Need Help? Chat with us on WhatsApp - We're here to assist you!
FAST DELIVERY FROM GERMANY TO WORLDWIDE
esn-type-8538-monitoring-device_792628.jpg
esn-type-8538-monitoring-device_792628.jpg

Quantity :

Request an Offer

97% customer satisfaction based on last 45 days of sales

ESN Type 8538 Monitoring Device

Ask for Stock

Brand:
Product Code:
Type 8538

Order Processing & Delivery Information:
As we supply industrial equipment, product availability and delivery timelines may vary. Once your order is placed, our sales team will contact you within 24 business hours (excluding weekends and holidays) to confirm stock status and estimated delivery time.



🎯 Need a Quote for ESN Type 8538 Monitoring Device?

Get the best price and fastest delivery for ESN Type 8538 Monitoring Device from ESN. Imtek Engineering offers worldwide industrial equipment supply with expert support.


Details:

The potential monitoring device Type 8538 operates as a remote reporting device and monitors the electrical isolation of insulated rail joints, overvoltage protectors and similar devices depending on the voltage.





























































































































































Technical Data

Dimensions

W/H/D 100/70/115 mm

Housing

ABS / Polycarbonate

Mounting

2 bores according to template, Top

 

hat rail
according to DIN
EN 50022

Protective device

Casing: IP 40; Terminals IP: 10

Ambient temp.

-20° C to +
60° C

Connections

2 x 2.5 mm2 solid
according to

 

DIN
46288 or 2 x 1.5 mm2 with

 

sleeve

Supply terminal

18 (PE); terminal 19 (N); terminal

 

20
(L)

Supply voltage

AC 230 V +10/-15 % (48 - 62 Hz);

 

approx.
3 VA

 

DC
19.2 V - 80 V; terminal 19
(L-);

 

terminal
20 (L+); approx. 1.5 W

Measurement input

Terminal 12 (BE), terminal 14 (WE)

Input resistance

Approx. 1 M?.

Input voltage

Max. 900 V continuous

Relay output

Terminal 1, 2, 3 (1 u,
potential-.free)

Response time

Dependent on position of selector

 

switch Position 0 60 sec.,
Positions 1

 

to
9 = displayed number x 12 h

Contact ass.

AC 250 V / 4 A cos? > 0.7

 

DC
120 V / 1 A resistive load

Displays

By means of LED’s; see reverse

 

1 yellow LED for relay closed

 

(normal operating)

 

1 yellow LED for teaching in phase

 

1
red LED for faults

 

1
red LED for warning

Times

Teaching in phase < 30 sec.

Test voltage

4 kVe?.

Accessories

Protective casing (IP
65) for external

 

fitting

Ordering Information

Type

Order No.

85380 (AC Version)

220100

85381 (DC-Version)

220101

Monitoring Device