im-tek.com

Dynisco ECHO-MV3-BAR-R17-UNF-6PN-S06-F18-NTR Melt Pressure Transducers

Dynisco

Product Code: ECHO-MV3-BAR-R17-UNF-6PN-S06-F18-NTR Melt Pressure Transducers
Brand: Dynisco



GET OFFER: info@imtek.com.tr

Description for Dynisco ECHO-MV3-BAR-R17-UNF-6PN-S06-F18-NTR Melt Pressure Transducers

·         2 year warranty and 60 years of Dynisco industry experience·         Accuracy better than ±0.5%·         TiAlN diaphragm coating is standard·         mV/V, 0-10VDC, or mA outputs available·         Integral temperature sensor option·         Available in configurations that fit most extruder applications·         1.5M, 3M, 5M, 7.5M & 10M psi pressure range capability·         Alternative fill model available  Operating Principle The Dynisco EchoTM Melt Pressure Sensors are used to make pressure measurements of molten polymers up to 752°F (400°C). These models incorporate a 350?Ohm, bonded foil strain gage Wheatstone Bridge. This proven technology provides an output of 0?3.33 mV/V, & 4?20mA, 05?VDC and 0?10VDC proportional to melt pressure (within the specified error band). Most models include an internal shunt calibration ("Rcal") function that is used to simulate a signal of 80% of full scale. This eliminates the need for a cumbersome calibrated pressure source when scaling associated instrumentation. Installation Do not remove protective cap until ready to install. Prior to initial installation, verify correct machining of mounting hole per Figure 1. Gauge Plug, P/N 200908, is available for this purpose. Before installing make sure that mounting hole is clear of material. Dynisco Cleaning Tool Kit, P/N 200100, should be used. To prevent galling, lightly coat transducer threads with a high temperature anti?seize material. An adequate seal, in a properly machined and maintained mounting well, is obtained with 100 in?lbs. mounting torque. The maximum torque recommended is 500 in?lbs. The electronics housing should be secured, with the optional mounting bracket (P/N 200941), in an area where the ambient temperature will not exceed 185°F (85°C). (Mounting bracket not supplied with EchoTM models.)Wiring Use shielded cable. Attach cable shield to ground at one end only. NOTE: DYNISCO cable assemblies are constructed with shield wired to transducer mating connector, so do not attach shield to instrument. Output Supply Voltage mV/V 10 Vdc (12 Vdc max) mA 14?36 Vdc Vdc 16?36 Vdc Start?Up Bring system to operating temperature with no pressure. For mA units, remove adjustment access screw and adjust Zero Output potentiometer. For mV/V units, zero adjustment must be handled by downstream indicator. Make sure that there is sufficient "soak time" to assure that any material at the tip of the transducer is molten before extruder drive is started. Removal Transducer should only be removed when polymer is hot and liquid. Wipe tip with a soft cloth immediately. The melt pressure transducer must be removed before using an abrasive material or wire brush to clean the extruder barrel. Clean the mounting well before attempting to reinstall the transducer with Dynisco Mounting Well Cleaning Tool Kit, P/N 200100. Thermocouple Thermocouples ( Type J or K) in a rigid stem are optionally available. The Type J (iron?constantan) and Type K is a T/C junction just behind the flush diaphragm at the tip of the transducer. For the most accurate temperature measurement of the melt stream, use a separate immersion?type thermocouple, such as Dynisco TB422 fixed depth series or (G)RMT adjustable models. The thermocouple assembly can be removed by loosening the set screw on the side of hex assembly and pulling the T/C probe, carefully, straight out, without twisting. Replacement assemblies are available. When installing the thermocouple probe assembly, align the slot with the pressure capillary tube and press into snout until top of probe shoulders flush against snout. Lock in place with set screw.Warranty This Dynisco product is warranted under terms and conditions set forth in the Dynisco Web Pages. Go to www.dynisco.com and click on “Warranty” at the bottom of any page for complete details.

Recommended Products For Dynisco


Dynisco IDA354-3.5C-10V-S78B Pressure Transmitters
Dynisco PT160-3M-H3 Pressure Sensors
Dynisco PT462E-1/2-3M-6/18 Pressure Sensors
Dynisco TDT432F-1/2-5C-46/46-S137-SIL2 Pressure Sensors
Dynisco DYMT-F-1/2-PT100/3-0-32-G Melt Temperature Probe
Dynisco PT462E-1/2-10M-6/18 Pressure Sensors
Dynisco 1490-4-0-0-0-0 Panel Indicator
Dynisco PT462E-1/2-1M-6/18 Pressure Sensors
Dynisco PT415D-5M-6-B314-B173 Pressure Sensors
Dynisco PT 4624-35MPA-6/18 Pressure Sensors
Dynisco ATC990-401111000 Process Controller
Dynisco MDT462F-M18-3,5C-15/46-B171 Melt Pressure Transmitters
Dynisco PT160-4M-H88 Pressure Sensors
Dynisco PT4624-15M-12/18-SIL2 Pressure Sensors
Dynisco 462F0156 Pressure Sensor
Dynisco MDA460-1/2-1M-15 Pressure Sensors
Dynisco MDT467F-1/2-2C-SIL2 Melt Pressure Transmitters
Dynisco TPT4634-1/2-5M-6/18-SIL2 Pressure Sensors
Coax MK / FK 15 TÜV HT Tüv Cerdified Valve
Atlas Copco 2901146551 Electronic Drain Kit
Metalwork 3283031UA FR 100 5 08 SAC WITHOUT END PLATES
Armatury AS33 Gate Valve
KSB BPD273/04A+UMAI 150-4/22 320 V-2.5 SQMM Pump
Stahl 8146/1S71 Ex e Terminal Box
Gemü Gemü 8258 15 D 1 12 2 1 24= 6005 Valve
Wilkerson R41-0C-000 Air Regulator
Atlas Copco 0508 1100 98 Roler
Atlas Copco 1092 0024 23 Hose Assembly
Wilkerson MXP-96-651
Kadant 9940058/0004 SX Rotary Joint
Stahl 6161/3-70-321-0-1 Visual Signalling Device
Marzocchi ALP1D2 Lubrication Pump
Alwitco B00 3/8 Muffler
Vogel MKU5-13AE02000 428 Single Line Pump
Rotork YT-2500LSI2121F Smart Positioner
Joyce/Dayton AN450R067B Acme Screw and Nuts
Enerpac RSM300 Cylinder
SKF BHS-8002 Roller
Eaton MTL5514 Converter
KSB Amarex KRT ~ E 150-315/4 6 Pump
Samson 3730-3 Hart Exproof
Atos DHA-0711/M-24DC Solenoid Valve