im-tek.com

HEIDENHAIN LC 115 Functional Safety Sealed Linear Encoder

HEIDENHAIN

Product Code: LC 115 Functional Safety
Brand: HEIDENHAIN



GET OFFER: info@imtek.com.tr

Description for HEIDENHAIN LC 115 Functional Safety Sealed Linear Encoder

SpecificationsLC 115LC 115LC 185Measuring standardCoefficient of linear expansionDIADUR glass scale with absolute track and incremental track, grating period 20 µm?therm  8 x 10–6 K–1Accuracy grade*±3 µm up to 3040 mm measuring length; ±5 µmMeasuring length ML* in mm 140 240 340 440 540 640 740 840 940 1040 1140 1240 1340 14401540 1640 1740 1840 2040 2240 2440 2640 2840 3040 3240 3440 3640 38404040 4240Functional safetyfor applications up to• SIL-2 according to EN 61 508• Category 3, PL 'd” according to EN ISO 13 849-1:2008–PFH15 x 10–9;ML > 3040 mm: 25 x 10–9 (up to 6000 m above sea level)–Safe position1)Encoder: ±550 ?m;ML > 3040 mm: ±2050 µm(safety-related meas. step SM = 220 ?m)–Mechanical connection: fault exclusions for loosening of the housing and scanning unit (page 21)InterfaceEnDat 2.2Ordering designationEnDat22EnDat02Measuring step At ±3 µmAt ±5 µm0.001 µm0.010 µm0.005 µm0.010 µmClock freq. (calc. time tcal)? 16 MHz (? 5 µs)? 2 MHz (? 5 µs)Incremental signals–? 1 VPP (20 µm)Cutoff frequency –3 dB–? 150 kHzElectrical connectionSeparate adapter cable (1 m/3 m/6 m/9 m) connectable on both sides to mounting blockCable length? 100 m2)? 150 m2)Voltage supplyDC 3.6 V to 14 VPower consumption (max.)3.6 V: ? 1.1 W; 14 V: ? 1.3 WTraversing speed? 180 m/min (max. acceleration in measuring direction ? 100 m/s2)Required moving force? 4 NVibration 55 Hz to 2000 Hzeffecting theShock 11 msHousing: ? 200 m/s2 (EN 60 068-2-6)Scanning unit: ? 200 m/s2 (EN 60 068-2-6)? 300 m/s2 (EN 60 068-2-27)Operating temperature0 °C to 50 °CProtection EN 60 5293)IP53 when installed according to instructions in the brochure, IP64 with sealing air from DA 400Mass0.55 kg + 2.9 kg/m measuring length* Please select when ordering1) Further tolerances may occur in subsequent electronics after position value comparison (contact manufacturer of subsequent electronics)2) With HEIDENHAIN cable; clock frequency ? 8 MHz3) In the application the LC must be protected from the intrusion of particles and liquids

Recommended Products For HEIDENHAIN


Heidenhain LC 495F 1240 5,0 Fanuc05 .. 12,50 12A 0MS14-LY .. .. 01 .. AE 1 37 ID 760 932-21 Linear Cetvel
HEIDENHAIN ECN 1123 Rotary Encoder With Integral Bearing
HEIDENHAIN LS 477 Sealed Linear Encoder
Heidenhain 589612-97 Encoder
Heidenhain LS 603 220 10,0 ML/2 .. W 55S08 .. 0,00 ~11μAss 04 01 .. ID.336972-6K Encoder
Heidenhain ROD 426 1000 03S12-03 K 1,00 02 73A01C 64 01 .. MT RV TTL 07 01 ID:376846-DZ Encoder
HEIDENHAIN LS 688 C Sealed Linear Encoder
HEIDENHAIN AK ERM 2980 Modular Angle Encoder With Magnetic Scanning
Heidenhain ROD430-1024(ID:684658-18) Optical Encoder
Heidenhain ROQ 424 512 03S17-58 K 1,00 02 73A01C 64 15 0105 .. G SSI07r1 73 01 .. Absolute Encoder
Heidenhain ERN 1387.025 ID:727221-51 Encoder
HEIDENHAIN TKN ERO 6100 Modular Angle Encoder With Optical Scanning
Heidenhain 1065932-65 Rotary Encoder With Integral Bearing
Heidenhain 811814-14 Encoder
Heidenhain ERN480102468S12-7H Encoder
Heidenhain LC 415 ID:689677-26 Linear Encoder
Heidenhain VBK 03 10 5,00 02B017 03S017-58 BK A007 01 2 .. 0,00 Cable
HEIDENHAIN LIC 4113 Exposed Linear Encoder
Stahl 6161/3-10-421-0-1 Visual Signalling Device
Vulcanic 2377-91 Screw Plug Immersion Heater
Stahl 9182/10-51-64k Temperature Transmitter
Martens GTL 264M Temperature Sensor
Adler EVL31 SOLENOID VALVE
Nuovafima 1.18.1.A.C.---.ABGH.23M Pressure Gauge
Keller PA-23-25 Bar/8465.1 Pressure Switch
Eaton Vickers (Danfoss) KBDG5V-5-33-C-80-N-E-M1-PE7-H-10 Proportional Directional Control Valves
Eaton Vickers (Danfoss) DV4G 3S 8C V M U B5 61 Directional Valve
Fife SE-20 Wide GAP Sensor
Fisher 61 1 Series Pilots
Servomech ATL 20 Mechanical Linear Actuator
Eaton Vickers (Danfoss) 02-353030 FCG 3 180 K 15 Control Valve
Elcis 380QJ A01 - Single turn abs. parallel -SSI - analogic encoder
Gemü Gemü 88574993 1215000Z1110 Indicator
Pizzato FR693-D1 Limit Switch
Air Dimensions R181- Metric R-Series Dia-Vac® Pump Heated Head Hazardous Area
Knf NMP830KPDC-B HP Micro Diaphragm Gas Pump
Micro Detectors C30P/BN-1A Proximity Sensor
JUMO dTRANS p31 – Pressure Transmitter for Increased Medium Temperatures (402050)
Hydropa DS-302/F-150 Pressure Switch
Koso 3800LA Microprocessor Controlled Actuators
Faulhaber 2250S018BX4 Brushless DC-Servomotor
MBS MLI 219 3000 Industrial Crossflo