im-tek.com

Anderson Greenwood ERQS Flame Arrester

Anderson Greenwood

Product Code: ERQS
Brand: Anderson Greenwood



GET OFFER: info@imtek.com.tr

Description for Anderson Greenwood ERQS Flame Arrester

1. GENERAL ERQ series vent flame arresters are intended for low-pressure venting applications where the maximum differential pressure across the flame arrester does not exceed 1 barg. 2. GUIDANCE 1. Maximum temperature limit is -20° to +60°C (+200°C for certain gas groups - see special conditions for safe use). 2. Mounting of all monitoring devices shall be in accordance with EN 50018. 3. Flame arresters should not be positioned near hot equipment unless certified for the elevated temperature as heat transfer to the flame arrester will reduce its performance and may cause it to fail. 4. Shut-off devices should be fully open during normal operation. 5. Continuous monitoring of pressure drop is advised if the process is known to contain particulates or substances which can block the element and over-pressurize the system. 6. Metal parts insulated by gaskets should be earthed where necessary. 7. Flame velocities and pressures of flammable mixtures can be enhanced by upstream turbulence, which can be caused by bends, valves or any change in section of the pipework. The flame arrester should only be used for the process application; if the process conditions or the pipework configuration change the flame arrester should be checked with the manufacturer. 8. ERQ series vent flame arresters are designed to prevent external fires/ explosions igniting flammable gases/ vapors within vent piping and associated equipment. They are NOT designed to prevent internal explosions passing to atmosphere. 9. ONLY install for applications for which they have been designed and specified - refer to product data sheet for guidance. It is potentially dangerous to use in other applications.3. INSTALLATION Remove all packaging from the flame arrester prior to installation, paying particular attention to the area between the flame arrester element and weather cover. Mount the flame arrester vertically upright at the end of the vent line: (i) Flanged connection - bolt to a flange of the same specification as that fitted to the flame arrester itself, with an intermediate gasket of a type appropriate to the service conditions. Tighten the bolting uniformly to ensure a good seal. (ii) Screwed connection - fit to the corresponding male/female thread. Sealing tape or sealant may be used to ensure a good seal.

Recommended Products For Anderson Greenwood


Anderson Greenwood H7HP Hand Valve
Anderson Greenwood MDP Differential Pressure Manifold
Anderson Greenwood Instrumentation Model M3A Differential Pressure Manifolds Differential Pressure Manifold
Anderson Greenwood A230 Differential Pressure Manifold
Anderson Greenwood M4AP Differential Pressure Manifold
Anderson Greenwood Marvac 785 emergency relief manhole cover
Anderson Greenwood Marvac 600 Pressure Relief Valve
Anderson Greenwood 4410 Side Entry Atmospheric Vacuum Relief Valve
Anderson Greenwood Amal IRQ In­line Deflagration Flame Arrester
Anderson Greenwood M25B Manifold
Anderson Greenwood RA TANK BLANKETING REGULATOR
Anderson Greenwood Amal NPC Flame Arrester
Anderson Greenwood ERQ Flame Arrester
Anderson Greenwood F64 Isolation Valve
Anderson Greenwood HM25D Hand Valve
Anderson Greenwood 5200 Pilot Operated Pressure Relief Valve
Anderson Greenwood 4020 Atmospheric Pressure and Vacuum Valve
Anderson Greenwood Whessoe 4110A vacuum relief valve
Turbo TM030(N-V-T)M Flanged Straight Through Valves
NSD VARICAM VS-5F Cam Switch Output Controller
KSB MCPK050-032-160 EC NP2 A Pump
Faulhaber 22/7 66:1 Planetary Gearhead
Eaton FAZ-C16/1 Miniature Circuit Breaker
American Industrial SAE-1204-FP Heat Exchanger
Stauff PSCFTP5 PIASTRA SUPERIORE PER CFTP5
Helmholz LED 700-972-7BB51 Profibus Connector
Faggiolati G609T2C1-P80AA6 Pump
Hoyer 5520801109 IE3 Electric Motor
American Industrial AA-1672-TP Heat Exchanger
Ringspann RLK402 45x75 Clamping Element From Ringspann
Elomatic 11462 F600 Square 27mm Drive Insert
Control Techniques SP 5402 75/90KW Ac Motor Driver
Goldammer IND-GB-111, Indicator - L - 1 - R (remote installation), Level controller with PNP level outputs
Gemü Gemü 807R20D 72214 147 400 Variable Area Flowmeter
Dropsa 0671300 AG6-VALVOLA 2 USC Q=0,25 -3 Distributor
Metalwork 3671001U APR 200 1/2 SOLENOID
Knf NMP0151.2XPDC-S Micro Diaphragm Gas Pump
Mollet MFB-EA Membrane Level Indicator
Böhmer FSL V 016.025 Ball Valve
Vaisala MGP261 Multigas Probe
Eaton Vickers (Danfoss) 864AN00004A KBHDG5V-5-2C95N-X-M1-PE7-H4-12 Proportional Two Stag
Vogel 288968 Reducer