im-tek.com

Biolab Miniflash Touch Flash Point Analyzer

Biolab

Product Code: Miniflash Touch
Brand: Biolab



GET OFFER: info@imtek.com.tr

Description for Biolab Miniflash Touch Flash Point Analyzer

MINIFLASH TOUCH is a uniquely designed flash point tester for the determination of flashpoints of liquids and solids, using the Grabner flash point detection method of measuring the instantaneous pressure increase inside the continuously closed chamber, triggered by an energy-controlled electric arc. Heating the test chamber from the top avoids condensation of high volatile compounds, significantly improving the test results. Its continuously closed cup design and small sample volume of only 1-2 mL offers maximum safety, avoids offensive fumes in the testing area and reduces sample waste. The fast thermoelectric cooling at the end of a test and the fast and easy handling of the instrument save expensive labor time. The full color touch-screen of the MINIFLASH TOUCH runs on Microsoft® Windows® software and features an intuitive menu navigation that requires no training for flashpoint testing. Along with its convenient touch screen design, the MINIFLASH TOUCH offers an extended temperature range from 0 to 400°C, hassle-free communication with USB, Ethernet, LIMS and PCs and nearly unlimited storage capacity for programs and results. MINIFLASH determines the flash point according to ASTM D6450 and according to the advanced ASTM D7094 standard. This procedure describes the “Standard Test Method for Flash Point by Modified Continuously Closed Cup (MCCCFP)”, which offers the highest repeatability and reproducibility and an excellent correlation to the D93 Pensky-Martens method: “There is no statistically significant bias observed between ASTM D7094 and ASTM D93 Procedure A” as concluded during the last Round Robin. Furthermore, test results are equivalent to other well known standards such as Abel and TAG, and thanks to its unique design MINIFLASH can be used for more difficult applications such as flash-point testing of contaminated samples like diesel fuel in lube oil or gasoline in diesel fuel and for biodiesel testing. The new MINIFLASH TOUCH analyzer also includes improved methods for simulation of EN ISO 3679 and EN ISO 3680. Due to true portability and rugged housing, the MINIFLASH TOUCH is also the perfect solution for mobile labs and military applications. Features Flashpoint according to ASTM D6450 (Flash-Point by Continuously Closed Cup) and ASTM D7094 (Flash-Point by Modified Continuously Closed Cup) FLASHPOINT COMMITTEE STATEMENT: “There is no statistically significant bias observed between ASTM D7094 and ASTM D93 Procedure A.”), equivalent EN ISO 2719, excellent correlation to ASTM D56, ISO13736, IP170 New methods for EN ISO 3679 and EN ISO 3680 simulation Dilution Flashpoint Testing Go / No Go Flashpoint Testing Fast Screening Methods Automatic ignition cleaning method Maximum safety through Grabner continuously closed cup method (Ignition Protection Technology™) 1-2 ml sample size * No Open Flame, no offensive vapors in the lab * Highest accuracy (see precision statement) Extended temperature range: 0 to 400°C with external cooling (MINIFLASH FLPH TOUCH) Fully remote operable * Big, color touch-screen for convenient, intuitive menu navigation Touch Screen Runs on Microsoft® Windows®: Full integration with network, LIMS and PC Hassle-free communication and data transfer via USB and Ethernet USB printer support Good Laboratory Practice: User Access Control Portable for Mobile and Field Use (car battery connector) Worldwide standard method for the flavors and fragrances industry Approved for the ASTM specifications of recycled fuel and biodiesel Short measuring time (depends on sample type) due to small sample volume of 1-2 ml Combustion Analysis™ Excellent thermoelectric heating and cooling regulation through Peltier Protection Technology™ Specifications MINIFLASH FLP TOUCH: 0 to 200 C (32 to 390 F) MINIFLASH FLPH TOUCH: 0 to 400 C (32 to 750 F) MINIFLASH FLA/FLAH: With 8 sample capability autosampler Power Requirements: 100/110/230 V AC, 50/60 Hz, 150 W

Recommended Products For Biolab


Biolab Parafuel Nir In-line Analyzer
Biolab HD Maxine XRF Elemental Analyzer
Biolab Filmdist SP 200 Shorth Path Evaporator
Biolab TC40 Copper Corrosion Of Aromatic Hydrocarbons
Biolab Spectroil Q100 Oil & Fuel Elemental Analysis Spectrometer
Biolab Filmdist SP 500 Shorth Path Evaporator
Biolab TC16 Copper Corrosion Analyzer
Biolab PETRA EDXRF Sulfur Analysis System
Biolab PETRODIST 200 Crude Oil Distillation System
Biolab MINIDIS ADXpert Automatic Mint-Distillation System
Biolab MiniLab 53 Oil Analysis System
Biolab Filmdist TF 650 Thin-Film Evaporation
Biolab PETRODIST 300 Crude Oil Distillation System
Biolab TLC 15 Hydrometer Method Density Meter
Biolab CoolCheck® 2 Coolant And Diesel Exhaust Fluids (DEF) Analysis System
Biolab TLC Series Manuel Cloud And Pour Point Analyzer
Biolab PETRODIST 100 Crude Oil Distillation System
Biolab PAT940 TAN/TBN Analyzer
Vulcanic 6104-22 Standard Industrial Radiator
Satron VL5 Pressure Transmitter
Enerpac IN24-120105 Optional Add On Reducer Insert
Scherzinger 5040-350-DM-400-2-Exe Hastelloy (R) Gear Pumps 5040
Friedrich FB 200-2-7.1 Vibrator Motor F-Type
Goyen K2500 (M1183) Diaphragm Kit
Kadant 995.710/ RX Rotary Union
Stahl 8146/5-V27-210-10512-21-1 Load Disconnect and Manual Transfer Switch
Vogel SKFDSA1-F01W-1M1A Switch
Armatury AS00 Gate Valve
SKF 24-0159-6025 Piston Detector
MAC 421A-D0A-DM-DDFJ-1KJ/M599 Valve
Eaton Vickers (Danfoss) Rv5 10 S 0 35 Valve
Vulcanic 3120-04 Screw Plug Immersion Heater
Westcode W0507YH450 Rectifier Diode
Eaton NZM1-XSR-R Compact Switch Accessory
Asco 400913-142 Replacement Coil
Stenflex Type SF-13 DN 900 Expansion Joint
Kiepe NTS 018 91.064 084.018 Pull Rope Emergency Stop Switch
Eaton Vickers (Danfoss) 848AN00016A DG5V-7-6C-VM-U-H7-50 Control Valve
Joyce/Dayton MA1527B8130 Multipurpose Actuator
Samson 1170-2026 Position Sensor
Elmot Schaefer ES HO3 80 G4 Motor
Dynisco PT492-809-1000P-A Pressure Sensors