im-tek.com

Goldammer NR 85-MA-SR45-L200-O-0-MS-M12 Level Rules

Goldammer

Product Code: Goldammer NR 85-MA-SR45-L200-O-0-MS-M12 Level Rules
Brand: Goldammer



GET OFFER: info@imtek.com.tr

Description for Goldammer NR 85-MA-SR45-L200-O-0-MS-M12 Level Rules

The NR 85-MA level/temperature controllerfor tank installation is a non-contact electromagnetic switch used for the continuous remote transmission of liquid levels and temperatures.Level and temperature can be continuously monitored via cables of any length for automatic control and display.The level controller contains a resistance measuring chain and a Pt100 resistor.The level- and temperature-dependent signal is converted into a linear current change of 4-20 mA in the integrated transmitter.Optionally, fixed bistable level contacts can be installed.The level controller is maintenance-free with non-segregating media.The device must only be installed by qualified personnel.Max. viscosity 320 mm²/s

Recommended Products For Goldammer


Goldammer MA-GB-305A/1 NR 1/2″-3/4″-M20-M24-MA(O)(T)-Art.Nr. … Level-temperature regulator with resistance measuring chain and restance thermometer, output 4-20mA
Goldammer NTR 85-SR40-T2-A-FE-L370-01-L1/250/S-T70Ö-III-M12 Level - Temperature - Capillary tube – Regulator
Goldammer AM-GB-200a/4, NRA 85 - PU - MA - NA, Level controler for contaminated media 4-20mA / 3 PNP outputs
Goldammer TR-GB-501/1, TR 15 - K3 / K4 - DIN43651, Temperature- Capillary tube - Regulator
Goldammer TR15-K6-A-FM300-2-I Temperature-capillary tube-regulator
Goldammer G1 ‘’-T-L200-T1- MS -2M12-TF70Ö-4-20mA Indicator
Goldammer G1 ‘’-T-L200-T3-VA-1M12-TF70Ö-4-20mA Indicator
Goldammer M12/5 Cable Box
Goldammer WM1-L100-MS 24VDC Water Detector
Goldammer NRA-W D-40822 230V Level Regulator for Surface Mounting
Goldammer BL-GB-802a, NR - BL - MA - OU, Level-Temperature regulator
Goldammer NTR 70-SR40-K1-A-FE-L370-01-L1/250/S-T50Ö-I Level - Temperature - Capillary tube – Regulator
Goldammer NRA 25RS/03x2000-3/NRAC-W-M12-MWG-7.5-I-G1/4’’A-G1/4’’E Level Regulator for Surface Mounting
Goldammer TR12-K1-A-FE-300-Ⅲ Temperature-capillary tube-regulator
Goldammer NTR 85-SR40-T1-A-FE-L370-01-L1/250/S-T80Ö-III-M12 Level - Temperature - Capillary tube – Regulator
Goldammer AM-GB-205/7, Datasheet - Measured value encoder MWG - G, Level controller for surface mounting
Goldammer MA-GB-309/1 NR G1 1/2″ – MA Level-temperature regulator with resistance measuring chain and restance thermometer, output 4-20mA
Goldammer M20-T-L200-T3-VA-1M12-TF70Ö-4-20mA Indicator
Mollet PF-KFALP1 Pendulum Level İndicator
Enerpac AM41 Manifold
Bürkert 00418803 8025-BC89-PDFF-P2-A-F4-C-BDN/DC-A Sensor
Scherzinger 3040-110-B-DM-18-2-Exe Hastelloy (R) Gear Pumps 3040
Edur PBU321G10.2-2900 Multiphase Pump
Greisinger GPH114 Digital pH-Meter
Tokimec TGMCR11- 3-BH-60 Valve
Mp Filtri FRI100BAF1A10NP01 Filter
Vogel MKU5-12EC01000 429 Single Line Pump
Fybroc 1.5x3x8 Series 7530 Close Coupled Cantilever Sump Pump
Watson-Marlow 999.3096.K00 Kynar Y Connectors For Bore Tube
Eaton Vickers (Danfoss) CVCS 25-A.B29-W.10 CVI25D16 L40 Valve
Vulcanic 2188-57 Flange Immersion Heater
Trafag 8728 Gas Density Monitor
Revere 9363-500kg-C3 Load Cell
Saip APT5 Pulsation Dampener
Heidenhain ERN1385/2048 74914653 Encoder
Industrie technik SF1K Flow Switch
Keller PR-25Y Transmıtter
John Bean Technologies T8026 Truck Tyre Changer
Roemheld 1947200 Screw-in Support Element
Brevini REM.SRA.X01C00 24V Electronic Card
Alfa Laval 9613000156 UNIQUE BASIC ISO-51/51 22-90 EPDM BLASTED (NONE BAL.)(NONE CIP)
SKF 6203 2Z/C3 Bearing