Need Help? Chat with us on WhatsApp - We're here to assist you!
FAST DELIVERY FROM GERMANY TO WORLDWIDE
hirschmann-5tx-943824-002-railswitch-spider_225406.jpg
hirschmann-5tx-943824-002-railswitch-spider_225406.jpg

Quantity :

Request an Offer

97% customer satisfaction based on last 45 days of sales

Hirschmann 5Tx 943824-002 Railswitch Spider

Ask for Stock

Brand:
Product Code:
5Tx 943824-002 Railswitch Spider

Order Processing & Delivery Information:
As we supply industrial equipment, product availability and delivery timelines may vary. Once your order is placed, our sales team will contact you within 24 business hours (excluding weekends and holidays) to confirm stock status and estimated delivery time.



🎯 Need a Quote for Hirschmann 5Tx 943824-002 Railswitch Spider?

Get the best price and fastest delivery for Hirschmann 5Tx 943824-002 Railswitch Spider from Hirschmann. Imtek Engineering offers worldwide industrial equipment supply with expert support.


Details:

More Interfaces
Power supply/signaling contact1 plug-in terminal block, 3-pin, no signal contact
Network size - Length of cable
Twisted pair (TP)0 - 100 m
Network size - Cascadibility
Line - / star topologyany
Power requirements
Operating voltage9.6 VDC - 32 VDC
Current consumption at 24 V DCmax. 100 mA
Power consumptionmax. 2.2 W; 7.5 Btu(IT)/h at 24 VDC
Service
DiagnosticsLEDs (power, link status, data, data rate)
Ambient conditions
Operating temperature0 C to +60 C
Storage/transport temperature-40 C to +70 C
Relative humidity (non-condensing)10% to 95%
MTBF123.7 years, MIL-HDBK 217F: Gb 25 C
Mechanical construction
Dimensions (W x H x D)25 mm x 114mm x 79 mm
MountingDIN Rail 35 mm
Weight113 g
Protection classIP 30
Mechanical stability
IEC 60068-2-27 shock15 g, 11 ms duration, 18 shocks
IEC 60068-2-6 vibration3.5 mm, 3 Hz - 9 Hz, 10 cycles, 1 octave/min.;
1g, 9 Hz - 150 Hz, 10 cycles, 1 octave/min.
EMC interference immunity
EN 61000-4-2 electrostatic discharge (ESD)6 kV contact discharge, 8 kV air discharge
EN 61000-4-3 electromagnetic field10 V/m (80 - 1000 MHz)
EN 61000-4-4 fast transients (burst)2 kV power line, 4 kV data line
EN 61000-4-5 surge voltagepower line: 2 kV (line/earth), 1 kV (line/line), 1 kV data line
EN 61000-4-6 conducted immunity10 V (150 kHz - 80 kHz)
EMC emitted immunity
FCC CFR47 Part 15FCC CFR47 Part 15 Class A
EN 55022EN 55022 Class A
Approvals
Safety of industrial control equipmentcUL 508
Scope of delivery and accessories
Scope of deliverydevice, terminal block, operating manual
Accessories to order separatelyRail power supply RPS 30, RPS 80 EEC or RPS 120 EEC, 19" installation frame