Product Name: Megger INGVAR Primary Current Injection Test System
Brand: Megger
Product Code: INGVAR
Tags: Megger
INGVAR Primary Test
INGVAR Primary
Megger INGVAR Primary Injection System
INGVAR Primary System
Megger INGVAR Current
Megger Primary Test System
INGVAR Current Test System
Megger Test System
Current Injection System
Primary Current Injection System
INGVAR Primary Current
Megger Injection System
Primary Current Injection
Megger Primary Current
INGVAR Primary Current Injection Test System
Megger INGVAR Primary Current Injection Test
Current Injection Test
Megger INGVAR Injection
Megger Primary Injection Test System
Megger Primary Current Injection
Primary Current Injection Test System
Are you interested in the product Megger INGVAR Primary Current Injection Test System from manufacturer Megger with code INGVAR? Contact us now and get offer. Imtek Engineering, the fastest and most reliable industrial equipment supplier in the world, will offer you the best offer!
Get Offer With E-Mail: info@im-tek.com
Get a offer for Megger INGVAR Primary Current Injection Test System from our live support team now!
Most advanced primary current injection test system to simplify all types of switchgear and CT commissioning, ground grid, circuit breaker testing and more Up to 5000 A output current Two units, each of about 20 kg, makes it easier to carry Unique I/30 function allows the current to be pre-set using low current to prevent test sample heating, thus eliminating corruption of test result This powerful test system is designed for primary injection testing of protective relay equipment and circuit breakers. It is also used to test the turns ratio of current transformers and for other applications that require high variable currents. The system consists of a control unit and a current unit. The two parts are portable, and INGVAR can be quickly assembled and connected. The control unit has many advanced features – a powerful measurement section for example, that can display turns ratio as well as time, voltage and current. A second measurement channel can be used to test an additional current or voltage. Current transformer turns ratio, impedance, power, power factor (cos ?) and phase angle are calculated and shown in the display. Current and voltage can be presented as percentages of nominal value. The fast-acting hold function freezes short-duration readings on the digital display when the voltage or contact signal arrives at the stop input, the object under test interrupts the current or injection is stopped.