Goyen ECS-ACDC12 Control System


Goyen ECS-ACDC12  Control System Image

Are you interested in the product Goyen ECS-ACDC12 Control System from manufacturer Goyen with code ECS-ACDC12? Contact us now and get offer. Imtek Engineering, the fastest and most reliable industrial equipment supplier in the world, will offer you the best offer!

Get Offer With E-Mail: info@im-tek.com
Get a offer for Goyen ECS-ACDC12 Control System from our live support team now!

ECS Control System AC-IN DC-OUT 12-0/PThe ECS Control System is an intelligent controller developed to provide flexible solutions for economical filter life by minimising the costs associated with maintaining and operating modern dust filtration systems. The integrated dP transducer allows the controller to determine exactly when filters require cleaning. This feature ensures the filters are cleaned only when necessary, dramatically extending filter life and lowering emissions, while significantly reducing compressed air use. The ECS base board has 12 solenoid outputs on board. The addition of expansion cards, matched to the AC or DC output of the controller, increases this number to 360 outputs. The ECS may be ordered as the control board only or in an enclosure (polycarbonate).Features & Specifications:DP SUPPORT 0 to 4.5 kPaINPUT VOLTAGE AC: 100/240 V @ 50/60 HzOUTPUT VOLTAGE AC: 100/240 V @ 50/60 Hz (same as input). DC: 24 VMAXIMUM INPUT POWER AC IN, AC OUT Model: 235 W. AC IN, DC OUT Model: 65 WDISCRETE SOLENOID OUTPUTS 12 outputs, expandable up to 360 via 12 output expansion cardsPROTECTION RATING Polycarbonate: IP65 & NEMA 1, 4, 4X, 12 & 13OPERATING TEMPERATURE ?40°C to 60°C (?40°F to 140°F)ON & OFF TIME ON: 30 ms to 1000 ms, OFF: 1 s to 1000 sINPUTS Voltage Free: Fan Stop, Low Header Alarm, Demand/ContinuousOUTPUTS Voltage Free: Coil is Firing, Coil Alarm, High dP. Analogue Output: 4–20 mA dP signalHigh-performance, cost-minimising controller.Expansion cards extend the control up to 360 solenoid outputs.Quick Pulse TechnologyEach AC output can have 10 pilot valves connected in parallel, enabling up to 3600 pilot valves to be supported. Each DC output can have 2 pilot valves connected in parallel between ?40°C to 60°C (?40°F to 140°F), enabling up to 720 pilot valves to be supported.The main PCB only can have 3 DC pilot valves connected in parallel between ?20°C to 60°C (?4°F to 140°F).Low temperature operation ?40°C (?40°F)Automatic pilot valve detectionVoltage-free coil error output and a visual indication on the display showing which pilot valve output has an error, enabling quick fault finding and debugging.Conforms to the requirements of UL, CE, FCC and RCM.