Industrial spare parts & engineering solutions since 2001.
Gestra NRS1-50 Level Switch
Technical Datasheets / Product Documentations
| Brand | ![]() |
| Category | Switch |
| Product Name | Gestra NRS1-50 Level Switch |
| Product Code | NRS1-50 |
Contact with us! 24 business hours (excluding weekends and holidays) to confirm stock status and estimated delivery time.
Product Description
Gestra products, including Gestra NRS1-50 Level Switch, are sourced through parallel import channels and delivered to our customers worldwide with speed and reliability. As an authorized trading partner, Imtek Engineering offers genuine Gestra parts at competitive prices. Even if Gestra NRS1-50 Level Switch is not listed on our website, you are welcome to request a price quote — our team will respond promptly with a tailored offer.
NRS 1-50
Dimensions
100
74
16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
Technical Data Supply voltage 24 VDC +/– 20 %, 0.3 A 100 – 240 VAC + 10/– 15 %, 47 – 63 Hz, 0.2 A (optional)
External fuse M 0.5 A (semi-delay) Power consumption 7 VA Sensitvity of response
(Electrical conductivity of water at 25 °C) > 0.5 ... < 1000 μS/cm or > 10 ... < 10000 μS/cm
Electrical connection of level electrode To connect the level electrodes please use:
n For level switch NRS 1-50 with response sensitivity 10 μS:
Screened multi-core control cable, min. conductor size 0.5 mm2, e.g. LiYCY 4 x 0.5 mm2, max. length 100 m.
n For level switch NRS 1-50 with response sensitivity 0.5 μS:
Double-screened multi-core low-capacitance data cable, min.
conductor size 0.5 mm2, Li2YCY PiMF 2 x 2 x 0.5 mm2, max. length 30 m.
Stand-by input 2 volt-free inputs, 24 V DC, for monitoring the purging and
bypass time. Max. bypass time: 5 minutes.
Wiring: control cable 2 x 0.5 mm2.
Safety circuit 2 volt-free make contacts, 6 A 250 V AC / 30 V DC cos ϕ = 1.
Delay of response: 3 seconds, 15 sec. for marine applications.
Provide inductive loads with RC combinations according to manufacturer‘s specification to ensure interference
suppression.
Signal output 2 volt-free outputs for instantaneous external signalling,
24 V DC, max. 100 mA (semiconductor output).
Wiring: control cable 2 x 0.5 mm2.
Indicators and adjustors 2 buttons for test and diagnosis, 4 red/green LEDs for
indicating the operating mode and alarm.
3 red LEDs for fault diagnosis, 2 two-pole code switches for setting the number of electrodes.
Housing Housing material: base: polycarbonte, black; front: poly carbonate, grey. Terminal strips separately detachable
Fixing of housing: Mounting clip on supporting rail
TH 35, EN 60715.
Order & Enquiry Specification
GESTRA Level switch NRS 1-50 as water level limiter acc. to TRD, EN 12952/EN 12953
For TWO electrodes Certified to IEC 61508 (SIL3) Supply voltage ..................
Sensitivity ..................... μS/cm
Directives and Standards For more information on the conformity of the equipment as
well as applied Directives and Standards please refer to our Declaration of Conformity and associated certificates and/
or approvals.
Supply in accordance with our general terms of business.
GESTRA AG Münchener Straße 77, 28215 Bremen, Germany Telefon +49 421 3503-0, Telefax +49 421 3503-393
E-mail [email protected], Web www.gestra.com 818912-09/10-2024cm (808818-11) · GESTRA AG · Bremen
Test
Test
0
12 1
2
3
4
5
6
7
8
9 10 11 12 13 14 15
Wiring diagram
8
9
N
LL N (+) (-) (-) (+)
0
-– + +
a
0
9
-– + +
M 0,5A 0.5A M
16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
Test
1
Test
2
3
4
5
*
NRG 1..-50
NRG 1..-11
6
7
+ –
b
+ -
8
9 10 11 12 13 14 15
*
+ –
b
+ -
CEP 3 2
3 2
1
1
c
CEP
NRG 1..-50
NRG 1..-11
c 3 4 1
2
Key 8 Supply voltage 9 Signal output 1 / 2 for external alarm 24 V DC, 100 mA (semiconductor
output) 0 Safety circuit, input and output, external fuse: 2 A (anti-surge) or 1 A (anti-surge),
72 hours a Wire link, on site, when used as water level limiter acc. to
EN 12952 / EN 12953 b Stand-by input 1 / 2, 24 V DC, for connecting the logic unit
SRL 6-50 c Level electrode NRG 1...-50,
NRG 1...-11, NRG 16-36
CEP Central earthing point in control cabinet
* NRS 1-50 with response sensitivity 0.5 μS: Connect the two internal screens
to terminal 5/13 and to the CEP.
c
NRG 16-36
Electrical safety Degree of contamination: 2, overvoltage category III to
EN 61010-01.
Protection Housing: IP 40 to EN 60529, Terminal strip: IP 20 to
EN 60529 Weight approx. 0.5 kg Ambient temperature when system is switched on: 0 ° ... 55 °C,
during operation: -10 ... 55 °C Transport temperature -20 ... +80 °C (< 100 hours), defrosting time of the de
energized equipment before it can be put into operation:
24 hours.
Storage temperature -20 ... +70 °C, defrosting time of the de-energized equipment before it can be put into operation: 24 hours.
Relative humidity max. 95 %, no moisture condensation Site altitude max. 2000 m
Interlock In the event of an alarm the level switch NRS 1-50 does not interlock automatically. If an interlocking function in the
installation is required, the follow-up circuit (safety circuit) must be equipped with an interlock. The circuitry must meet
the requirements of the EN 50156.
Power supply and stand-by input Use a safety power supply unit (SELV) to feed the level switch
NRS 1-50 with 24 V DC. Only devices with protection by electrical separation or with low voltage may be connected
to the stand-by inputs.
Order & Enquiry Specification
GESTRA Level switch NRS 1-50 as water level limiter acc. to TRD, EN 12952/EN 12953
Supply voltage ..................
Sensitivity ..................... μS/cm
Frequently Asked Questions
Frequently asked questions about Gestra NRS1-50 Level Switch by Gestra. Imtek Engineering is ready to assist you in sourcing Gestra NRS1-50 Level Switch from Gestra in United States.
Imtek Engineering sources genuine Gestra products through trusted supply channels and supplies them to customers in United States at competitive prices.