Gestra products, including Gestra NRGS11-2 Compact System for Level Monitoring, are sourced through parallel import channels and delivered to our customers worldwide with speed and reliability. As an authorized trading partner, Imtek Engineering offers genuine Gestra parts at competitive prices. Even if Gestra NRGS11-2 Compact System for Level Monitoring is not listed on our website, you are welcome to request a price quote — our team will respond promptly with a tailored offer.
- continued -
NRGS 11-2, NRGS 16-2
- continued -
Supply voltage 230 V +/– 10%, 50/60 Hz 115 V +/– 10%, 50/60 Hz 24 V +/– 10%, 50/60 Hz (optional)
Power consumption 5 VA Fuse external 63 mA , slow-blow, at 230 V and 115 V,
external 150 mA slow-blow at 24 V.
internal thermal fuse Tmax = 102 °C Response sensitivity (electrical conductivity of water at 25 °C)
>0.5 ...< 1000 µS/cm or >10 ...< 10 000 µS/cm (switch-selectable) Electrode voltage
10 Vss Output 2 volt-free relay contacts, 8 A 250 V AC / 30 V DC cos f = 1
De-energizing delay: 3 sec. (MIN alarm) 1 volt-free relay contact, 8 A 250 V AC / 30 V DC cos ϕ = 1
(e. g. feedwater pump ON).
Provide inductive loads with RC combinations according to manufacturer’s specification to ensure
interference suppression.
Indicators and adjustors 2 red LEDs for signalling “Low water level”, 1 green LED for “Pump ON”.
1 four-pole code switch for selecting the response sensitivity.
1 push button for testing the MIN (low-level) alarm.
1 Push button “Reset” Cable entry Cable gland with integral cable clamp M 16 (PG 9), M 20 (PG 16)
Protection
IP 65 to DIN EN 60529 Weight Approx. 0.8 kg Ambient temperature when system is switched on: 0 ° ... 70 °C, during operation: -10 ... 70 °C
Transport temperature –20 ... +80 °C (<100 hours), defrosting time of the de-energized equipment before it can be put into
operation: 24 hours.
Storage temperature –20 ... +70 °C, defrosting time of the de-energized equipment before it can be put into operation:
24 hours.
Relative humidity max. 95 %, no moisture condensation