im-tek.com

Gestra TRS5-40

Gestra

Product Code: TRS5-40
Brand: Gestra



GET OFFER: info@imtek.com.tr

Description for Gestra TRS5-40

DescriptionThe control unit TRS 5-40 together with the temperature sensors TRS 5-6x and the temperature transmitter TRV 5-40 constitutes a temperature monitoring system. Two temperature sensors TRG 5-6x detect the temperature values which are then converted by the temperature transmitter TRV 5-40 and made available for the CAN bus in the form of a data telegram. The CANopen protocol is used for the data transfer via CAN bus. The control unit TRS 5-40 can be used ? as MIN and MAX temperature monitor in combination with the temperature transmitter TRV 5-40 and with one temperature sensor TRG 5-6x each and ? as temperature controller in combination with the temperature transmitter TRV 5-40 and with one temperature sensor TRG 5-6x (MIN or MAX) The control unit TRS 5-40 is also available with two actual value outputs 4 - 20 mA. The equipment combinations can be used for controlling or monitoring temperatures in steam boilers and (pressurised) hot water installations to TRD and EN 12952 and EN 12953.Function The control unit TRS 5-40 evaluates the data telegram coming from the temperature transmitter TRV 5-40 at regular intervals. This data telegram contains: ? Actual value and ajdusted switchpoint for measuring channel 1, ? Actual value and ajdusted switchpoint for measuring channel 2, ? Temperature in the housing of the temperature transmitter. In addition, the following error messages are also included in the data telegram: ? Malfunction in the temperature sensor (sensor damaged, short circuit), ? Temperature in the housing of the temperature transmitter too high, ? Communication error. The output relays 1 – 4 are assigned to the measuring channels 1 and 2 as follows: ? Measuring channel 1: Output relay 1 ? Measuring channel 2: Output relays 2, 3 and 4. To activate or de-activate the measuring channels and to set the functions use the code switch or the operating & display unit URB 2. Use the operating & display unit URB 2 to set the MIN / MAX temperature switchpoints for the temperature control as well as to establish the actual value outputs. If there is an error message relay(s) 1 and/or 4 will be de-energized.

Recommended Products For Gestra


Gestra RK76 DN65 PN40 Check Valve
Gestra RK16A DN 50 Check Valve
Gestra SDR
Gestra PED NRG16-50 PN40 Ø3/4"BSP L=1000mm Water Level Limiter
Gestra UNA45HL DN50 PN40 AO13D Kondensstop
Gestra WB26
Gestra BK28-ASME
Gestra NRS1-54
Gestra BB2-WITH-ANTI-CORROSION-LINING
Gestra LRS 1-50 Conductivity Switch
Gestra UNA25-PS
Gestra NRG 16-51 PN40 Level Sensor
Gestra PED NRS1-50 1E 230/50Hz >10,0uS Level Controller
Gestra RK 41 PN 6/16/ DN15 Check Valve
Gestra Mk35/31 PN25 Condensate Drain
Gestra CB24S DN150 Check Valve
Gestra UNA-PN25
Gestra NRG 16 -50 PN40 Level Sensor
Kadant 995.719/0001 RX Rotary Union
Samson 4763 Electropneumatic Positioner
Watson-Marlow 913.AJ32.024 Pumpsil Tubing
Gestra 17-MK45/1-020 Valve
Moog G772K620A Servo Valve
Westcode N1366JK120 Phase Control Thyristors-Capsule
Nippon TOP-N340/FAM Trochoid® Pumps
Servomech MA 100 Mod B Screw Jack
Bollfilter 3090418 O-ring
KSB MCPK125-100-160 GG NP2 A Pump
Asco X8316D014 MBMO 15499 Solenoid Valve Repair Kit
Aron AD5E03CMS12 Solenoid Valve
Grundfos 96623612 CRN64-3-1 BH-F-A-E-HQQE Pump
Fisher EZ Sliding-Stem Control Valve
Atlas Copco FILT. EL. DD/DDP 850-8000+ F 1629054717 Filter Element
Bimba FT-090.125 Flat-II® Non-Rotating Cylinder
Flovex BEM 1504 Fixed Straight Tubesheet Heat Exchangers
Fristam FDS 3 Twin Screw Pump
Senseca HD2KO1-010GM008-876 Flow Monitor
Vogel VPG 4 03051 Sectional Metering Device
Kübler 8.0000.6901.0010.0031 Encoder
Heidenhain ID392945-02 Connector
Alfa Laval TE67A330001010 FT: 40 m³/h,pulse with display,Clamp 2",N/A
Habasit NAB-20EFWV-A2F1 Food Belt