im-tek.com

Dynisco ECHO-MV3-PSI-R21-UNF-6PN-S06-F18-NTR Melt Pressure Transducers

Dynisco

Product Code: ECHO-MV3-PSI-R21-UNF-6PN-S06-F18-NTR Melt Pressure Transducers
Brand: Dynisco



GET OFFER: info@imtek.com.tr

Description for Dynisco ECHO-MV3-PSI-R21-UNF-6PN-S06-F18-NTR Melt Pressure Transducers

·         2 year warranty and 60 years of Dynisco industry experience·         Accuracy better than ±0.5%·         TiAlN diaphragm coating is standard·         mV/V, 0-10VDC, or mA outputs available·         Integral temperature sensor option·         Available in configurations that fit most extruder applications·         1.5M, 3M, 5M, 7.5M & 10M psi pressure range capability·         Alternative fill model available  Operating Principle The Dynisco EchoTM Melt Pressure Sensors are used to make pressure measurements of molten polymers up to 752°F (400°C). These models incorporate a 350?Ohm, bonded foil strain gage Wheatstone Bridge. This proven technology provides an output of 0?3.33 mV/V, & 4?20mA, 05?VDC and 0?10VDC proportional to melt pressure (within the specified error band). Most models include an internal shunt calibration ("Rcal") function that is used to simulate a signal of 80% of full scale. This eliminates the need for a cumbersome calibrated pressure source when scaling associated instrumentation. Installation Do not remove protective cap until ready to install. Prior to initial installation, verify correct machining of mounting hole per Figure 1. Gauge Plug, P/N 200908, is available for this purpose. Before installing make sure that mounting hole is clear of material. Dynisco Cleaning Tool Kit, P/N 200100, should be used. To prevent galling, lightly coat transducer threads with a high temperature anti?seize material. An adequate seal, in a properly machined and maintained mounting well, is obtained with 100 in?lbs. mounting torque. The maximum torque recommended is 500 in?lbs. The electronics housing should be secured, with the optional mounting bracket (P/N 200941), in an area where the ambient temperature will not exceed 185°F (85°C). (Mounting bracket not supplied with EchoTM models.)Wiring Use shielded cable. Attach cable shield to ground at one end only. NOTE: DYNISCO cable assemblies are constructed with shield wired to transducer mating connector, so do not attach shield to instrument. Output Supply Voltage mV/V 10 Vdc (12 Vdc max) mA 14?36 Vdc Vdc 16?36 Vdc Start?Up Bring system to operating temperature with no pressure. For mA units, remove adjustment access screw and adjust Zero Output potentiometer. For mV/V units, zero adjustment must be handled by downstream indicator. Make sure that there is sufficient "soak time" to assure that any material at the tip of the transducer is molten before extruder drive is started. Removal Transducer should only be removed when polymer is hot and liquid. Wipe tip with a soft cloth immediately. The melt pressure transducer must be removed before using an abrasive material or wire brush to clean the extruder barrel. Clean the mounting well before attempting to reinstall the transducer with Dynisco Mounting Well Cleaning Tool Kit, P/N 200100. Thermocouple Thermocouples ( Type J or K) in a rigid stem are optionally available. The Type J (iron?constantan) and Type K is a T/C junction just behind the flush diaphragm at the tip of the transducer. For the most accurate temperature measurement of the melt stream, use a separate immersion?type thermocouple, such as Dynisco TB422 fixed depth series or (G)RMT adjustable models. The thermocouple assembly can be removed by loosening the set screw on the side of hex assembly and pulling the T/C probe, carefully, straight out, without twisting. Replacement assemblies are available. When installing the thermocouple probe assembly, align the slot with the pressure capillary tube and press into snout until top of probe shoulders flush against snout. Lock in place with set screw.Warranty This Dynisco product is warranted under terms and conditions set forth in the Dynisco Web Pages. Go to www.dynisco.com and click on “Warranty” at the bottom of any page for complete details.

Recommended Products For Dynisco


Dynisco PT462E-5M-6/18 Pressure Sensors
Dynisco PT4624-35MPA-6/18-SIL2 Pressure sensors
Dynisco PT-242FM-50MPA-6/30 Pressure Sensors
Dynisco ECHO-MV3-BAR-R21 Melt Pressure Transducers
Dynisco TPT463E-10M-6/18 Pressure Sensors
Dynisco MDT420F-1/2-5C-15-SIL2 Melt Pressure Transmitters
Dynisco ATC 770-0-3-3 Process Controller
Dynisco 224000000000 Pressure Sensors
Dynisco MDT462F-1/2-5C-15/46-A Melt Pressure Transmitters
Dynisco PT130-3M Pressure Sensors
Dynisco PT160A-4M-H88 Pressure Sensors
Dynisco TPT463E-1/2-10M-6/18 Pressure Sensors
Dynisco TPT463E-1/2-7,5M-6/18 Pressure Sensors
Dynisco TPT4634-1/2-5M-6/18-SIL2 Pressure Sensors
Dynisco UPR900-3-1-0-0-0-0-0-0 Process Indicator
Dynisco MDT462F-M18-7C-15/46-SIL2 Melt Pressure Transmitters
Dynisco TPT432A-3M-6/18 Pressure Sensors
Dynisco PT482-1/2-15M-6/18-B379 Pressure Sensors
Grundfos 96939613 Kit, Wear Ring
Abo Valve GEARBOX WITH HANDWHEEL - 599 B DN80
SKF 6303-2RS Ball Bearing
Weber 3205.1x s310/45 switch
SKF Lincoln CLP-XGXXX2- 0000022 Lubrication Pump
Skf type: LAOS 63595 Drum
Hansa-TMP HMB 400 Axial Piston Motors
Aeco FT18AR FT18/AR 20-250VAC FOTOCELLULA
SKF SRB 22312-CC-K-W33/C3 Bearing
Ru-Steel AGG 5 Elastics
Atos DHA-0631/2/A-M/FI-NC 24DC Valve
Bollfilter BK-1980412 Dublex Filter
Vulcanic 3120-07 Screw Plug Immersion Heater
Eltra EL63AM550Z5/28P10X6MR Encoder
Stahl 8146/5-V11-400-00-0050 Load Disconnect Switch
Elcis 72 I05 - Series for motors
AEP LDT Displacement Transducer
Rotork HPU/A913 Si Pro Bluetooth Setting Tool
Imtron MU500EX Universal Measuring Transducer
Gestra URB1
Gemü Gemü 8258 15 D 1 12 2 1 24= 6005 Valve
Robert Shaw 366-A0 Vibration Switch
Bollfilter 3533821 Rubber Sealing Ring (viton)
Elwa KVE-22,5 Preheater