im-tek.com

Dynisco ECHO-MV3-BAR-R17-UNF-6PN-S06-F18-NTR Melt Pressure Transducers

Dynisco

Product Code: ECHO-MV3-BAR-R17-UNF-6PN-S06-F18-NTR Melt Pressure Transducers
Brand: Dynisco



GET OFFER: info@imtek.com.tr

Description for Dynisco ECHO-MV3-BAR-R17-UNF-6PN-S06-F18-NTR Melt Pressure Transducers

·         2 year warranty and 60 years of Dynisco industry experience·         Accuracy better than ±0.5%·         TiAlN diaphragm coating is standard·         mV/V, 0-10VDC, or mA outputs available·         Integral temperature sensor option·         Available in configurations that fit most extruder applications·         1.5M, 3M, 5M, 7.5M & 10M psi pressure range capability·         Alternative fill model available  Operating Principle The Dynisco EchoTM Melt Pressure Sensors are used to make pressure measurements of molten polymers up to 752°F (400°C). These models incorporate a 350?Ohm, bonded foil strain gage Wheatstone Bridge. This proven technology provides an output of 0?3.33 mV/V, & 4?20mA, 05?VDC and 0?10VDC proportional to melt pressure (within the specified error band). Most models include an internal shunt calibration ("Rcal") function that is used to simulate a signal of 80% of full scale. This eliminates the need for a cumbersome calibrated pressure source when scaling associated instrumentation. Installation Do not remove protective cap until ready to install. Prior to initial installation, verify correct machining of mounting hole per Figure 1. Gauge Plug, P/N 200908, is available for this purpose. Before installing make sure that mounting hole is clear of material. Dynisco Cleaning Tool Kit, P/N 200100, should be used. To prevent galling, lightly coat transducer threads with a high temperature anti?seize material. An adequate seal, in a properly machined and maintained mounting well, is obtained with 100 in?lbs. mounting torque. The maximum torque recommended is 500 in?lbs. The electronics housing should be secured, with the optional mounting bracket (P/N 200941), in an area where the ambient temperature will not exceed 185°F (85°C). (Mounting bracket not supplied with EchoTM models.)Wiring Use shielded cable. Attach cable shield to ground at one end only. NOTE: DYNISCO cable assemblies are constructed with shield wired to transducer mating connector, so do not attach shield to instrument. Output Supply Voltage mV/V 10 Vdc (12 Vdc max) mA 14?36 Vdc Vdc 16?36 Vdc Start?Up Bring system to operating temperature with no pressure. For mA units, remove adjustment access screw and adjust Zero Output potentiometer. For mV/V units, zero adjustment must be handled by downstream indicator. Make sure that there is sufficient "soak time" to assure that any material at the tip of the transducer is molten before extruder drive is started. Removal Transducer should only be removed when polymer is hot and liquid. Wipe tip with a soft cloth immediately. The melt pressure transducer must be removed before using an abrasive material or wire brush to clean the extruder barrel. Clean the mounting well before attempting to reinstall the transducer with Dynisco Mounting Well Cleaning Tool Kit, P/N 200100. Thermocouple Thermocouples ( Type J or K) in a rigid stem are optionally available. The Type J (iron?constantan) and Type K is a T/C junction just behind the flush diaphragm at the tip of the transducer. For the most accurate temperature measurement of the melt stream, use a separate immersion?type thermocouple, such as Dynisco TB422 fixed depth series or (G)RMT adjustable models. The thermocouple assembly can be removed by loosening the set screw on the side of hex assembly and pulling the T/C probe, carefully, straight out, without twisting. Replacement assemblies are available. When installing the thermocouple probe assembly, align the slot with the pressure capillary tube and press into snout until top of probe shoulders flush against snout. Lock in place with set screw.Warranty This Dynisco product is warranted under terms and conditions set forth in the Dynisco Web Pages. Go to www.dynisco.com and click on “Warranty” at the bottom of any page for complete details.

Recommended Products For Dynisco


Dynisco TDT463F-1/2-3,5C-15/46-A Pressure Sensors
Dynisco ATC8800230 Process Controller
Dynisco IDA-334-1 M-10V Pressure Transmitters
Dynisco 1490-4-0-0-0-0 Panel Indicator
Dynisco TPT463E-15M-6/18 Pressure Sensors
Dynisco VERT-MA4-MM1-NDC-BAR-R23-UNF-6PN-SO6-F18-NTR-NCC Melt Pressure Sensor
Dynisco UPR900-2-1-0-0-0-0-0-0 Process Indicator
Dynisco PT4624-15-M-6/18 Pressure Sensors
Dynisco ATC 880 Process Controller
Dynisco UPR900-20000000 Process Indicator
Dynisco TPT463E-35MPA-6/18 Pressure Sensors
Dynisco MDT 422 F-1/2-35-15/46 Melt Pressure Transmitters
Dynisco PT462E-M18-7CB-6/18 Pressure Sensors
Dynisco MDT 462F 1/2 3.5C 15/46 Melt Pressure Transmitters
Dynisco SPX2243-N-A25-B-21-CE-FF-C-CE-ZZ Pressure Sensors
Dynisco MDT462H-1/2-5C-15/46 Melt Pressure Transmitters
Dynisco TPT463E-5M-6/18 Pressure Sensors
Dynisco DYMT-S-1/2-PT100/4-10-32-G Melt Temperature Probe
Scherzinger 4050-450-DM-25-8 Titanium Gear Pumps 4050
Stauff G42NC-S-M10-B2.5 Limit Switch
Hansa-TMP F405G112 Flanges and Pipe Fitting
Gemü Gemü 1201S01Z205100 Mounting Kit
MAC 166B-611JM Valve
HFB GOS 234 BF Plummer Block Housings
Ritz GIF 20 Support Type Current Transformer
Watson-Marlow 0M3.5700.PFP Pumphead
FIP Italy DKLDC Series DN 15÷65 DIALOCK® 2-way Diaphragm Valve
Skf SNL522 22222 H322 FRB 13.5/200 TSN522S ASNH524 Plummer Block
Goldammer NR1/2
HFB SNI 522 Plummer Block Housing
Stahl 8264/5-SM-WS15kW400V-T DOL Motor Starters, Star Delta Starter, Soft Starter
Eltra EH63A1B500S24P8X ENCODER
SKF 21313 EK Spherical Roller Bearing
Aerzen 2000038629 Roller Bearing
Hengstler RI59-O/1000EQ.7AKB-K0 Encoder
Bollfilter 5370512 Bearing Bush
KWD BOKU-N-S1 40 – 400 x 30 – 60 H7P1(x80) – 50v – KWN 22014 Coupling
SKF D/W R166 R Deep Groove Ball Bearing
Duesterloh RM 250N Radial Piston Motor
Sensitron MULTISCAN 8+16 Control Unit
Elma 19 Solid and Perforated Front Panels
Brevini SH11C P 030 ME OB CBM FP2 DX V XXXX 000 Hydraulic Pump