im-tek.com

Gestra TRS5-40

Gestra

Product Code: TRS5-40
Brand: Gestra



GET OFFER: info@imtek.com.tr

Description for Gestra TRS5-40

DescriptionThe control unit TRS 5-40 together with the temperature sensors TRS 5-6x and the temperature transmitter TRV 5-40 constitutes a temperature monitoring system. Two temperature sensors TRG 5-6x detect the temperature values which are then converted by the temperature transmitter TRV 5-40 and made available for the CAN bus in the form of a data telegram. The CANopen protocol is used for the data transfer via CAN bus. The control unit TRS 5-40 can be used ? as MIN and MAX temperature monitor in combination with the temperature transmitter TRV 5-40 and with one temperature sensor TRG 5-6x each and ? as temperature controller in combination with the temperature transmitter TRV 5-40 and with one temperature sensor TRG 5-6x (MIN or MAX) The control unit TRS 5-40 is also available with two actual value outputs 4 - 20 mA. The equipment combinations can be used for controlling or monitoring temperatures in steam boilers and (pressurised) hot water installations to TRD and EN 12952 and EN 12953.Function The control unit TRS 5-40 evaluates the data telegram coming from the temperature transmitter TRV 5-40 at regular intervals. This data telegram contains: ? Actual value and ajdusted switchpoint for measuring channel 1, ? Actual value and ajdusted switchpoint for measuring channel 2, ? Temperature in the housing of the temperature transmitter. In addition, the following error messages are also included in the data telegram: ? Malfunction in the temperature sensor (sensor damaged, short circuit), ? Temperature in the housing of the temperature transmitter too high, ? Communication error. The output relays 1 – 4 are assigned to the measuring channels 1 and 2 as follows: ? Measuring channel 1: Output relay 1 ? Measuring channel 2: Output relays 2, 3 and 4. To activate or de-activate the measuring channels and to set the functions use the code switch or the operating & display unit URB 2. Use the operating & display unit URB 2 to set the MIN / MAX temperature switchpoints for the temperature control as well as to establish the actual value outputs. If there is an error message relay(s) 1 and/or 4 will be de-energized.

Recommended Products For Gestra


Gestra RK86 CHECK VALVE
Gestra PA47
Gestra NRS1-52
Gestra UNA25-PS
Gestra MK25-2
Gestra UNA-SPEZIAL-PN63
Gestra MK45-1
Gestra RK41 DN65 PN6-16 Non-return valve
Gestra VK16
Gestra NRG19-40
Gestra SRL6-40
Gestra LRGT 16-1 G1 PN40 PT1000 4-20 MA L:300MM
Gestra BK36A-5-BAYER
Gestra TRG5-68
Gestra BK37
Gestra RK29A
Gestra 3661800 MPA 46 DN50 Blowdown Valve
Gestra Flash Vessels Systems VD
Elma Type E33 Mechanical Incremental Encoder
Alwitco B00 3/8 Muffler
Holmatro HAHC20S10 Aluminium Hollow Plunger Cylinder
Eaton 384YOT4400-0714 Valve
Greisinger GTH175 PT-T Thermometer
Wandfluh RNXPM33-2 (664.8002) Valve
Sensitron S4167IL Sensor Head
Goyen VN-45-PC-50 Nozzle Assembly
FIP Italy RVDV-RVDT Series DN 10÷100 Sediment Strainer
Adalet XJF-101206 Explosion Proof Control Enclosures
Stahl 9412/00-320-11k Fieldbus Power Supply
Enerpac BSH7534 Socket
Aron ADB3E04CK003 ADB3E Cetop 03 valve 4/3 AC Coil
Kadant 995.553/0002 RX Rotary Union
Faggiolati X216R4D5-L10LA5 Pump
Grundfos NK 100-225/235 AA1F1S3ESBQQEMW3 Pump
MBS MLI 60 12 3000 Industrial Crossflo
Vibro Meter 204-453-000-011 Converter Iqs453
Coax HPB 08 Pressure Control Valve
Stahl 8146/5-V27-108-06510-21-1 Load Disconnect and Manual Transfer Switch
KWD ZAKU-N H 31500 – 350 – 300 H7 P1(x280)x 250 H7 P3(x280) – KWN 21017 Coupling
Nuovafima 3.29 Basınç Anahtarı
Atos DHQ-016/C/00-I Valve
Goldammer TR12-T2-A-FE-300-MS-III-M12-24V-0 Temperature-capillary tube-regulator