im-tek.com

Gestra TRS5-40

Gestra

Product Code: TRS5-40
Brand: Gestra



GET OFFER: info@imtek.com.tr

Description for Gestra TRS5-40

DescriptionThe control unit TRS 5-40 together with the temperature sensors TRS 5-6x and the temperature transmitter TRV 5-40 constitutes a temperature monitoring system. Two temperature sensors TRG 5-6x detect the temperature values which are then converted by the temperature transmitter TRV 5-40 and made available for the CAN bus in the form of a data telegram. The CANopen protocol is used for the data transfer via CAN bus. The control unit TRS 5-40 can be used ? as MIN and MAX temperature monitor in combination with the temperature transmitter TRV 5-40 and with one temperature sensor TRG 5-6x each and ? as temperature controller in combination with the temperature transmitter TRV 5-40 and with one temperature sensor TRG 5-6x (MIN or MAX) The control unit TRS 5-40 is also available with two actual value outputs 4 - 20 mA. The equipment combinations can be used for controlling or monitoring temperatures in steam boilers and (pressurised) hot water installations to TRD and EN 12952 and EN 12953.Function The control unit TRS 5-40 evaluates the data telegram coming from the temperature transmitter TRV 5-40 at regular intervals. This data telegram contains: ? Actual value and ajdusted switchpoint for measuring channel 1, ? Actual value and ajdusted switchpoint for measuring channel 2, ? Temperature in the housing of the temperature transmitter. In addition, the following error messages are also included in the data telegram: ? Malfunction in the temperature sensor (sensor damaged, short circuit), ? Temperature in the housing of the temperature transmitter too high, ? Communication error. The output relays 1 – 4 are assigned to the measuring channels 1 and 2 as follows: ? Measuring channel 1: Output relay 1 ? Measuring channel 2: Output relays 2, 3 and 4. To activate or de-activate the measuring channels and to set the functions use the code switch or the operating & display unit URB 2. Use the operating & display unit URB 2 to set the MIN / MAX temperature switchpoints for the temperature control as well as to establish the actual value outputs. If there is an error message relay(s) 1 and/or 4 will be de-energized.

Recommended Products For Gestra


Gestra NRS1-51
Gestra MB14 DN25 PN16 Non-Return Valves
Gestra AK45 Automatic drainage valve
Gestra KH Steam-Powered Condensate-Return Unit
Gestra RK86 A DN200 PN40/CL300 Non-Return Valve
Gestra NRS 1-53 24 VDC 4W SPECTOR MODUL
Gestra GK11
Gestra VKP10 Steam Trap Testing Equipment VAPOPHONE
Gestra GAV36F
Gestra CB26
Gestra UNA-SPEZIAL-PN63
Gestra SMK22-82
Gestra NRG26-21
Gestra UNA-SPEZIAL-TYP62
Gestra LRGT 16-2 G1 PN40 PT1000 4-20MA Conductivity Monitoring
Gestra NRG16-19
Gestra URB2
Gestra BB1ASME Dual-Plate Check Valve
Chaori QJH type tainless steel ball valve
Asco SCG551A017MS 48/dc Solenoid Valve
Gefran LT-H-0050-P L000X000B00 Potentiometer
ETP HYDRO-GRIP B-45/60-190 Sleeve
Gefran LT-M-0350-S 0000X000A00 Potentiometer
KSB ETN 080-065-315 GG CP1CGA6 B Pump
Negele NVS-146.w Point Level Sensor For Hazardous Media (WHG)
ETP HYDRO-GRIP B-60/70-75 Sleeve
Gemü Gemü G-514 40 SKV 512 Valve
Alfa Laval 9612650105 NON-RETURN VALVE LKC-2-ISO- CLAMP-25-EPDM-316L
Leybold P/N: SV100B 960505V3004 Sogevac Vacuum Pump
Gefran PC-M-0850 0000X000D00 Potentiometer
Gefran PC-M-0225 L000X000D00 Potentiometer
Lamtec 662R2124 Actuator 140 Nm
Stenflex Type SA-13 DN 1000 Expansion Joint
Adalet VC4X6-241608V Quarter Turn Latch Terminal Enclosure
PSP Pohony ELS 1,2 electromagnetic clutch
KSB UPF 100/12+UMAI 150 Pump
Air Dimensions R061- Metric R-Series Heated Head Dia-Vac® Pump
Pressure Tech TS-300 Analyser & Instrumentation Regulator
American Industrial AA-1624-FP Heat Exchanger
Alfa Laval 9613360432 UNIQUE SSV 25/1 INCH 022 RA W-W 0.8/BLASTED EPDM SHUT OFF NC
Sai GM2 500 1H D40 Hydraulic Motor
Honsberg VD-050GR330-800 Flow Switch