im-tek.com

Gestra SRL6-50

Gestra

Product Code: SRL6-50
Brand: Gestra



GET OFFER: info@imtek.com.tr

Description for Gestra SRL6-50

Description If the level electrode (high or low level limiter) is installed in an isolatable level pot outside the boiler, make sure that the level pot is drained and the connecting lines are rinsed at regular intervals. For this purpose the connecting lines must be shut off and opened at regular intervals and by opening and closing the drain valve the lines and the level pot will be rinsed. The logic unit is designed to be used in conjunction with level switch NRS 1-50 (water level limiter) or level switch NRS 1-51 (high level alarm) to monitor the correct timing and sequence of valve operations. During the rinsing process the level switch jumpers the level electrode, thus preventing the safety or control circuit from opening. The level switch - controlled by the logic unit - also monitors the rinsing and bypass time. Function The logic unit monitors the following times and process se - quences: Interval time: This is the time interval at which, depending on the operating mode (24h / 72h boiler operation without constant supervision), the connecting lines have to be rinsed. During operation the standby time is started after the in - terval time has elapsed and the interval time is reset to its initial value (24h/72h). During the standby time the connecting lines must be rinsed. Synchronizing: When valve D or E closes the purging time starts and the interval time is reset to 24h/72h. The purging time can start any time. The purging time can also start after the stand-by time has elapsed. After the purging time has started the stand-by input of the level switch NRS 1-50, NRS 1-51 will also be activated. During the purging time all valves must be opened and closed in a fixed sequence. The logic unit polls the limit switches to obtain data on the valve positions and the level electrode for information on the water level (low level if electrode is exposed). If valves D and E are open after the rinsing process and valve F closed and the level electrode for low water (low level) is submerged again, the stand-by input of the level switch will be deactivated. The stand-by time of the level switch is limited to a maxi - mum of 5 minutes. If the stand-by input is not deactivated by the logic unit during this time, the level switch will open the safety or control circuit

Recommended Products For Gestra


Gestra NRG 16-51 PN40 Level Sensor
Gestra SMK22
Gestra BK29 DN15 PN160 Steam Trap
Gestra TRG5-67
Gestra BB14C DN250 PN16 Check Valve
Gestra RK76 DN20 PN40 Check Valve
Gestra NRG19-50
Gestra RK76
Gestra BK45U
Gestra PED NRS1-50 2E 230/50Hz >10,0uS Level Controller
Gestra VKP41PLUSEX
Gestra GSF 14 DN250 PN16 FL Strainer
Gestra TRG5-64
Gestra NRG19-51
Gestra MK 45/2 PN 40 Thermal Condensate Drain
Gestra NRS1-40
Gestra Prs 8F 230 V Programmgiving
Gestra BK 28 DN25 PN100 Kondenstop
Trafag ATEX 947 Pressostat
Cemb T7-LVDT Valves Position Transducer
Faulhaber LM 2070-160-11 Linear DC-Servomotor
EKF CCL-CAPELLA Mezzanine I/O Expansion Board Quad Gigabit Ethernet Networking Controller
Dropsa 675101 Distributor
Gat ROTOCAP 160 Slip Rings
KSB BPD273/06+UMAI 150E-8/22 2.5 SQMM S D. Pump
Atlas Copco 1089914214 Hour Meter
Eaton Vickers (Danfoss) 25V21A-1C22R Pump
Doofor 705129 Front Cylinder
Vulcanic 2048-12 Screw Plug Immersion Heater
Olaer LOC2-007-4-D-B-0-00-T25-0-0-0 Air Oil Cooler
Alfa Valvole A20T15 NPTFDN15 Bleed Valve
Mecair DB18/G Diaphragm
Honsberg TF1-070M015HS Temperature Sensor
Skf 22212 EK Roller
Goyen K4503 Diaphragm Kit
KSB MultiEco 36 P 1~230V 50Hz IE2 Pump
Bürkert 00126452 Repair Kit
Westcode M1163NC450 Fast Recovery Diode
Eurotherm DC-Drive 270 Amp 4-Q Drives Eurotherm DC-Drive 270 Amp 4-Q Drives
Asco E909BB8LL1.3 Electronic Valve Controller
Servomech SJ 5 Mod B Screw Jack
Globe VA1PFG02_20 Vane Motor