im-tek.com

Gestra NRG17-50

Gestra

Product Code: NRG17-50
Brand: Gestra



GET OFFER: info@imtek.com.tr

Description for Gestra NRG17-50

Description The level electrodes NRG 1...-50 are used in conjunction with level switch NRS 1-50 as water level limiters for steam boiler plants and (pressurised) hot water installations. Water level limiters switch off the heating when the water level falls below the set minimum level (low water). Function When the water level falls below the low level, the level electrode is exposed and a low level alarm is triggered in the level switch NRS 1-50. This switchpoint “Low water level (LW)” is determined by the length of the electrode tip. The electrode operation is based on the conductive measuring principle using the electrical conductivity of the water for signalling water level. The self-monitoring function ensures that an alarm will also be triggered if the electrode insulation is contaminated or has developed a leak and/or if there is a malfunction in the electrical connection. The level electrode is installed inside steam boilers, vessels or inlet lines of hot-water systems. The protection tube provided on site ensures the function. One level electrode NRS 1...-50 can be installed together with one GESTRA level electrode, one level switch or transmitter for water level control and low level alarm in one single protection tube or level pot. If the level electrode is installed in a level pot outside the boiler, make sure that the connecting lines are rinsed regularly. In addition, the logic unit SRL is required to monitor the purging times and the purging sequence. If the connecting lines for steam ? 40 mm and water ? 100 mm the installation is considered as “inside”. In this case the purging process does not have to be monitored.

Recommended Products For Gestra


Gestra BK29-ASME
Gestra LRGT 16-1 PN40 COMPACT ELECTRODE
Gestra BK28DN15 PN100 Steam Trap
Gestra VD23-VD26
Gestra BK36A-5-BAYER
Gestra NRG111-50
Gestra RK76 VALVE
Gestra VKP41PLUSEX
Gestra RK16C
Gestra BAE47 Continuous Blowdown Valve Reaktomat
Gestra NRGT26-1S
Gestra BA46 Continuous Blowdown Valve Reaktomat
Gestra MK35-31
Gestra SMK22-82
Gestra BK212-ASME
Gestra LRR1-50
Gestra LRR 1-40 24V electronic board
Gestra MPA46
Emotron VFX52-031-54 Drive
Fristam FSP 355 Pump
Kadant 995.163/0001 RX Rotary Union
Eaton CAP 846 674V1 Ex-cable Gland
Stahl 9170/21-12-11k Switching Repeater
Vogel MKU1-11BX13000 924 Single Line Pump
Eaton 301721 Pressure Gauge
Knf N 86.16 Series Temperature-Resistant Gas Sampling Valves
Senseca UR1-015HM Flow Switch
MBS MLW 88 19 12 1 1500 Sanitary Mixflo Multitube
Vulcanic 2116-18 Screw Plug Immersion Heater
Eaton Vickers (Danfoss) RV11-12-S-0-30 Relief Valve
Wilkerson Frp-96-653 Filter Element
Mls Lanny Dome pressure regulator type K (3/2 WV or 2/2 WV)
Bollfilter 550003
Graessner PowerGear HS Configuration H High Performance Bevel Gearbox
Doofor DF550L Hydraulic Rock Drill
Lammers 1TZ9001-1DD4 Squirrel Cage Motor
American Industrial SRCS-3284 Heat Exchanger
Hansa-TMP SFI3008300 Flanges and Pipe Fitting
Wandfluh AS32061A-R230 Valve
Ru-Steel GRM 45 Rigids
Jaquet DSF 1210.00 SHV Ex-atex (5m) Hall Effect Single Channel Speed Sensor
Eaton 02-412150 Valve