im-tek.com

Gestra SRL6-50

Gestra

Product Code: SRL6-50
Brand: Gestra



GET OFFER: info@imtek.com.tr

Description for Gestra SRL6-50

Description If the level electrode (high or low level limiter) is installed in an isolatable level pot outside the boiler, make sure that the level pot is drained and the connecting lines are rinsed at regular intervals. For this purpose the connecting lines must be shut off and opened at regular intervals and by opening and closing the drain valve the lines and the level pot will be rinsed. The logic unit is designed to be used in conjunction with level switch NRS 1-50 (water level limiter) or level switch NRS 1-51 (high level alarm) to monitor the correct timing and sequence of valve operations. During the rinsing process the level switch jumpers the level electrode, thus preventing the safety or control circuit from opening. The level switch - controlled by the logic unit - also monitors the rinsing and bypass time. Function The logic unit monitors the following times and process se - quences: Interval time: This is the time interval at which, depending on the operating mode (24h / 72h boiler operation without constant supervision), the connecting lines have to be rinsed. During operation the standby time is started after the in - terval time has elapsed and the interval time is reset to its initial value (24h/72h). During the standby time the connecting lines must be rinsed. Synchronizing: When valve D or E closes the purging time starts and the interval time is reset to 24h/72h. The purging time can start any time. The purging time can also start after the stand-by time has elapsed. After the purging time has started the stand-by input of the level switch NRS 1-50, NRS 1-51 will also be activated. During the purging time all valves must be opened and closed in a fixed sequence. The logic unit polls the limit switches to obtain data on the valve positions and the level electrode for information on the water level (low level if electrode is exposed). If valves D and E are open after the rinsing process and valve F closed and the level electrode for low water (low level) is submerged again, the stand-by input of the level switch will be deactivated. The stand-by time of the level switch is limited to a maxi - mum of 5 minutes. If the stand-by input is not deactivated by the logic unit during this time, the level switch will open the safety or control circuit

Recommended Products For Gestra


Gestra UNA46AMAX
Gestra NRGS11-2 Compact System for Level Monitoring
Gestra LRGS15-1
Gestra RK26A DN32 PN 10-40 1.4408/1.4571 CHECK VALVE
Gestra SRK22A
Gestra NRGS16-1S
Gestra PA47
Gestra NRG16-19
Gestra CHECK VALVE RK 41 DN25 PN16
Gestra BK212-F91
Gestra RK86 A DN200 PN40/CL300 Non-Return Valve
Gestra RK41 DN65 PN6-16 Non-return valve
Gestra DK47-H
Gestra BA29 Continuous Blowdown Valve
Gestra 510 Continuous Blowdown Ball Valve
Gestra LRGT 16-1 G1 PN40 PT1000 4-20MA
Gestra UNA14
Gestra ZK313DIN
Bucher Hydraulics 3007010590+ Electronic Card
Edur SUB600C160L-2900 Self-Priming Centrifugal Pump
Topworx 7LG-13567DBA - SPDT, End Sensing, CSA GP, Green LED, 3-Pin, 316 Stainless Steel, Model 7L BriteLite GO Switch
Anderson Greenwood Amal IRDBE Flame Arrester
Esam AC 300ND 013370 Compressor
Italvibras MVSI 075/2110-S02 602891 Electric Vibrator
Hengstler RI58-O/10000EK.42IC Encoder
Eaton SBV11100000 + MCSCJ024DG000010 Valve
SETTIMA SFO Screw Pumps
Steimel EVK008F-----VB01 Valve Cone
HFB ZLGO 140 A Plummer Block Housing
Stahl 8573/13-304 Wall Mounting Sockets, Compact, With Extra Low Voltage
Nuovafima MGS32 DN125
Olaer IHV 20-265/13 Accumulator
Grundfos 98383020 MTR15-16/16 A-W-A-HUUV 3x400/690 50Hz Pump
Elero Junior 1/S Linear Actuator
Mecair PTD308 Bulkhead Connector
Vulcanic 2322-83 Screw Plug Immersion Heater
Faggiolati G209T6D1-J7AA0 Pump
Nuovafima BSM/M2
Atos DLEH-3C-X 24DC Directional Control Valve
Mahle Pi 281350/13-058 Duplex Filter
Brinkmann FH403A19 Pressure Boosting Pump
American Industrial UCF-1048 Heat Exchanger