im-tek.com

Dynisco ECHO-MV3-PSI-R21-UNF-6PN-S06-F30-NTR Melt Pressure Transducers

Dynisco

Product Code: ECHO-MV3-PSI-R21-UNF-6PN-S06-F30-NTR Melt Pressure Transducers
Brand: Dynisco



GET OFFER: info@imtek.com.tr

Description for Dynisco ECHO-MV3-PSI-R21-UNF-6PN-S06-F30-NTR Melt Pressure Transducers

·         2 year warranty and 60 years of Dynisco industry experience·         Accuracy better than ±0.5%·         TiAlN diaphragm coating is standard·         mV/V, 0-10VDC, or mA outputs available·         Integral temperature sensor option·         Available in configurations that fit most extruder applications·         1.5M, 3M, 5M, 7.5M & 10M psi pressure range capability·         Alternative fill model available  Operating Principle The Dynisco EchoTM Melt Pressure Sensors are used to make pressure measurements of molten polymers up to 752°F (400°C). These models incorporate a 350?Ohm, bonded foil strain gage Wheatstone Bridge. This proven technology provides an output of 0?3.33 mV/V, & 4?20mA, 05?VDC and 0?10VDC proportional to melt pressure (within the specified error band). Most models include an internal shunt calibration ("Rcal") function that is used to simulate a signal of 80% of full scale. This eliminates the need for a cumbersome calibrated pressure source when scaling associated instrumentation. Installation Do not remove protective cap until ready to install. Prior to initial installation, verify correct machining of mounting hole per Figure 1. Gauge Plug, P/N 200908, is available for this purpose. Before installing make sure that mounting hole is clear of material. Dynisco Cleaning Tool Kit, P/N 200100, should be used. To prevent galling, lightly coat transducer threads with a high temperature anti?seize material. An adequate seal, in a properly machined and maintained mounting well, is obtained with 100 in?lbs. mounting torque. The maximum torque recommended is 500 in?lbs. The electronics housing should be secured, with the optional mounting bracket (P/N 200941), in an area where the ambient temperature will not exceed 185°F (85°C). (Mounting bracket not supplied with EchoTM models.)Wiring Use shielded cable. Attach cable shield to ground at one end only. NOTE: DYNISCO cable assemblies are constructed with shield wired to transducer mating connector, so do not attach shield to instrument. Output Supply Voltage mV/V 10 Vdc (12 Vdc max) mA 14?36 Vdc Vdc 16?36 Vdc Start?Up Bring system to operating temperature with no pressure. For mA units, remove adjustment access screw and adjust Zero Output potentiometer. For mV/V units, zero adjustment must be handled by downstream indicator. Make sure that there is sufficient "soak time" to assure that any material at the tip of the transducer is molten before extruder drive is started. Removal Transducer should only be removed when polymer is hot and liquid. Wipe tip with a soft cloth immediately. The melt pressure transducer must be removed before using an abrasive material or wire brush to clean the extruder barrel. Clean the mounting well before attempting to reinstall the transducer with Dynisco Mounting Well Cleaning Tool Kit, P/N 200100. Thermocouple Thermocouples ( Type J or K) in a rigid stem are optionally available. The Type J (iron?constantan) and Type K is a T/C junction just behind the flush diaphragm at the tip of the transducer. For the most accurate temperature measurement of the melt stream, use a separate immersion?type thermocouple, such as Dynisco TB422 fixed depth series or (G)RMT adjustable models. The thermocouple assembly can be removed by loosening the set screw on the side of hex assembly and pulling the T/C probe, carefully, straight out, without twisting. Replacement assemblies are available. When installing the thermocouple probe assembly, align the slot with the pressure capillary tube and press into snout until top of probe shoulders flush against snout. Lock in place with set screw.Warranty This Dynisco product is warranted under terms and conditions set forth in the Dynisco Web Pages. Go to www.dynisco.com and click on “Warranty” at the bottom of any page for complete details.  

Recommended Products For Dynisco


Dynisco PT160-4M-H88 Pressure Sensors
Dynisco ATC990202011010 Process Controller
Dynisco PT4624-15M-12/18-SIL2 Pressure Sensors
Dynisco MDT462H-1/2-5C-15/46 Melt Pressure Transmitters
Dynisco PT160-5C Pressure Sensors
Dynisco MDT462F-1/2-3,5C-15/46-SIL2 Melt Pressure Transmitters
Dynisco PT-242FM-20MPA-6 Pressure Sensors
Dynisco MDA460-1/2-1M-15 Pressure Sensors
Dynisco 1490-2-1-1-0-0 Panel Indicator
Dynisco VERT-MA4-MM1-NDC-BAR-R23-UNF-6PN-SO6-F18-NTR-NCC Melt Pressure Sensor
Dynisco PT4626-1/2-35MPA-6/18 Pressure Sensors
Dynisco TDT463L-1/2-7C-15/46 Pressure Sensors
Dynisco SPX2242-E-M-00-B-20-DP Pressure Sensors
Dynisco UPR90031100100 Process Indicator
Dynisco MDT462H-1/2-7C-15/46-B106-D85 Melt Pressure Transmitters
Dynisco MDT462F-1/2-3.5C-15/91-SIL2 Melt Pressure Transmitters
Dynisco ECHO-MV3-MPA-R21-UNF-6PN-S06-NFL-NTR Melt Pressure Transducers
Dynisco ATC990-401111000 Process Controller
Winsmith 3000T Triple Reduction Worm Gear
Elma FMC Mezzanine Front Panel
Enerpac RC106 General Purpose Hydraulic Cylinder
Moog G772K620A Servo Valve
Dynisco ECHO-MA4-MPA-R21-M14-6PN-S06-F18-NTR Melt Pressure Sensors
Ascon Z31A Keyboard
Mp Filtri MPF1002AG3P01 Filter Element
Bollfilter P/N: 3040115 O-ring
Stauff SPAL-7076.1-PA-DPAL-AS-M-W10 Clamp Combination
Delta OHM HD 32.3 WBGT PPD PMV Datalogger
Kelvion GWH 700L Brazed Plate Heat Exchangers
Ebara 80-160/15R Centrifugal Pump
Sibre SHI 281 FC Safety Brake with Console
KSB ETNY125-100-250 SGSDT25LA3 B Pump
Turbo TS035(N-V-T)PWE Pulse Valve for Flat Surfaces
Faulhaber 2622S012B SC 207:1 Brushless DC-Gearmotor
MBS MLW 100 4 25 1 3000 Sanitary Mixflo Multitube
LRE XDL-7000 Ignition Cable
Ebro-Armaturen Z 014-A Resilient Seated Valves
Böhmer FSK R 016.300 Ball Valve
Enerpac H7220 Hose
Stahl 9419/08F-LD1-01E1 Linking Device
Mls Lanny Dome pressure reducer DDM0051 D0n A0m
Amg Pesch SAD-180°-33 Double-Piston Quarter Turn Actuator