im-tek.com

Dynisco ECHO-MV3-MPA-R21-UNF-6PN-S06-F18-NTR Melt Pressure Transducers

Dynisco

Product Code: ECHO-MV3-MPA-R21-UNF-6PN-S06-F18-NTR Melt Presure Transducers
Artikelnummer: Art.Nr. 0462300636
Brand: Dynisco



GET OFFER: info@imtek.com.tr

Description for Dynisco ECHO-MV3-MPA-R21-UNF-6PN-S06-F18-NTR Melt Pressure Transducers

·         2 year warranty and 60 years of Dynisco industry experience·         Accuracy better than ±0.5%·         TiAlN diaphragm coating is standard·         mV/V, 0-10VDC, or mA outputs available·         Integral temperature sensor option·         Available in configurations that fit most extruder applications·         1.5M, 3M, 5M, 7.5M & 10M psi pressure range capability·         Alternative fill model available  Operating Principle The Dynisco EchoTM Melt Pressure Sensors are used to make pressure measurements of molten polymers up to 752°F (400°C). These models incorporate a 350?Ohm, bonded foil strain gage Wheatstone Bridge. This proven technology provides an output of 0?3.33 mV/V, & 4?20mA, 05?VDC and 0?10VDC proportional to melt pressure (within the specified error band). Most models include an internal shunt calibration ("Rcal") function that is used to simulate a signal of 80% of full scale. This eliminates the need for a cumbersome calibrated pressure source when scaling associated instrumentation. Installation Do not remove protective cap until ready to install. Prior to initial installation, verify correct machining of mounting hole per Figure 1. Gauge Plug, P/N 200908, is available for this purpose. Before installing make sure that mounting hole is clear of material. Dynisco Cleaning Tool Kit, P/N 200100, should be used. To prevent galling, lightly coat transducer threads with a high temperature anti?seize material. An adequate seal, in a properly machined and maintained mounting well, is obtained with 100 in?lbs. mounting torque. The maximum torque recommended is 500 in?lbs. The electronics housing should be secured, with the optional mounting bracket (P/N 200941), in an area where the ambient temperature will not exceed 185°F (85°C). (Mounting bracket not supplied with EchoTM models.)Wiring Use shielded cable. Attach cable shield to ground at one end only. NOTE: DYNISCO cable assemblies are constructed with shield wired to transducer mating connector, so do not attach shield to instrument. Output Supply Voltage mV/V 10 Vdc (12 Vdc max) mA 14?36 Vdc Vdc 16?36 Vdc Start?Up Bring system to operating temperature with no pressure. For mA units, remove adjustment access screw and adjust Zero Output potentiometer. For mV/V units, zero adjustment must be handled by downstream indicator. Make sure that there is sufficient "soak time" to assure that any material at the tip of the transducer is molten before extruder drive is started. Removal Transducer should only be removed when polymer is hot and liquid. Wipe tip with a soft cloth immediately. The melt pressure transducer must be removed before using an abrasive material or wire brush to clean the extruder barrel. Clean the mounting well before attempting to reinstall the transducer with Dynisco Mounting Well Cleaning Tool Kit, P/N 200100. Thermocouple Thermocouples ( Type J or K) in a rigid stem are optionally available. The Type J (iron?constantan) and Type K is a T/C junction just behind the flush diaphragm at the tip of the transducer. For the most accurate temperature measurement of the melt stream, use a separate immersion?type thermocouple, such as Dynisco TB422 fixed depth series or (G)RMT adjustable models. The thermocouple assembly can be removed by loosening the set screw on the side of hex assembly and pulling the T/C probe, carefully, straight out, without twisting. Replacement assemblies are available. When installing the thermocouple probe assembly, align the slot with the pressure capillary tube and press into snout until top of probe shoulders flush against snout. Lock in place with set screw.Warranty This Dynisco product is warranted under terms and conditions set forth in the Dynisco Web Pages. Go to www.dynisco.com and click on “Warranty” at the bottom of any page for complete details.

Recommended Products For Dynisco


Dynisco MDA460-1/2-1M-15 Pressure Sensors
Dynisco 2291NA48K13BUMMACAZZ Pressure Sensors
Dynisco PT-462F-1/2-5M-6/18-A Pressure Sensors
Dynisco MDA462-1/2-3,5C-15/46 Pressure Sensors
Dynisco 1490-4-0-0-0-0 Panel Indicator
Dynisco MDT422F-1/2-1C-15/46-A Melt Pressure Transmitters
Dynisco PT4624-10M-6/18-SIL2 Pressure Sensors
Dynisco PT482-1/2-5M-6/18-B379 Pressure Sensors
Dynisco PT462E-10M-6/18 Pressure Sensors
Dynisco 462010136 Pressure Sensor
Dynisco 462F0156 Pressure Sensor
Dynisco DYMT-S-1/2-J-10-15-G-0,7M-F13 Melt Temperature Probe
Dynisco PT4624-1/2-5M-6/18-SIL2 Pressure Sensors
Dynisco PT4624-5M-6/18-SIL2 Pressure Sensors
Dynisco PT462F-1/2-10M-6/18 Pressure Sensors
Dynisco BP420-1/2-5M-6-CE Ropture disc
Dynisco TDT432F-1/2-3,5C-46/46-S137-SIL2 Pressure Sensors
Dynisco 1390-2-3 Temperature Indicator
Saip LP – LAVP Screw Type Diaphragm Accumulator
KSB MultiEco Pro 65 E 1~230V 50Hz IE2 Pump
Rebs FM Multiple Direct Feed Pump
Gelbau 212.00 3002.1200 Housing type A
Aerzen 028-176206000 DN200 Air Filter Cartridge
Weber flow-captor 4215 s101 + 4615.30 s101 flowmeter
Euba B4 Electric-actuator 1.000 Dan Push/ Pull
Stahl 8150/2-0360-0360-1502311 Ex i Terminal Box
Bucher Hydraulics WUVPOC-1CO-35-10 Pressure Relief Valve
Conductix wampfler 032250-160X100 Cable Trolley
Dropsa 671190 Distributor
JVM JV 246 Unbalance Motor
Hengesbach BT 63/80/100/160 Bimetal-thermometer
Hengstler AC58/1212EF.42SGD Absolute Encoder
HFB SNI 528 Plummer Block Housing
Grundfos NK 50-225/208 AA1F1S3ESBQQEPW1 Pump
Kadant 995.122/0003 RX Rotary Union
Faulhaber 2214S024BXTH Brushless DC-Flat Motor
Mecair 1 1/2' single diaphragm Pulse Valve
Eaton Vickers (Danfoss) DG4V-3S-2N-M-U-H5-60 Valve
Stenflex AS-1 DN 100 PN 16 Rubber Expan Joint
Landefeld Pipeline sockets distributors, 5-way, PN 16
ETP HYDRO-GRIP COMPACT-12/HSK63F Sleeve
Wilkerson C28-06-FLG0 Combination Unit