im-tek.com

Dynisco ECHO-MV3-BAR-R21-UNF-6PN-S06-F18-NTR Melt Pressure Transducers

Dynisco

Product Code: ECHO-MV3-BAR-R21-UNF-6PN-S06-F18-NTR Melt Pressure Transducers
Brand: Dynisco



GET OFFER: info@imtek.com.tr

Description for Dynisco ECHO-MV3-BAR-R21-UNF-6PN-S06-F18-NTR Melt Pressure Transducers

·         2 year warranty and 60 years of Dynisco industry experience·         Accuracy better than ±0.5%·         TiAlN diaphragm coating is standard·         mV/V, 0-10VDC, or mA outputs available·         Integral temperature sensor option·         Available in configurations that fit most extruder applications·         1.5M, 3M, 5M, 7.5M & 10M psi pressure range capability·         Alternative fill model available  Operating Principle The Dynisco EchoTM Melt Pressure Sensors are used to make pressure measurements of molten polymers up to 752°F (400°C). These models incorporate a 350?Ohm, bonded foil strain gage Wheatstone Bridge. This proven technology provides an output of 0?3.33 mV/V, & 4?20mA, 05?VDC and 0?10VDC proportional to melt pressure (within the specified error band). Most models include an internal shunt calibration ("Rcal") function that is used to simulate a signal of 80% of full scale. This eliminates the need for a cumbersome calibrated pressure source when scaling associated instrumentation. Installation Do not remove protective cap until ready to install. Prior to initial installation, verify correct machining of mounting hole per Figure 1. Gauge Plug, P/N 200908, is available for this purpose. Before installing make sure that mounting hole is clear of material. Dynisco Cleaning Tool Kit, P/N 200100, should be used. To prevent galling, lightly coat transducer threads with a high temperature anti?seize material. An adequate seal, in a properly machined and maintained mounting well, is obtained with 100 in?lbs. mounting torque. The maximum torque recommended is 500 in?lbs. The electronics housing should be secured, with the optional mounting bracket (P/N 200941), in an area where the ambient temperature will not exceed 185°F (85°C). (Mounting bracket not supplied with EchoTM models.)Wiring Use shielded cable. Attach cable shield to ground at one end only. NOTE: DYNISCO cable assemblies are constructed with shield wired to transducer mating connector, so do not attach shield to instrument. Output Supply Voltage mV/V 10 Vdc (12 Vdc max) mA 14?36 Vdc Vdc 16?36 Vdc Start?Up Bring system to operating temperature with no pressure. For mA units, remove adjustment access screw and adjust Zero Output potentiometer. For mV/V units, zero adjustment must be handled by downstream indicator. Make sure that there is sufficient "soak time" to assure that any material at the tip of the transducer is molten before extruder drive is started. Removal Transducer should only be removed when polymer is hot and liquid. Wipe tip with a soft cloth immediately. The melt pressure transducer must be removed before using an abrasive material or wire brush to clean the extruder barrel. Clean the mounting well before attempting to reinstall the transducer with Dynisco Mounting Well Cleaning Tool Kit, P/N 200100. Thermocouple Thermocouples ( Type J or K) in a rigid stem are optionally available. The Type J (iron?constantan) and Type K is a T/C junction just behind the flush diaphragm at the tip of the transducer. For the most accurate temperature measurement of the melt stream, use a separate immersion?type thermocouple, such as Dynisco TB422 fixed depth series or (G)RMT adjustable models. The thermocouple assembly can be removed by loosening the set screw on the side of hex assembly and pulling the T/C probe, carefully, straight out, without twisting. Replacement assemblies are available. When installing the thermocouple probe assembly, align the slot with the pressure capillary tube and press into snout until top of probe shoulders flush against snout. Lock in place with set screw.Warranty This Dynisco product is warranted under terms and conditions set forth in the Dynisco Web Pages. Go to www.dynisco.com and click on “Warranty” at the bottom of any page for complete details.

Recommended Products For Dynisco


Dynisco PT482-1/2-5M-6/18-B379 Pressure Sensors
Dynisco MDT462F-1/2-1C-15/46-SIL2 Melt Pressure Transmitters
Dynisco MDT422T-1/2-3,5C-15/46A Melt Pressure Transmitters
Dynisco TDT432F-1/2-3.5C-15/46-SIL2 Pressure Sensors
Dynisco UPR90030000000 Process Indicator
Dynisco UPR900-20000000 Process Indicator
Dynisco MDT462F-1/2-3,5C-15/4... Melt Pressure Transmitters
Dynisco TPT463L-1/2-10M-6/18 Pressure Sensors
Dynisco MDT420CAN-/2-7C-15-HA51 Melt Pressure Transmitters
Dynisco 4622NA00P24CEDDAAFZZGC7 Pressure Sensor
Dynisco TPT4634-3M-6/18-SIL2 Pressure Sensors
Dynisco MDT422F-1/2-3.5C-15/46-SIL2 Melt Pressure Transmitters
Dynisco SPX4222-S-A-00-B-13-EZ-DD-C-AA-ZZ-Z017 Pressure Sensors
Dynisco TPT4634-2CB-6/18-S137A Pressure Sensors
Dynisco PT4624-3M-6/18-B171-A Pressure Sensors
Dynisco PT4624-15M-12/18-SIL2 Pressure Sensors
Dynisco MDA460-1/2-7C-15 Pressure Sensors
Dynisco UPR90031100100 Process Indicator
Alfa Valvole A11NF DN100 Valve Repair Kit
Samson 0520-0499 Diaphragm For Valve 390
Grundfos ALPHA1 L 25-80 180 Circulator Pump
Fybroc 1 X 1.5 X 8 Series 1600 Self-Priming Fiberglass Pump
Vogel ZP1002-S1 Gear Pump
Exheat FWD FWD Flameproof Air Warmers
Fisher Y692VB Series Vacuum Breaker
Bimba MRS-310.011-D Original Line® Magnetic Reed Switch
Heidenhain ID392945-02 Connector
Faggiolati G216R4T2-L10AA6 Pump
Alfa Laval 9612628346 LKB-2 DN25 DIN W/W EPDM 304L KIT ACT LKLA Ø85 NC 6MM
Scherzinger 4030-280-DM-12-8-Exe Stainless Steel Gear Pumps 4030
Hengstler AC58/1220ES.41ECR Absolute Encoder
Schimpf EX-Antrieb ?40Nm Serie Servo Motor
Grundfos CRE 1-9 A-FGJ-A-E-HQQE Multi Stage Pump
Turbo TI025(N-V-T)P Global Immersion Header Tank Ø8”
Jungmichel FE01E Switching Amplifier
Coax FK 25 TÜV Tüv Cerdified Valve
Hengstler AC58/0012EF.42PBV Absolute Encoder
Nuovafima 1.08.1.A.L.AAFV.43M 1 12G MANOMETRE
American Industrial CS-20108-SP Heat Exchanger
Bürkert 20002928 Solenoid Valve
Samson 3725 Ex- Proof
Faulhaber 3890H036CR DC-Micromotor