im-tek.com

Dynisco ECHO-MA4-BAR-R23-UNF-6PN-S06-F18-TCJ Melt Pressure Sensors

Dynisco

Product Code: ECHO-MA4-BAR-R23-UNF-6PN-S06-F18-TCJ Melt Pressure Sensors
Brand: Dynisco



GET OFFER: info@imtek.com.tr

Description for Dynisco ECHO-MA4-BAR-R23-UNF-6PN-S06-F18-TCJ Melt Pressure Sensors

·         2 year warranty and 60 years of Dynisco industry experience·         Accuracy better than ±0.5%·         TiAlN diaphragm coating is standard·         mV/V, 0-10VDC, or mA outputs available·         Integral temperature sensor option·         Available in configurations that fit most extruder applications·         1.5M, 3M, 5M, 7.5M & 10M psi pressure range capability·         Alternative fill model available  Operating Principle The Dynisco EchoTM Melt Pressure Sensors are used to make pressure measurements of molten polymers up to 752°F (400°C). These models incorporate a 350?Ohm, bonded foil strain gage Wheatstone Bridge. This proven technology provides an output of 0?3.33 mV/V, & 4?20mA, 05?VDC and 0?10VDC proportional to melt pressure (within the specified error band). Most models include an internal shunt calibration ("Rcal") function that is used to simulate a signal of 80% of full scale. This eliminates the need for a cumbersome calibrated pressure source when scaling associated instrumentation. Installation Do not remove protective cap until ready to install. Prior to initial installation, verify correct machining of mounting hole per Figure 1. Gauge Plug, P/N 200908, is available for this purpose. Before installing make sure that mounting hole is clear of material. Dynisco Cleaning Tool Kit, P/N 200100, should be used. To prevent galling, lightly coat transducer threads with a high temperature anti?seize material. An adequate seal, in a properly machined and maintained mounting well, is obtained with 100 in?lbs. mounting torque. The maximum torque recommended is 500 in?lbs. The electronics housing should be secured, with the optional mounting bracket (P/N 200941), in an area where the ambient temperature will not exceed 185°F (85°C). (Mounting bracket not supplied with EchoTM models.)Wiring Use shielded cable. Attach cable shield to ground at one end only. NOTE: DYNISCO cable assemblies are constructed with shield wired to transducer mating connector, so do not attach shield to instrument. Output Supply Voltage mV/V 10 Vdc (12 Vdc max) mA 14?36 Vdc Vdc 16?36 Vdc Start?Up Bring system to operating temperature with no pressure. For mA units, remove adjustment access screw and adjust Zero Output potentiometer. For mV/V units, zero adjustment must be handled by downstream indicator. Make sure that there is sufficient "soak time" to assure that any material at the tip of the transducer is molten before extruder drive is started. Removal Transducer should only be removed when polymer is hot and liquid. Wipe tip with a soft cloth immediately. The melt pressure transducer must be removed before using an abrasive material or wire brush to clean the extruder barrel. Clean the mounting well before attempting to reinstall the transducer with Dynisco Mounting Well Cleaning Tool Kit, P/N 200100. Thermocouple Thermocouples ( Type J or K) in a rigid stem are optionally available. The Type J (iron?constantan) and Type K is a T/C junction just behind the flush diaphragm at the tip of the transducer. For the most accurate temperature measurement of the melt stream, use a separate immersion?type thermocouple, such as Dynisco TB422 fixed depth series or (G)RMT adjustable models. The thermocouple assembly can be removed by loosening the set screw on the side of hex assembly and pulling the T/C probe, carefully, straight out, without twisting. Replacement assemblies are available. When installing the thermocouple probe assembly, align the slot with the pressure capillary tube and press into snout until top of probe shoulders flush against snout. Lock in place with set screw.Warranty This Dynisco product is warranted under terms and conditions set forth in the Dynisco Web Pages. Go to www.dynisco.com and click on “Warranty” at the bottom of any page for complete details.

Recommended Products For Dynisco


Dynisco BP420-1/2-5M-6-CE Ropture disc
Dynisco IDA330-2C Pressure Transmitters
Dynisco ECHO-MV3-BAR-R21-UNF-6PN-S06-F18-NTR Melt Pressure Transducers
Dynisco TDT463F Pressure Sensors
Dynisco SPX2242NA00K22CEFFCACAAB300 Pressure Sensors
Dynisco MDT420F-1/2-5C-15-SIL2 Melt Pressure Transmitters
Dynisco PT4624-5M-6/18-SIL2 Pressure Sensors
Dynisco Model: PT291S-2CK-4,8/60-C6H-TC5 Pressure Sensors
Dynisco TDT463H-1/2-5C-15/46 Pressure Sensors
Dynisco TPT4634-5M-6/18-SIL2 Pressure Sensors
Dynisco DYMT-S-1/2-PT100/4-15-15-G Melt Temperature Probe
Dynisco PT462E-3M-6/18 Pressure Sensors
Dynisco MDT462F-M18-7C-15/46-A Melt Pressure Transmitters
Dynisco MDT422F-1/2-3,5C-15/46-SIL2 Melt Pressure Transmitters
Dynisco MDA460-1/2-5C-15 Pressure Sensors
Dynisco ATC990-411111000 Process Controller
Dynisco MDT420L-1/2-7C-15 Melt Presure Transmitters
Dynisco MDT462F-M18-3,5C-15/46-B171 Melt Pressure Transmitters
Emotron VFX69-375-IP Drive
Bartec 243061 Thin Fuse
Tellarini JIT 5 Electric Pump
Meister SPKM-32 Paddle Flow Monitor For Liquids
Stahl 8040/11-V30-033-S Control Box
Sitema KFH 80 KFH 080 71 Locking Unit
Grundfos MTR 2-3/3 A-W-A-HUUV Immersible Pump
Atlas Copco 2901110500 Kit Filter Air + Oil
Seim VMPI Series Valves
Nachi SA-G01-A3X-C1-31 Valve
Habasit HAM-5P Belt
Adler FT4 BALL VALVE WITH HEATING JACKET
Aignep 50040 STRAIGHT CONNECTOR
Grundfos NK 150-500/521 AA1F1AESBAQEYW3 Pump
Kaeser 1554 Particulate Filter Element (filter Element E22kd)
Alfa Laval 9615223210 VALVE UNIQUE RV-P DN100 KV110 EPDM NO
Meggitt Vibro-Meter VM600 MPC4 Machinery Protection Card
Faggiolati X209T6D2-J7LA4 Pump
Enerpac RSM200K50 Seal Kit
Parker 30P110QHBE2KS162 Duplex Filter
Dafram R9FP Ball Valve
Bürkert 6281 ID 00221898 Soelnoid Valve
Honeywell 302-ET-194 Heat Detector
Parker 30P205QBM2KS164 Duplex Filter