 600062
Compact CO-Measuring Device
您对制造商Greisinger的产品Greisinger GCO100 Compact CO-Measuring Device,代码为GCO100感兴趣吗?立即联系我们获取报价。Imtek Engineering,世界上最快最可靠的工业设备供应商,将为您提供最佳报价!
Get Offer With E-Mail: info@im-tek.com
Get a offer for Greisinger GCO100 Compact CO-Measuring Device from our live support team now!
CO-measuring device with alarmHIGHLIGHTS:3 display units selectable (ppm, mg / m³ and% CO Hb)Alert at exceeding the maximum concentration at work (MAK / AGW)including interfaceincl. calibration protocolGENERAL:Carbon monoxide (CO) is created by the combustion of carbon. Depending on the effectiveness of the combustion (oxygen supply) and the temperature of the combustion more or less CO gas is created. The gas is inflammable and highly toxic. It is invisible, tasteless and scentless.Even smallest concentrations are dangerous for humans!Therefore a directive exists in Germany, which limits the maximum concentration of CO gas at work (MAK / AGW) to 30 ppm.APPLICATION:Control of the air quality (eg at work place)Checking of heating systems, gas central-heating, fireplaceControl of the air at maintenance work (tunnel, flue gas tract, ...)Detection of CO in the breath of smoker (% CO Hb)Cognition of CO poisoning ie at burnt offering (fire fighters, ...)SPECIFICATIONS:Measuring principle:electrochemical CO measuring cellMeasuring range:0 ... 1000 ppm CO concentrationDisplay ranges:0 ... 1000 ppm CO concentration0 ... 1250 mg / m³ CO concentration0 ... 60.0% CO Hb (estimation via exhaled breath gas)Resolution:1 ppm, 1 mg / m³ or 0.1% CO HbSensor element:integrated in device, measuring inlet at front plate, with inner thread for accessories screw inLife time:> 5 years at proper usage at air suggested test interval: every 6 months (depending on precision requirements)Accuracy: (at range 0 ... 500 ppm)Linearity:<± 5% of measured value ± 1 digitRepeatability:<± 5% of measured value ± 1 digitscope of supply:device, battery, calibration protocol, manual