im-tek.com

Dynisco ECHO-MV3-BAR-R21-UNF-6PN-S06-F18-NTR Melt Pressure Transducers

Dynisco

Product Code: ECHO-MV3-BAR-R21-UNF-6PN-S06-F18-NTR Melt Pressure Transducers
Brand: Dynisco



GET OFFER: info@imtek.com.tr

Description for Dynisco ECHO-MV3-BAR-R21-UNF-6PN-S06-F18-NTR Melt Pressure Transducers

·         2 year warranty and 60 years of Dynisco industry experience·         Accuracy better than ±0.5%·         TiAlN diaphragm coating is standard·         mV/V, 0-10VDC, or mA outputs available·         Integral temperature sensor option·         Available in configurations that fit most extruder applications·         1.5M, 3M, 5M, 7.5M & 10M psi pressure range capability·         Alternative fill model available  Operating Principle The Dynisco EchoTM Melt Pressure Sensors are used to make pressure measurements of molten polymers up to 752°F (400°C). These models incorporate a 350?Ohm, bonded foil strain gage Wheatstone Bridge. This proven technology provides an output of 0?3.33 mV/V, & 4?20mA, 05?VDC and 0?10VDC proportional to melt pressure (within the specified error band). Most models include an internal shunt calibration ("Rcal") function that is used to simulate a signal of 80% of full scale. This eliminates the need for a cumbersome calibrated pressure source when scaling associated instrumentation. Installation Do not remove protective cap until ready to install. Prior to initial installation, verify correct machining of mounting hole per Figure 1. Gauge Plug, P/N 200908, is available for this purpose. Before installing make sure that mounting hole is clear of material. Dynisco Cleaning Tool Kit, P/N 200100, should be used. To prevent galling, lightly coat transducer threads with a high temperature anti?seize material. An adequate seal, in a properly machined and maintained mounting well, is obtained with 100 in?lbs. mounting torque. The maximum torque recommended is 500 in?lbs. The electronics housing should be secured, with the optional mounting bracket (P/N 200941), in an area where the ambient temperature will not exceed 185°F (85°C). (Mounting bracket not supplied with EchoTM models.)Wiring Use shielded cable. Attach cable shield to ground at one end only. NOTE: DYNISCO cable assemblies are constructed with shield wired to transducer mating connector, so do not attach shield to instrument. Output Supply Voltage mV/V 10 Vdc (12 Vdc max) mA 14?36 Vdc Vdc 16?36 Vdc Start?Up Bring system to operating temperature with no pressure. For mA units, remove adjustment access screw and adjust Zero Output potentiometer. For mV/V units, zero adjustment must be handled by downstream indicator. Make sure that there is sufficient "soak time" to assure that any material at the tip of the transducer is molten before extruder drive is started. Removal Transducer should only be removed when polymer is hot and liquid. Wipe tip with a soft cloth immediately. The melt pressure transducer must be removed before using an abrasive material or wire brush to clean the extruder barrel. Clean the mounting well before attempting to reinstall the transducer with Dynisco Mounting Well Cleaning Tool Kit, P/N 200100. Thermocouple Thermocouples ( Type J or K) in a rigid stem are optionally available. The Type J (iron?constantan) and Type K is a T/C junction just behind the flush diaphragm at the tip of the transducer. For the most accurate temperature measurement of the melt stream, use a separate immersion?type thermocouple, such as Dynisco TB422 fixed depth series or (G)RMT adjustable models. The thermocouple assembly can be removed by loosening the set screw on the side of hex assembly and pulling the T/C probe, carefully, straight out, without twisting. Replacement assemblies are available. When installing the thermocouple probe assembly, align the slot with the pressure capillary tube and press into snout until top of probe shoulders flush against snout. Lock in place with set screw.Warranty This Dynisco product is warranted under terms and conditions set forth in the Dynisco Web Pages. Go to www.dynisco.com and click on “Warranty” at the bottom of any page for complete details.

Recommended Products For Dynisco


Dynisco 2291NA48K11BUTTACAZZ Pressure Sensors
Dynisco ECHO-MV3-BAR-R21-UNF-6PN-S06-F18-NTR Melt Pressure Transducers
Dynisco PT412-5M 9/18-B784 Pressure Sensors
Dynisco TPT463E-1/2-5M-6/18 Pressure Sensors
Dynisco ECHOE22611122 Melt Pressure Sensors
Dynisco PT422A-10M-6/18 Pressure Sensors
Dynisco PT-462F-1/2-5M-6/18-A Pressure Sensors
Dynisco MDT422F-1 / 2-3.5C-15/99-SIL2 Melt Pressure Transmitters
Dynisco MDT422F-1/2-3,5C-15/46-SIL2 Melt Pressure Transmitters
Dynisco MDA460-1/2-1M-15 Pressure Sensors
Dynisco TDT463F-1/2-7C-15/46-SIL2 Pressure Sensors
Dynisco MDT 462F-1/2-3,5C-32/46A Melt Pressure Transmitters
Dynisco MDT462F-1-2-3,5C-15-46 Melt Pressure Transmitters
Dynisco MDT462F-1/2-2C-15/46-A Melt Pressure Transmitters
Dynisco VERT-MV3-MM1-NDC-PSI-R17-UNF-6PN-S06-NFL-NTR-NCC Melt Pressure Sensor
Dynisco PT460E-5CB-6 Pressure Sensors
Dynisco MDT 422 F-1/2-35-15/46 Melt Pressure Transmitters
Dynisco MDA460-1/2-5C-32 Pressure Sensors
Habasit NHZ-8ESBV-O1E3 Light Conveyor Belt
Adalet XCE/X-183608 Flameproof Control Enclosures
Cofi TRG823PC Ignition Transformer
American Industrial FBF-1660-TP Heat Exchanger
Moxa NPORT 5130A Convertor
T-T Electric AMP250 AC Motor
Leybold BAV 40 EP AL 24VDC AL, P/N: 215325 Valve
PSP Pohony EBM 16 brake with modular system
Conductix Wampfler 0815 1P2PH 25A TOW Current Collector
Fisher D Series (D138 and D139-D138 and D139) Filler Valves
Faulhaber 1336U018CXR DC-Micromotor
Moog Kit Connectors For Ds2020
Hengstler AC58/0012EK.42PBB-F0 Absolute Encoder
Asco 12600019 Solenoid Valve
Esam UNI JET 75 2V 019130 Blowers/Vacuum
Greisinger GTL130 Air/Gas Probe
ETP CLASSIC S-19 Hub-Shaft Connection
KOYO 7200CDT Angular contact ball bearings
Dropsa 0297010C Pump Element
Lamtec CMS Combustion Management System
Eaton Vickers (Danfoss) DGMX3-3-PPL-CW-B-40 Valve
Eaton Vickers (Danfoss) C2-815UA-S3 Hidrolik Check Valve Right Angle
Hengstler AC58/1212EF.47CLZ Absolute Encoder
SKF 6207 Bearing