AEP TA2USB Digital Transducer


AEP TA2USB Digital Transducer Image

AEP TA2USB Digital Transducer


Nom du Produit: AEP TA2USB Digital Transducer
Marque: AEP
Code Produit: TA2USB Digital Transducer
Mots-clés: AEP TA2USB Digital Transducer TA2USB Transducer Digital TA2USB Digital Digital Transducer AEP Digital Transducer AEP TA2USB AEP TA2USB Digital AEP TA2USB Digital Transducer AEP Transducer Transducer TA2USB AEP Digital AEP TA2USB Transducer
Article: TA2USB
TA2USB Digital Transducer



Êtes-vous intéressé par le produit AEP TA2USB Digital Transducer du fabricant AEP avec le code TA2USB Digital Transducer? Contactez-nous maintenant et obtenez une offre. Imtek Engineering, le fournisseur d\'équipements industriels le plus rapide et le plus fiable au monde, vous offrira la meilleure offre!

Obtenez une offre par e-mail: info@im-tek.com
Obtenez une offre pour AEP TA2USB Digital Transducer de notre équipe de support en direct maintenant!

he transmitter makes simple and economical the transmission of data coming from up to 2 load cells, transducers or potentiometers to a PC.TA2USB has a maximum resolution of ±50.000 divisions and transmits the data directly on-line USB 2.0.It is a very simple but complete instrument as it is self powered directly from the USB line and is ideal as acquisition system connected to a PC.The transmitter is controlled by a microcontroller that processes the data sampled by two 24bit ADC converters (one for each channels) at a frequency from 5 to 4800Hz.The instrument continuously transmits the value in divisions according to a protocol highly optimized and easy to implement and allows to get in real-time all the internal acquisition data.Accuracy 0,010%Through the USB line is possible to make the configuration of the transmitter parameters including:Digital Filter, ZEROConversion SpeedOperating mode: Standard / Peak.Available versions are:Input for load cells and dynamometers (standard)Input for transducers with voltage output (±10V). (option)Input for transducers with current output (4-20mA) (option)Input for PT100 for temperature measuringFrequency input for the measure of torsiometer rotational speedIt is possible to have the instrument in a 4 channel version (option). In this case 2 channel are of strain gauge type while the other two can be selected as voltage, temperature or current input.In this version the acquisition time is reduced but the accuracy is the same.The connection to transducers is achieved through a standard SUB-D 9-pin female connector.Complete with SoftwareACCESSORIESUSB cable.DB9 connector to connect the sensors to the transmitter.