im-tek.com

Dynisco ECHO-MV3-BAR-R17-UNF-6PN-S06-F18-NTR Melt Pressure Transducers

Dynisco

Product Code: ECHO-MV3-BAR-R17-UNF-6PN-S06-F18-NTR Melt Pressure Transducers
Brand: Dynisco



GET OFFER: info@imtek.com.tr

Description for Dynisco ECHO-MV3-BAR-R17-UNF-6PN-S06-F18-NTR Melt Pressure Transducers

·         2 year warranty and 60 years of Dynisco industry experience·         Accuracy better than ±0.5%·         TiAlN diaphragm coating is standard·         mV/V, 0-10VDC, or mA outputs available·         Integral temperature sensor option·         Available in configurations that fit most extruder applications·         1.5M, 3M, 5M, 7.5M & 10M psi pressure range capability·         Alternative fill model available  Operating Principle The Dynisco EchoTM Melt Pressure Sensors are used to make pressure measurements of molten polymers up to 752°F (400°C). These models incorporate a 350?Ohm, bonded foil strain gage Wheatstone Bridge. This proven technology provides an output of 0?3.33 mV/V, & 4?20mA, 05?VDC and 0?10VDC proportional to melt pressure (within the specified error band). Most models include an internal shunt calibration ("Rcal") function that is used to simulate a signal of 80% of full scale. This eliminates the need for a cumbersome calibrated pressure source when scaling associated instrumentation. Installation Do not remove protective cap until ready to install. Prior to initial installation, verify correct machining of mounting hole per Figure 1. Gauge Plug, P/N 200908, is available for this purpose. Before installing make sure that mounting hole is clear of material. Dynisco Cleaning Tool Kit, P/N 200100, should be used. To prevent galling, lightly coat transducer threads with a high temperature anti?seize material. An adequate seal, in a properly machined and maintained mounting well, is obtained with 100 in?lbs. mounting torque. The maximum torque recommended is 500 in?lbs. The electronics housing should be secured, with the optional mounting bracket (P/N 200941), in an area where the ambient temperature will not exceed 185°F (85°C). (Mounting bracket not supplied with EchoTM models.)Wiring Use shielded cable. Attach cable shield to ground at one end only. NOTE: DYNISCO cable assemblies are constructed with shield wired to transducer mating connector, so do not attach shield to instrument. Output Supply Voltage mV/V 10 Vdc (12 Vdc max) mA 14?36 Vdc Vdc 16?36 Vdc Start?Up Bring system to operating temperature with no pressure. For mA units, remove adjustment access screw and adjust Zero Output potentiometer. For mV/V units, zero adjustment must be handled by downstream indicator. Make sure that there is sufficient "soak time" to assure that any material at the tip of the transducer is molten before extruder drive is started. Removal Transducer should only be removed when polymer is hot and liquid. Wipe tip with a soft cloth immediately. The melt pressure transducer must be removed before using an abrasive material or wire brush to clean the extruder barrel. Clean the mounting well before attempting to reinstall the transducer with Dynisco Mounting Well Cleaning Tool Kit, P/N 200100. Thermocouple Thermocouples ( Type J or K) in a rigid stem are optionally available. The Type J (iron?constantan) and Type K is a T/C junction just behind the flush diaphragm at the tip of the transducer. For the most accurate temperature measurement of the melt stream, use a separate immersion?type thermocouple, such as Dynisco TB422 fixed depth series or (G)RMT adjustable models. The thermocouple assembly can be removed by loosening the set screw on the side of hex assembly and pulling the T/C probe, carefully, straight out, without twisting. Replacement assemblies are available. When installing the thermocouple probe assembly, align the slot with the pressure capillary tube and press into snout until top of probe shoulders flush against snout. Lock in place with set screw.Warranty This Dynisco product is warranted under terms and conditions set forth in the Dynisco Web Pages. Go to www.dynisco.com and click on “Warranty” at the bottom of any page for complete details.

Recommended Products For Dynisco


Dynisco PT482-1/2-5M-6/18-B379 Pressure Sensors
Dynisco TDA463-1/2-3,5C-20/46 Pressure Sensors
Dynisco 224200001317 Pressure Sensors
Dynisco PT4624-5M-6/18-SIL2 Pressure Sensors
Dynisco TPT463E-10M-6/18 Pressure Sensors
Dynisco MDT462F-1/2-5C-15/46 Melt Pressure Transmitters
Dynisco ATC8800230 Process Controller
Dynisco UPR900-2-1-1-1-0-0-0-0 Process Indicator
Dynisco MDT420CAN-/2-2C-15-HA51 Melt Pressure Transmitters
Dynisco ATC990202011010 Process Controller
Dynisco ECHO-MV3-BAR-R17-UNF-6PN-S06-F18-NTR Melt Pressure Transducers
Dynisco TDT432F-1/2-5C-46/46-S147-SIL2 Pressure Sensors
Dynisco IDA334-1M Pressure Transmitters
Dynisco PT160A-4M-H88 Pressure Sensors
Dynisco 462F0149 Pressure Sensor
Dynisco 1480-1-0-0-0 Panel Indicator
Dynisco PT4624-15M-6/18-GC7 Pressure Sensors
Dynisco ATC 880 Process Controller
Alfa Laval 9612628111 VALVE LKB-2 DN80 DIN M/W EPDM 316L KIT HANDLE 1.1 W/2 POS TYPE A
Weba DGN4T Electrohydraulic Actuator
REITZ GROUP MXE125-003130-00 Ventilator
Alfa Laval 9612628160 LKB-2 DIN W/W NW100-304L-EPDM W/HANDLE-2 POS.
Rotork IQ20/F14/A Actuator
Eaton Vickers (Danfoss) DG4V 3 0B M U NN6 60 Valve
Honeywell V15T16-EZ200A05 Limit Switch
Vulcanic 3114-23 Screw Plug Immersion Heater
Aoip MEDUSA R 999 High Temperature Primary Blackbody Source
Grundfos CR32-9 A-F-A-E-HQQE 3x400/690 50 HZ Pump
Alfa Laval 9612628617 LKB 76/3
Edur NHE1005G170L-2900 Pump
Jaquet DSD 2210.01 MTV Differential Hall Effect Speed Sensör
Winsmith 7LD Double Reduction Drop Bearing Speed Reducer
Vulcanic 2118-21 Screw Plug Immersion Heater
Alfa Laval 9615223119 VALVE UNIQUE RV-P 76.1 KV75 EPDM NC 200
Stenflex Type C-35 DN 250 Expansion Joint
Hydropa DS-307/SCH/V2/20-350/SL/C5 Pressure Switch
Edur CBFL50-160/G120-2900 Torque Flow Pump
Gat ESR 110 Slip Rings
Grundfos CR3-23 A- FGJ-AE-HQQE Auxılıary Boıler Feedwater Pump
Martens MLR430-2 Fill Level/Limit Level Switch
Officine Orobiche T25 NR Magnetic Level Alarm
Mahle Pi 3705-012 77810294 Duplex Filter