im-tek.com

Dynisco ECHOE22611122 Melt Pressure Sensors

Dynisco

Product Code: ECHOE22611122 Melt Pressure Sensors
Brand: Dynisco



GET OFFER: info@imtek.com.tr

Description for Dynisco ECHOE22611122 Melt Pressure Sensors

·         2 year warranty and 60 years of Dynisco industry experience·         Accuracy better than ±0.5%·         TiAlN diaphragm coating is standard·         mV/V, 0-10VDC, or mA outputs available·         Integral temperature sensor option·         Available in configurations that fit most extruder applications·         1.5M, 3M, 5M, 7.5M & 10M psi pressure range capability·         Alternative fill model available  Operating Principle The Dynisco EchoTM Melt Pressure Sensors are used to make pressure measurements of molten polymers up to 752°F (400°C). These models incorporate a 350?Ohm, bonded foil strain gage Wheatstone Bridge. This proven technology provides an output of 0?3.33 mV/V, & 4?20mA, 05?VDC and 0?10VDC proportional to melt pressure (within the specified error band). Most models include an internal shunt calibration ("Rcal") function that is used to simulate a signal of 80% of full scale. This eliminates the need for a cumbersome calibrated pressure source when scaling associated instrumentation. Installation Do not remove protective cap until ready to install. Prior to initial installation, verify correct machining of mounting hole per Figure 1. Gauge Plug, P/N 200908, is available for this purpose. Before installing make sure that mounting hole is clear of material. Dynisco Cleaning Tool Kit, P/N 200100, should be used. To prevent galling, lightly coat transducer threads with a high temperature anti?seize material. An adequate seal, in a properly machined and maintained mounting well, is obtained with 100 in?lbs. mounting torque. The maximum torque recommended is 500 in?lbs. The electronics housing should be secured, with the optional mounting bracket (P/N 200941), in an area where the ambient temperature will not exceed 185°F (85°C). (Mounting bracket not supplied with EchoTM models.)Wiring Use shielded cable. Attach cable shield to ground at one end only. NOTE: DYNISCO cable assemblies are constructed with shield wired to transducer mating connector, so do not attach shield to instrument. Output Supply Voltage mV/V 10 Vdc (12 Vdc max) mA 14?36 Vdc Vdc 16?36 Vdc Start?Up Bring system to operating temperature with no pressure. For mA units, remove adjustment access screw and adjust Zero Output potentiometer. For mV/V units, zero adjustment must be handled by downstream indicator. Make sure that there is sufficient "soak time" to assure that any material at the tip of the transducer is molten before extruder drive is started. Removal Transducer should only be removed when polymer is hot and liquid. Wipe tip with a soft cloth immediately. The melt pressure transducer must be removed before using an abrasive material or wire brush to clean the extruder barrel. Clean the mounting well before attempting to reinstall the transducer with Dynisco Mounting Well Cleaning Tool Kit, P/N 200100. Thermocouple Thermocouples ( Type J or K) in a rigid stem are optionally available. The Type J (iron?constantan) and Type K is a T/C junction just behind the flush diaphragm at the tip of the transducer. For the most accurate temperature measurement of the melt stream, use a separate immersion?type thermocouple, such as Dynisco TB422 fixed depth series or (G)RMT adjustable models. The thermocouple assembly can be removed by loosening the set screw on the side of hex assembly and pulling the T/C probe, carefully, straight out, without twisting. Replacement assemblies are available. When installing the thermocouple probe assembly, align the slot with the pressure capillary tube and press into snout until top of probe shoulders flush against snout. Lock in place with set screw.Warranty This Dynisco product is warranted under terms and conditions set forth in the Dynisco Web Pages. Go to www.dynisco.com and click on “Warranty” at the bottom of any page for complete details.  

Recommended Products For Dynisco


Dynisco ATC990411101000 Process Controller
Dynisco MDT462F-M18-3,5C-50/46-A Melt Pressure Transmitters
Dynisco 462F0149 Pressure Sensor
Dynisco MDA460-1/2-5C-15 Pressure Sensors
Dynisco IDA334-1M-10V-D06 Pressure Transmitters
Dynisco PT4624-15-M-6/18 Pressure Sensors
Dynisco PT4624-35MPA-6/18 Pressure Sensors
Dynisco PT462E-7CB-6/18 Pressure Sensors
Dynisco TPT4634-5M-6/18 Pressure Sensors
Dynisco MDT422F-1/2-3.5C-15/46-B171-B173-SIL2 Melt Pressure Transmitters
Dynisco TPT463E-5M-6/18 Pressure Sensors
Dynisco MDT420F-1/2-1M-15-SIL2 Melt Pressure Transmitters
Dynisco MDT 462F-1/2-3,5C-32/46A Melt Pressure Transmitters
Dynisco MDA460-1/2-5C-15 Pressure Sensors
Dynisco MDA462-1/2-5C-15/46-B171 Pressure Sensors
Dynisco SPX2242NA00K22CEFFCACAAB300 Pressure Sensors
Dynisco DYMT-S-M18-J-7-15-G-2M-F13 Melt Temperature Probe
Dynisco MDA462-1/2-5C-15/46 Pressure Sensors
Mp Filter STR0502SG2M90P01 Filter
Gefran LR3-4-PRC Block-line Reactor
Atos DHE-0711/NPT 24DC Valve
Douglas GE HC CF8M Ball Float Steam Traps
Edur FUB500H180-2900 Torque Flow Pump
Amg Pesch SAF-180°-30 Double-Piston Quarter Turn Actuator
Eaton DSF 2401 Duplex Filter
Ako Armaturen Vm025.03X.50.30La Pneumatic Sleeve Valve
American Industrial CS-2036-SP Heat Exchanger
WENGLOR OCP352H0180 High-Performance Distance Sensor
Metalwork 3202101U 100 IN-SERIES REG. 1/4 0-2
Honsberg UR 1 MO 32MI , UR1-032GM-17 Flow Control
Atlas Copco 2255275100 Valve
MBS MLD 168 10 28 1 1500 Mixflo Multitube Demontable Heat Exchanger
Bucher Hydraulics QX23-008R-O Q 18197 182 Hydraulic Pump
JVM MS 50-50 Electro Magnetic Vibrator
Eaton DILM250/22 (RA250) Contactor
Enerpac VM2 Valve
SKF Lincoln MGH-LPLI-KR0000 Lubrication Pump
PSP Pohony ELB 16 electromagnetic brake
Kadant 995.132/0005 RX Rotary Union
Goyen RCA3D1-336 Solenoid Valve
Alfa Laval 9611444600 VALVE LKB 51/2
Stahl G537/2 Safety Switch