im-tek.com

Dynisco ECHO-VT1-MPA-R22-M14-6PN-S06-F18-TCK Melt Pressure Transducer

Dynisco

Product Code: ECHO-VT1-MPA-R22-M14-6PN-S06-F18-TCK Melt Pressure Transducer
Brand: Dynisco



GET OFFER: info@imtek.com.tr

Description for Dynisco ECHO-VT1-MPA-R22-M14-6PN-S06-F18-TCK Melt Pressure Transducer

·         2 year warranty and 60 years of Dynisco industry experience·         Accuracy better than ±0.5%·         TiAlN diaphragm coating is standard·         mV/V, 0-10VDC, or mA outputs available·         Integral temperature sensor option·         Available in configurations that fit most extruder applications·         1.5M, 3M, 5M, 7.5M & 10M psi pressure range capability·         Alternative fill model available  Operating Principle The Dynisco EchoTM Melt Pressure Sensors are used to make pressure measurements of molten polymers up to 752°F (400°C). These models incorporate a 350?Ohm, bonded foil strain gage Wheatstone Bridge. This proven technology provides an output of 0?3.33 mV/V, & 4?20mA, 05?VDC and 0?10VDC proportional to melt pressure (within the specified error band). Most models include an internal shunt calibration ("Rcal") function that is used to simulate a signal of 80% of full scale. This eliminates the need for a cumbersome calibrated pressure source when scaling associated instrumentation. Installation Do not remove protective cap until ready to install. Prior to initial installation, verify correct machining of mounting hole per Figure 1. Gauge Plug, P/N 200908, is available for this purpose. Before installing make sure that mounting hole is clear of material. Dynisco Cleaning Tool Kit, P/N 200100, should be used. To prevent galling, lightly coat transducer threads with a high temperature anti?seize material. An adequate seal, in a properly machined and maintained mounting well, is obtained with 100 in?lbs. mounting torque. The maximum torque recommended is 500 in?lbs. The electronics housing should be secured, with the optional mounting bracket (P/N 200941), in an area where the ambient temperature will not exceed 185°F (85°C). (Mounting bracket not supplied with EchoTM models.)Wiring Use shielded cable. Attach cable shield to ground at one end only. NOTE: DYNISCO cable assemblies are constructed with shield wired to transducer mating connector, so do not attach shield to instrument. Output Supply Voltage mV/V 10 Vdc (12 Vdc max) mA 14?36 Vdc Vdc 16?36 Vdc Start?Up Bring system to operating temperature with no pressure. For mA units, remove adjustment access screw and adjust Zero Output potentiometer. For mV/V units, zero adjustment must be handled by downstream indicator. Make sure that there is sufficient "soak time" to assure that any material at the tip of the transducer is molten before extruder drive is started. Removal Transducer should only be removed when polymer is hot and liquid. Wipe tip with a soft cloth immediately. The melt pressure transducer must be removed before using an abrasive material or wire brush to clean the extruder barrel. Clean the mounting well before attempting to reinstall the transducer with Dynisco Mounting Well Cleaning Tool Kit, P/N 200100. Thermocouple Thermocouples ( Type J or K) in a rigid stem are optionally available. The Type J (iron?constantan) and Type K is a T/C junction just behind the flush diaphragm at the tip of the transducer. For the most accurate temperature measurement of the melt stream, use a separate immersion?type thermocouple, such as Dynisco TB422 fixed depth series or (G)RMT adjustable models. The thermocouple assembly can be removed by loosening the set screw on the side of hex assembly and pulling the T/C probe, carefully, straight out, without twisting. Replacement assemblies are available. When installing the thermocouple probe assembly, align the slot with the pressure capillary tube and press into snout until top of probe shoulders flush against snout. Lock in place with set screw.Warranty This Dynisco product is warranted under terms and conditions set forth in the Dynisco Web Pages. Go to www.dynisco.com and click on “Warranty” at the bottom of any page for complete details.  

Recommended Products For Dynisco


Dynisco MDA462-1/2-3,5C-32/46 Pressure Sensors
Dynisco PT4624-15M-12/18-SIL2 Pressure Sensors
Dynisco PT462E-5M-6/18 Pressure Sensors
Dynisco PT462E-3M-6/30 Pressure Sensor
Dynisco PT462E-7CB-6/18 Pressure Sensors
Dynisco PT462E-15M-12/18 Pressure Sensors
Dynisco ECHO-MV3-MPA-R21-UNF-HIR-S06-F18-NTR Melt Pressure Transducers
Dynisco IDA354-3,5C-S61 Pressure Transmitters
Dynisco PT462E-1/2-3M-6/18 Pressure Sensors
Dynisco PT482-1/2-15M-6/18-B379 Pressure Sensors
Dynisco UPR900-2-1-0-1-0-0-0-0 Process Indicator
Dynisco ATC990-4-0-1-1-0-1-0-0-0 Process Controller
Dynisco PT4626-10M-6/18 Pressure Sensors
Dynisco TPT432A-5M-6/18 Pressure Sensors
Dynisco UPR900-2-1-0-0-0-0-0-0 Process Indicator
Dynisco PT462E-M18-5M-6/18 Pressure Sensors
Dynisco MDT462F-1/2-5C-15/46-SIL2 Melt Pressure Transmitters
Dynisco MDA462-1/2-7C-15/46 Pressure Sensors
KSB BPD262/05+UMAI 150E-4/22 2.5 SQMM DOL. Pump
Mollet DF11TK MOLOSroto level limit switch
FIP Italy RVOAM Series DN 15÷100 Sediment Strainer
Edur SP/SU 701G180L-2900 Self-Priming Centrifugal Pump
DR. LEYE Flow fitting DA21 pH/LF
Zeppelin ZWR 125 Diverter Valve
Atos HR-016 11 Check Valves
SKF W 6206-2Z 030-062-016 Bearing
Brevini SH11CM 090 ME OD SAO FM2 RV N Pump
Scherzinger 5030-130-B-DM-150-6-Exd Stainless Steel Gear Pumps 5030
American Industrial AB-1606-TP Heat Exchanger
Stahl 8570/12-407-S-XX-X-XX-XXX Plug
SKF UCFC 215 Round Flange Ball Bearing Unit
Atlas Copco 2901205500 Repair Kit
Grundfos NK 80-180/145 AA1F1S3ESBQQEGW3 Pump
Eaton DG4V32AMUH760 NG6 Directional Valve
Atlas Copco 8102372013 DD145+ (G1 1/2) Air Filter
Grundfos NK 80-200/222 AA1F2AESBAQEMW3 Pump
SKF 71914 ACE/P4AL Angular Contact Ball Bearing
Vulcanic 2206-07 Flange Immersion Heater
KSB UPAC 4-009/12 -CCRDV-BSN 4T-52 Pump
Joyce/Dayton SF063L025 Acme Screw and Nuts
Grundfos MTR 15-3/3 A-W-A-HUUV Immersible Pump
Faulhaber 2619S006SR 112:1 DC-Gearmotor