im-tek.com

Dynisco ECHO-MV3-BAR-R21-UNF-6PN-S06-F18-NTR Melt Pressure Transducers

Dynisco

Product Code: ECHO-MV3-BAR-R21-UNF-6PN-S06-F18-NTR Melt Pressure Transducers
Brand: Dynisco



GET OFFER: info@imtek.com.tr

Description for Dynisco ECHO-MV3-BAR-R21-UNF-6PN-S06-F18-NTR Melt Pressure Transducers

·         2 year warranty and 60 years of Dynisco industry experience·         Accuracy better than ±0.5%·         TiAlN diaphragm coating is standard·         mV/V, 0-10VDC, or mA outputs available·         Integral temperature sensor option·         Available in configurations that fit most extruder applications·         1.5M, 3M, 5M, 7.5M & 10M psi pressure range capability·         Alternative fill model available  Operating Principle The Dynisco EchoTM Melt Pressure Sensors are used to make pressure measurements of molten polymers up to 752°F (400°C). These models incorporate a 350?Ohm, bonded foil strain gage Wheatstone Bridge. This proven technology provides an output of 0?3.33 mV/V, & 4?20mA, 05?VDC and 0?10VDC proportional to melt pressure (within the specified error band). Most models include an internal shunt calibration ("Rcal") function that is used to simulate a signal of 80% of full scale. This eliminates the need for a cumbersome calibrated pressure source when scaling associated instrumentation. Installation Do not remove protective cap until ready to install. Prior to initial installation, verify correct machining of mounting hole per Figure 1. Gauge Plug, P/N 200908, is available for this purpose. Before installing make sure that mounting hole is clear of material. Dynisco Cleaning Tool Kit, P/N 200100, should be used. To prevent galling, lightly coat transducer threads with a high temperature anti?seize material. An adequate seal, in a properly machined and maintained mounting well, is obtained with 100 in?lbs. mounting torque. The maximum torque recommended is 500 in?lbs. The electronics housing should be secured, with the optional mounting bracket (P/N 200941), in an area where the ambient temperature will not exceed 185°F (85°C). (Mounting bracket not supplied with EchoTM models.)Wiring Use shielded cable. Attach cable shield to ground at one end only. NOTE: DYNISCO cable assemblies are constructed with shield wired to transducer mating connector, so do not attach shield to instrument. Output Supply Voltage mV/V 10 Vdc (12 Vdc max) mA 14?36 Vdc Vdc 16?36 Vdc Start?Up Bring system to operating temperature with no pressure. For mA units, remove adjustment access screw and adjust Zero Output potentiometer. For mV/V units, zero adjustment must be handled by downstream indicator. Make sure that there is sufficient "soak time" to assure that any material at the tip of the transducer is molten before extruder drive is started. Removal Transducer should only be removed when polymer is hot and liquid. Wipe tip with a soft cloth immediately. The melt pressure transducer must be removed before using an abrasive material or wire brush to clean the extruder barrel. Clean the mounting well before attempting to reinstall the transducer with Dynisco Mounting Well Cleaning Tool Kit, P/N 200100. Thermocouple Thermocouples ( Type J or K) in a rigid stem are optionally available. The Type J (iron?constantan) and Type K is a T/C junction just behind the flush diaphragm at the tip of the transducer. For the most accurate temperature measurement of the melt stream, use a separate immersion?type thermocouple, such as Dynisco TB422 fixed depth series or (G)RMT adjustable models. The thermocouple assembly can be removed by loosening the set screw on the side of hex assembly and pulling the T/C probe, carefully, straight out, without twisting. Replacement assemblies are available. When installing the thermocouple probe assembly, align the slot with the pressure capillary tube and press into snout until top of probe shoulders flush against snout. Lock in place with set screw.Warranty This Dynisco product is warranted under terms and conditions set forth in the Dynisco Web Pages. Go to www.dynisco.com and click on “Warranty” at the bottom of any page for complete details.

Recommended Products For Dynisco


Dynisco UPR90021000000 Process Indicator
Dynisco 224000000000 Pressure Sensors
Dynisco PT 131B-M14-50MPA 150/370-K Pressure Sensors
Dynisco MDA462-1/2-3,5C-32/46 Pressure Sensors
Dynisco ECHO-MV3-BAR-R17-UNF-6PN-S06-F18-NTR Melt Pressure Transducers
Dynisco ATC990-4-0-0-1-1-0-0-0-0 Process Controller
Dynisco TPT4634-35MPA-12/18-SIL2 Pressure Sensors
Dynisco ECHO-MV3-BAR-R23-UNF-6PN-S06-F18-NTR Melt Pressure Transducers
Dynisco MDA460-1/2-7C-15 Pressure Sensors
Dynisco PT462E-3M-6/30 Pressure Sensors
Dynisco PT4624-15M-12/18-SIL2 Pressure Sensors
Dynisco MDT462F-1/2-7C-15/46 Melt Pressure Transmitters
Dynisco MDT 422F-M18-35-15/46-A Melt Pressure Transmitters
Dynisco PT462E-1/2-3M-6/18 Pressure Sensors
Dynisco MDT462H-1/2-7C-15/46-B106-D85 Melt Pressure Transmitters
Dynisco TPT432A-5M-6/18 Pressure Sensors
Dynisco PT291-6K4,8 B906 Pressure Sensors
Dynisco ATC990-4-0-1-1-0-1-000 Process Controller
Bartec 07-7311-9774-3100 Comb Relay Ex D E Iic Gb
Omal DC 10-24 (G1TU2L01)  (S182 A) 27x27 mm Lighted Valve Socket
Gemü 302150D3314BT41C1 Flow Transmitter, Turbine
FIP Italy VEEJV Series DN 65÷100 Easyfit 2-way Ball Valve
Micro Detectors BX80A/2P-1H Area Sensor
Vaisala DSS70A Portable Sampling System
Tokimec DG3V-7/DG3V-H8 Pilot Operated Directional Control Valves
Officine Orobiche CVM 50 Flow Alarm Switch
Honeywell 302-ET-194 Heat Detector
JUMO dTRANS p02 CERAMIC - Pressure Transmitter with Display (404387)
Valco TZ1 Flow Meter
Telestar Encoder SIL2/SIL3 Encoder
Ascon TH2PX500110H Thyristor
FSG PK 613 Precision Rotary Potentiometer
Kübler 8.0000.1102.0808 Coupling
Mecair PEX42H-110/50 Two-Way Normally Closed, Explosion Proof Pilot
Stenflex Type C-1 DN 800 Expansion Joint
Stenflex Type SF-20 DN 80 Expansion Joint
Kelvion NT Series Gasketed Plate Heat Exchanger
Gemü Gemü 88378589 Seal Kit Valve 514 80 Skv 532
Hirschmann RPS-80 EEC 943662-080 Power Supply
Aoip HYPERION Temperature Thermometers
Gemü Gemü 675 25D5855050 0 Diaphragm Valve
Fristam Us code 1710671000 Standard Housing