im-tek.com

Dynisco ECHO-MV3-PSI-R21-UNF-6PN-S06-F18-NTR Melt Pressure Transducers

Dynisco

Product Code: ECHO-MV3-PSI-R21-UNF-6PN-S06-F18-NTR Melt Pressure Transducers
Brand: Dynisco



GET OFFER: info@imtek.com.tr

Description for Dynisco ECHO-MV3-PSI-R21-UNF-6PN-S06-F18-NTR Melt Pressure Transducers

·         2 year warranty and 60 years of Dynisco industry experience·         Accuracy better than ±0.5%·         TiAlN diaphragm coating is standard·         mV/V, 0-10VDC, or mA outputs available·         Integral temperature sensor option·         Available in configurations that fit most extruder applications·         1.5M, 3M, 5M, 7.5M & 10M psi pressure range capability·         Alternative fill model available  Operating Principle The Dynisco EchoTM Melt Pressure Sensors are used to make pressure measurements of molten polymers up to 752°F (400°C). These models incorporate a 350?Ohm, bonded foil strain gage Wheatstone Bridge. This proven technology provides an output of 0?3.33 mV/V, & 4?20mA, 05?VDC and 0?10VDC proportional to melt pressure (within the specified error band). Most models include an internal shunt calibration ("Rcal") function that is used to simulate a signal of 80% of full scale. This eliminates the need for a cumbersome calibrated pressure source when scaling associated instrumentation. Installation Do not remove protective cap until ready to install. Prior to initial installation, verify correct machining of mounting hole per Figure 1. Gauge Plug, P/N 200908, is available for this purpose. Before installing make sure that mounting hole is clear of material. Dynisco Cleaning Tool Kit, P/N 200100, should be used. To prevent galling, lightly coat transducer threads with a high temperature anti?seize material. An adequate seal, in a properly machined and maintained mounting well, is obtained with 100 in?lbs. mounting torque. The maximum torque recommended is 500 in?lbs. The electronics housing should be secured, with the optional mounting bracket (P/N 200941), in an area where the ambient temperature will not exceed 185°F (85°C). (Mounting bracket not supplied with EchoTM models.)Wiring Use shielded cable. Attach cable shield to ground at one end only. NOTE: DYNISCO cable assemblies are constructed with shield wired to transducer mating connector, so do not attach shield to instrument. Output Supply Voltage mV/V 10 Vdc (12 Vdc max) mA 14?36 Vdc Vdc 16?36 Vdc Start?Up Bring system to operating temperature with no pressure. For mA units, remove adjustment access screw and adjust Zero Output potentiometer. For mV/V units, zero adjustment must be handled by downstream indicator. Make sure that there is sufficient "soak time" to assure that any material at the tip of the transducer is molten before extruder drive is started. Removal Transducer should only be removed when polymer is hot and liquid. Wipe tip with a soft cloth immediately. The melt pressure transducer must be removed before using an abrasive material or wire brush to clean the extruder barrel. Clean the mounting well before attempting to reinstall the transducer with Dynisco Mounting Well Cleaning Tool Kit, P/N 200100. Thermocouple Thermocouples ( Type J or K) in a rigid stem are optionally available. The Type J (iron?constantan) and Type K is a T/C junction just behind the flush diaphragm at the tip of the transducer. For the most accurate temperature measurement of the melt stream, use a separate immersion?type thermocouple, such as Dynisco TB422 fixed depth series or (G)RMT adjustable models. The thermocouple assembly can be removed by loosening the set screw on the side of hex assembly and pulling the T/C probe, carefully, straight out, without twisting. Replacement assemblies are available. When installing the thermocouple probe assembly, align the slot with the pressure capillary tube and press into snout until top of probe shoulders flush against snout. Lock in place with set screw.Warranty This Dynisco product is warranted under terms and conditions set forth in the Dynisco Web Pages. Go to www.dynisco.com and click on “Warranty” at the bottom of any page for complete details.

Recommended Products For Dynisco


Dynisco PT462E-3.5CB-6/18 Pressure Sensors
Dynisco 462200000292 Pressure Sensor
Dynisco ECHO-MV3-PSI-R22-UNF-6PN-S06-F18-TCJ Melt Pressure Transducers
Dynisco PT-462F-1/2-5M-6/18-A Pressure Sensors
Dynisco PT291- S4-7K-4,8 /3.2R-B906. 6K Pressure Sensors
Dynisco 1392-1-3 Temperature Indicator
Dynisco MDT462F-1/2-2C-15/46-A Melt Pressure Transmitters
Dynisco ATC990-4-0-0-1-1-0-0-0-0 Process Controller
Dynisco TDT463F-1/2-7C-15/46-SIL2 Pressure Sensors
Dynisco PT462E-1/2-10M-6/18 Pressure Sensors
Dynisco MDT420CAN-/2-7C-15-HA51 Melt Pressure Transmitters
Dynisco 2291SA51B14BSMMAACZZB300 Pressure Sensors
Dynisco DYMT-S-1/2-2xPT100/4-15-15-G Melt Temperature Probe
Dynisco PT160A-4M-H88 Pressure Sensors
Dynisco PT4624-15M-6/18-SIL2 Pressure Sensors
Dynisco DYMT-S-1/2-RTD-15-15-G Melt Temperature Probe
Dynisco TPT4634-1/2-5M-6/18-SIL2 Pressure Sensors
Dynisco TPT463E-1/2-7,5M-6/18 Pressure Sensors
Ru-Steel RSP 0010 RSP 6 Bolt Range with Spacer and Adaptors
Stauff SPB-S-2-10-B12-A-D200 Plastic Filter Breather
Inoxihp PF 400 Series Horizontal Triplex Plunger Pumps
Sibre SHI 252 FC Safety Brake with Console
Vogel DIN 878 Dial Indicator
Holmatro HGC 100 S 25 Multi Purpose Cylinder
Habasit FMB-4EIWK+H15 Food Belt
Atlas Copco 2901186400 Check Valve Kit ( Z2008 )
Stahl 9170/21-12-21s Switching Repeater
Fisher 299H Series Pressure Reducing Regulators
Trimod-Besta HB8 141R 041 Level Switch
Vaisala DMP5 Dew Point and Temperature Probe
Skf TMST 3 Stethoscopes
Stahl 8146/5-V27-210-09512-21-1 Load Disconnect and Manual Transfer Switch
Bernard Controls BCI0073480 Actuator
Doofor 2965404 Middle Ring
WENGLOR SS2-00VA000R2 Safety Through-Beam Sensor
Jaquet DSD1810.01P1HW speed sensor
Scherzinger 3030-070-B-DM-18-4-Exe Stainless Steel Gear Pumps 3030
BUCHER MTDA08-025M Flow Divider
Tsurumi KTV series 3-phase / 50Hz Tunnel Construction
MAC 35A-ACA-DDAA-1BA Valve
Yuken A37-F-R-01-C-K-32 Pump
Vogel MKF1-12EC01000 924 Single Line Pump