im-tek.com

Dynisco ECHO-MV3-MPA-R21-UNF-6PN-S06-NFL-NTR Melt Pressure Transducers

Dynisco

Product Code: ECHO-MV3-MPA-R21-UNF-6PN-S06-NFL-NTR Melt Pressure Transducers
Brand: Dynisco



GET OFFER: info@imtek.com.tr

Description for Dynisco ECHO-MV3-MPA-R21-UNF-6PN-S06-NFL-NTR Melt Pressure Transducers

·         2 year warranty and 60 years of Dynisco industry experience·         Accuracy better than ±0.5%·         TiAlN diaphragm coating is standard·         mV/V, 0-10VDC, or mA outputs available·         Integral temperature sensor option·         Available in configurations that fit most extruder applications·         1.5M, 3M, 5M, 7.5M & 10M psi pressure range capability·         Alternative fill model available  Operating Principle The Dynisco EchoTM Melt Pressure Sensors are used to make pressure measurements of molten polymers up to 752°F (400°C). These models incorporate a 350?Ohm, bonded foil strain gage Wheatstone Bridge. This proven technology provides an output of 0?3.33 mV/V, & 4?20mA, 05?VDC and 0?10VDC proportional to melt pressure (within the specified error band). Most models include an internal shunt calibration ("Rcal") function that is used to simulate a signal of 80% of full scale. This eliminates the need for a cumbersome calibrated pressure source when scaling associated instrumentation. Installation Do not remove protective cap until ready to install. Prior to initial installation, verify correct machining of mounting hole per Figure 1. Gauge Plug, P/N 200908, is available for this purpose. Before installing make sure that mounting hole is clear of material. Dynisco Cleaning Tool Kit, P/N 200100, should be used. To prevent galling, lightly coat transducer threads with a high temperature anti?seize material. An adequate seal, in a properly machined and maintained mounting well, is obtained with 100 in?lbs. mounting torque. The maximum torque recommended is 500 in?lbs. The electronics housing should be secured, with the optional mounting bracket (P/N 200941), in an area where the ambient temperature will not exceed 185°F (85°C). (Mounting bracket not supplied with EchoTM models.)Wiring Use shielded cable. Attach cable shield to ground at one end only. NOTE: DYNISCO cable assemblies are constructed with shield wired to transducer mating connector, so do not attach shield to instrument. Output Supply Voltage mV/V 10 Vdc (12 Vdc max) mA 14?36 Vdc Vdc 16?36 Vdc Start?Up Bring system to operating temperature with no pressure. For mA units, remove adjustment access screw and adjust Zero Output potentiometer. For mV/V units, zero adjustment must be handled by downstream indicator. Make sure that there is sufficient "soak time" to assure that any material at the tip of the transducer is molten before extruder drive is started. Removal Transducer should only be removed when polymer is hot and liquid. Wipe tip with a soft cloth immediately. The melt pressure transducer must be removed before using an abrasive material or wire brush to clean the extruder barrel. Clean the mounting well before attempting to reinstall the transducer with Dynisco Mounting Well Cleaning Tool Kit, P/N 200100. Thermocouple Thermocouples ( Type J or K) in a rigid stem are optionally available. The Type J (iron?constantan) and Type K is a T/C junction just behind the flush diaphragm at the tip of the transducer. For the most accurate temperature measurement of the melt stream, use a separate immersion?type thermocouple, such as Dynisco TB422 fixed depth series or (G)RMT adjustable models. The thermocouple assembly can be removed by loosening the set screw on the side of hex assembly and pulling the T/C probe, carefully, straight out, without twisting. Replacement assemblies are available. When installing the thermocouple probe assembly, align the slot with the pressure capillary tube and press into snout until top of probe shoulders flush against snout. Lock in place with set screw.Warranty This Dynisco product is warranted under terms and conditions set forth in the Dynisco Web Pages. Go to www.dynisco.com and click on “Warranty” at the bottom of any page for complete details.  

Recommended Products For Dynisco


Dynisco UPR90030000000 Process Indicator
Dynisco PT462E-M18-5M-6/18 Pressure Sensors
Dynisco PT 4624-35MPA-6/18 Pressure Sensors
Dynisco VERT-MV3-MM1-NDC-PSI-R17-UNF-6PN-S06-NFL-NTR-NCC Melt Pressure Sensor
Dynisco 2291NA48K13BUMMACAZZ Pressure Sensors
Dynisco MDT462F-1/2-5C-15/46 Melt Pressure Transmitters
Dynisco MDT462F-1/2-2C-15/46-A Melt Pressure Transmitters
Dynisco IDA354-5c-10V-S78 Pressure Transmitters
Dynisco IDA354-3,5C-10V-S78B Pressure Transmitters
Dynisco ECHO-MV3-PSI-R21-UNF-6PN-F30-NTR Melt Pressure Transducers
Dynisco TPT463E-1/2-10M-6/18 Pressure Sensors
Dynisco MDT422F-1/2-2C-46/46-SIL2 Melt Pressure Transmitters
Dynisco PT460H-3 Pressure Sensors
Dynisco IDA 374-1 5C-D06 Pressure Transmitters
Dynisco 462200000292 Pressure Sensor
Dynisco IDA353-3.5C-0-5V Pressure Transmitters
Dynisco MDT462F-1/2-3.5C-32/46A Melt Pressure Transmitters
Dynisco PT4624-20MPA-6/18-SIL2 Pressure Sensors
Honeywell HYDRANAL™ - Solver (Crude) Oil 34697 Fluka
Olaer SACCA C/IMB 50LCED22-1/2" "20UNF+valv ted Bladder
Eaton PKZM0-4-EA Protective Motor Switch
SKF 7228 BCBM Bearing
Habasit APH200PLFS Heavy Conveyor Belt
Alfa Laval 9612220043 NON-RETURN VALVE LKC-2-DIN-W- DN50-EPDM-304
Dynisco TPT463E-1/2-1M-6/18-M956 Pressure Sensors
Moog D633-472B-R04KO1F0VSX2 Valve
Martens ST500 EX-10-0 İsolating Converter
Atlas Copco 3001160216 Kit Prev. Maint. Rxd 55-75vsd+
Armatury K91.4 Ball Valve
Gamak AGM2E 80 2b Motor
Bollfilter 5376612 Bearing Bush
Boschert STO 30-40 TYPE C Gripper
Tinker Rasor SR-2 Soil Resistivity Meter
Alfa Laval 9612402706 VALVE LKB F DN80 DIN W/W EPDM 316L
Grundfos NK 40-225/158 AG1F1S3ESBQQELW1 Pump
Hansa-TMP 1SM 042 Gear Motors
Reich Type AC…F2 DS ARCUSAFLEX ® Highly Flexible Coupling
Atlas Copco 1624433380 Sensor
Schlick Model 0/64-0/60 External Mixing
Aron ADB3E16EK003 ADB3E Cetop 03 valve 4/2 AC Coil
Stenflex Type SA-13 DN 500 Expansion Joint
Metalwork 4480001UA FIL 300 5 RMSA WITHOUT END PLATES