im-tek.com

Gestra SRL6-50

Gestra

Product Code: SRL6-50
Brand: Gestra



GET OFFER: info@imtek.com.tr

Description for Gestra SRL6-50

Description If the level electrode (high or low level limiter) is installed in an isolatable level pot outside the boiler, make sure that the level pot is drained and the connecting lines are rinsed at regular intervals. For this purpose the connecting lines must be shut off and opened at regular intervals and by opening and closing the drain valve the lines and the level pot will be rinsed. The logic unit is designed to be used in conjunction with level switch NRS 1-50 (water level limiter) or level switch NRS 1-51 (high level alarm) to monitor the correct timing and sequence of valve operations. During the rinsing process the level switch jumpers the level electrode, thus preventing the safety or control circuit from opening. The level switch - controlled by the logic unit - also monitors the rinsing and bypass time. Function The logic unit monitors the following times and process se - quences: Interval time: This is the time interval at which, depending on the operating mode (24h / 72h boiler operation without constant supervision), the connecting lines have to be rinsed. During operation the standby time is started after the in - terval time has elapsed and the interval time is reset to its initial value (24h/72h). During the standby time the connecting lines must be rinsed. Synchronizing: When valve D or E closes the purging time starts and the interval time is reset to 24h/72h. The purging time can start any time. The purging time can also start after the stand-by time has elapsed. After the purging time has started the stand-by input of the level switch NRS 1-50, NRS 1-51 will also be activated. During the purging time all valves must be opened and closed in a fixed sequence. The logic unit polls the limit switches to obtain data on the valve positions and the level electrode for information on the water level (low level if electrode is exposed). If valves D and E are open after the rinsing process and valve F closed and the level electrode for low water (low level) is submerged again, the stand-by input of the level switch will be deactivated. The stand-by time of the level switch is limited to a maxi - mum of 5 minutes. If the stand-by input is not deactivated by the logic unit during this time, the level switch will open the safety or control circuit

Recommended Products For Gestra


Gestra NRG19-41.1
Gestra RK86 DN125 PN40 Check Valve
Gestra RK76 PN40 DN50 Valve
Gestra TRG5-57
Gestra GSF330
Gestra BB2ASME Dual-Plate Check Valve
Gestra Repair Kit For BK 28 Thermostatic Steam Trap
Gestra OR52-5
Gestra CB24S
Gestra SMK22
Gestra CPBA000560 NRGS 16-1 PN 40 Level Sensor
Gestra KS 90-1 Level Controller
Gestra LRG16-4
Gestra NRS1-50 220V 0,5 μS/cm Low Level Controller
Gestra NRG16-50 PN40 level electrode
Gestra IB16A-7
Gestra BK36-5
Gestra UNA 45HL DN50 PN 40 Ball Float Steam Trap
Armatury AK91 Ball Valve
Valco HD1F / HD2F Flow Switch
Brevini QC32Q14R005 Flow Regulator Valve
Mp Filter CA040M90N Filter
Hansa-TMP 3GP 530 Gear Pumps
Pizzato FR 1655 Position Switch With Adjustable Lever And Roller
Alwitco B18 0503018 Bantam Muffler
Micro Detectors BX80A/1P-1HDA Area Sensor
Meister DKME/A-1/80 Flow Monitor And Indicator For Oil
Revere 700035-04 Single-Point Load Cell
Dynisco ATC 770-0-3-3 Process Controller
Vulcanic 3115-06 Screw Plug Immersion Heater
VISHAY BLH PS-1010T Web Tension Transmitter
NSD VLS-256PW128B Absocoder
Skf GS100.8.8 Pump Element
SKF Lincoln 501-301-313 Injection Oiler
Edur SBU602D160L-2900 Self-Priming Centrifugal Pump
Scherzinger 5040-210-B-DM-150-2-Exe Hastelloy (R) Gear Pumps 5040
Gestra CW44K
HFB GOF 234 Plummer Block Housing
Nuovafima MS4 DN100
CMO Series F Knife Gate Valve
KSB BPD273/12+UMAG150-21/21 4.0 SQMM S.D. Pump
Mp Filter Sa 145-G1-L03-A Filter