im-tek.com

Goyen ECS-ACDC12 Control System

Goyen

Product Code: ECS-ACDC12
Brand: Goyen



GET OFFER: info@imtek.com.tr

Description for Goyen ECS-ACDC12 Control System

ECS Control System AC-IN DC-OUT 12-0/PThe ECS Control System is an intelligent controller developed to provide flexible solutions for economical filter life by minimising the costs associated with maintaining and operating modern dust filtration systems. The integrated dP transducer allows the controller to determine exactly when filters require cleaning. This feature ensures the filters are cleaned only when necessary, dramatically extending filter life and lowering emissions, while significantly reducing compressed air use. The ECS base board has 12 solenoid outputs on board. The addition of expansion cards, matched to the AC or DC output of the controller, increases this number to 360 outputs. The ECS may be ordered as the control board only or in an enclosure (polycarbonate).Features & Specifications:DP SUPPORT 0 to 4.5 kPaINPUT VOLTAGE AC: 100/240 V @ 50/60 HzOUTPUT VOLTAGE AC: 100/240 V @ 50/60 Hz (same as input). DC: 24 VMAXIMUM INPUT POWER AC IN, AC OUT Model: 235 W. AC IN, DC OUT Model: 65 WDISCRETE SOLENOID OUTPUTS 12 outputs, expandable up to 360 via 12 output expansion cardsPROTECTION RATING Polycarbonate: IP65 & NEMA 1, 4, 4X, 12 & 13OPERATING TEMPERATURE ?40°C to 60°C (?40°F to 140°F)ON & OFF TIME ON: 30 ms to 1000 ms, OFF: 1 s to 1000 sINPUTS Voltage Free: Fan Stop, Low Header Alarm, Demand/ContinuousOUTPUTS Voltage Free: Coil is Firing, Coil Alarm, High dP. Analogue Output: 4–20 mA dP signalHigh-performance, cost-minimising controller.Expansion cards extend the control up to 360 solenoid outputs.Quick Pulse TechnologyEach AC output can have 10 pilot valves connected in parallel, enabling up to 3600 pilot valves to be supported. Each DC output can have 2 pilot valves connected in parallel between ?40°C to 60°C (?40°F to 140°F), enabling up to 720 pilot valves to be supported.The main PCB only can have 3 DC pilot valves connected in parallel between ?20°C to 60°C (?4°F to 140°F).Low temperature operation ?40°C (?40°F)Automatic pilot valve detectionVoltage-free coil error output and a visual indication on the display showing which pilot valve output has an error, enabling quick fault finding and debugging.Conforms to the requirements of UL, CE, FCC and RCM.

Recommended Products For Goyen


Goyen IK2000 Repair Kit
Goyen RCA45FS000 Diaphragm Valve
Goyen RCA 45 T020 220V Valve
Goyen VNA45C-50 Nozzle Assembly
Goyen CA50T020 2' Pulse Valve
Goyen GY10QLS2-2938 VALVE
Goyen CA45DD010 Integral Pilot Operation
Goyen M1183 Diaphragm Kit
Goyen 3-8V7110-336 Pilot Valve Enclosure
Goyen CA25-TSX/1921 Replacement Top Cover
Goyen RCA76MM Manifold Flat Mount Valve
Goyen CA45T020 Pulse Valve
Goyen M 1182-RCA40 Type 4000 Repaır Kit
Goyen GYG601207-103 Coil
Goyen CA40MM Repair Kit
Goyen K0380 (M1131B) Valve Repair Kit
Goyen K7601 Diaphragm Kit
Goyen CA40MMFPX/3403 P/N: K0380 Pilot Repair Kit
Westcode N2055MC280 Phase Control Thyristors-Capsule
Atlas Copco 1613 2359 00 Piston
Westcar Rotogrid Alignment Couplings
Meister RVO/U-L20500 Flow Monitor And Indicator For Gases
Alfa Laval 9612628213 LKB-F ISO WELDING ENDS 63,5 EPDM 316L HANDLE - 2 P
Servomech BSA 40 Mechanical Linear Actuator
VIMARC DFP 500-6 Vibrator motors
Honeywell SPSTAXC1 CO 0-200 PPM Gas Sensor
Stahl 9004/ 01- 168- 050- 001 Safety Barriers With Electronic Current Limitation
Celem CSP 150 Conduction Cooled Capacitor
Gemü 554 40D 1 37 5 1 4 Valve
Revere 5123-1,0t-C3-20P1 Load Cell
Westcar 3574 1/2 GAS 180°C Fuse Cap
Adler FC2 DN25 FLAT BODY BALL VALVES
KSB ETN 050-032-1601GBSAA04GA2 B Pump
Böhmer FSK R 016.100 Ball Valve
Rickmeier R45/100 FL-Z-W-SA-E2-R Pump
Eaton DILM15-01-EA Power Contactor
Mp Filter HP3203A03AHP01 Filter
Joyce/Dayton CD3225 Machine Screw ComDRIVE
KSB BPI 322/05D+UMAIF 150-13/22 2.5 SQMM SD. Pump
Hengstler AX70/0010EK.72DPA-F0 Absolute Encoder
Conductix Wampfler TF1KP-TF2KP-TF3KP Spring Cable Reels
Grundfos NK150-250/226-214 EUPA1F1AESBQQE Pump