im-tek.com

Gestra SRL6-50

Gestra

Product Code: SRL6-50
Brand: Gestra



GET OFFER: info@imtek.com.tr

Description for Gestra SRL6-50

Description If the level electrode (high or low level limiter) is installed in an isolatable level pot outside the boiler, make sure that the level pot is drained and the connecting lines are rinsed at regular intervals. For this purpose the connecting lines must be shut off and opened at regular intervals and by opening and closing the drain valve the lines and the level pot will be rinsed. The logic unit is designed to be used in conjunction with level switch NRS 1-50 (water level limiter) or level switch NRS 1-51 (high level alarm) to monitor the correct timing and sequence of valve operations. During the rinsing process the level switch jumpers the level electrode, thus preventing the safety or control circuit from opening. The level switch - controlled by the logic unit - also monitors the rinsing and bypass time. Function The logic unit monitors the following times and process se - quences: Interval time: This is the time interval at which, depending on the operating mode (24h / 72h boiler operation without constant supervision), the connecting lines have to be rinsed. During operation the standby time is started after the in - terval time has elapsed and the interval time is reset to its initial value (24h/72h). During the standby time the connecting lines must be rinsed. Synchronizing: When valve D or E closes the purging time starts and the interval time is reset to 24h/72h. The purging time can start any time. The purging time can also start after the stand-by time has elapsed. After the purging time has started the stand-by input of the level switch NRS 1-50, NRS 1-51 will also be activated. During the purging time all valves must be opened and closed in a fixed sequence. The logic unit polls the limit switches to obtain data on the valve positions and the level electrode for information on the water level (low level if electrode is exposed). If valves D and E are open after the rinsing process and valve F closed and the level electrode for low water (low level) is submerged again, the stand-by input of the level switch will be deactivated. The stand-by time of the level switch is limited to a maxi - mum of 5 minutes. If the stand-by input is not deactivated by the logic unit during this time, the level switch will open the safety or control circuit

Recommended Products For Gestra


Gestra NRS2-50
Gestra LRGT 16-1 PN40 COMPACT ELECTRODE
Gestra KDL13
Gestra ZK313DIN
Gestra TRG5-65
Gestra MK35/12 Thermostatic Steam Traps
Gestra SRL6-40
Gestra SMK22
Gestra BK36A-5-BAYER
Gestra BK28DN15 PN100 Steam Trap
Gestra LRG17-40
Gestra BK15
Gestra MK25-2
Gestra UNA25-PS
Gestra NRGS 16-1 LEVEL PROBE 1000MM
Gestra NRG16-27
Gestra MK45A-2
Gestra TRG5-57
Samson Type: 3271 Connection Part For 120-750 Cm2
Gefran M31-6-H-B35D-1-5-D 2130X000X00 Melt Pressure Sensor Complete Assy
Amot 6BRCB17007-00-AA Thermostatic Valve
Vogel MKU2-14BX03000 428 Single Line Pump
HFB SSNI 512 Plummer Block Housing
Eaton NMO-150-P02S-60L / F5803249 Monofilamentfilter Bags For Surface Filtration
Megger EZ-Restore Overdrive Series Cable Fault Locator
Taprogge R300 Cleaning Ball
SKF 6318 C3 Bearing
KSB BPI322/05C+UMAHSOL 150-15/23 A Pump
Eurotherm Er-Plx65: Dc-Drive 155 Amp 4-Q Digital Driver Eurotherm Er-Plx65: Dc-Drive 155 Amp 4-Q Digital Driver
Honeywell DCM10 20-546 Pressure Switch
Control Techniques SP1404 Unidrive
Honsberg RRI-010GVV070E05TPK Flow Transmitter
Fybroc 3x4x10 Series 7500 Cantilever Sump Pump
Topworx 81-20527DBD - 1/4Inch End Sensing, DPDT, UL GP, 4-Pin, Stainless Steel, Model 81 Go Switch
Aron ADB3E02CW002 ADB3E Cetop 03 valve 4/3 DC Coil
Mts Sensor 201 606-2* level transmitters
Senseca 00.0001.0418.1 FO-17.20.GV.3.C21B.J Flow Switch
HFB GUF 234 Plummer Block Housing
Eaton KBFDG4V-3-2C20N-Z-PE7-H7-10 Valve
Hengstler RI59-O/100AQ.7ARA Encoder
Vogel MKU1-12AE01000 428 Single Line Pump
PCM 500I5 Progressive Cavity Pump