Need Help? Chat with us on WhatsApp - We're here to assist you!
FAST DELIVERY FROM GERMANY TO WORLDWIDE
hirschmann-9620154-spider-pl-20-08t1s29999ty9-942141-029_647953.jpg
hirschmann-9620154-spider-pl-20-08t1s29999ty9-942141-029_647953.jpg

Quantity :

Request an Offer

97% customer satisfaction based on last 45 days of sales

Hirschmann 9620154 Sp?der-Pl-20-08T1S29999Ty9 942141-029

Ask for Stock

Brand:
Product Code:
9620154 Sp?der-Pl-20-08T1S29999Ty9 942141-029

Order Processing & Delivery Information:
As we supply industrial equipment, product availability and delivery timelines may vary. Once your order is placed, our sales team will contact you within 24 business hours (excluding weekends and holidays) to confirm stock status and estimated delivery time.



🎯 Need a Quote for Hirschmann 9620154 Sp?der-Pl-20-08T1S29999Ty9 942141-029?

Get the best price and fastest delivery for Hirschmann 9620154 Sp?der-Pl-20-08T1S29999Ty9 942141-029 from Hirschmann. Imtek Engineering offers worldwide industrial equipment supply with expert support.


Details:

More Interfaces
Power supply/signaling contact1 plug-in terminal block, 6-pin
USB interface1 USB for configuration
Network size - Length of cable
Twisted pair (TP)0 - 100 m
Singlemode fiber (SM) 9/1250 - 30 km (Link Budget at 1300 nm = 0 - 16 db; A = 0.4 dB/km; BLP = 3.5 ps/(nm*km))
Network size - Cascadibility
Line - / star topologyany
Power requirements
Operating voltage12/24V DC (9.6 VDC - 32 VDC), redundant
Current consumption at 24 V DCMax 200 mA
Power consumptionMax. 5 W, 16.9 Btu (IT)/h
Service
DiagnosticsLEDs (power, link status, data, data rate)
Ambient conditions
Operating temperature-40 C to +70 C
Storage/transport temperature-40 C to +85 C
Relative humidity (non-condensing)10 % to 95%
MTBF (Telecordia)954,743 hours
Mechanical construction
Housing dimensions (w/o terminal block) W x H x D56mm x 135mm x 117mm
MountingDIN Rail
Weight510 g
Protection classIP 40
Mechanical stability
IEC 60068-2-27 shock15 g, 11 ms duration, 18 shocks
IEC 60068-2-6 vibration3.5 mm, 5-8.4 Hz, 10 cycles,
1 octave/min; 1 g, 8.4-150 Hz, 10 cycles, 1 octave/min
EMC interference immunity
EN 61000-4-2 electrostatic discharge (ESD)4 kV contact discharge, 8 kV air discharge
EN 61000-4-3 electromagnetic field10 V/m (80 - 1000 MHz)
EN 61000-4-4 fast transients (burst)2 kV power line, 4 kV data line
EN 61000-4-5 surge voltagepower line: 2 kV (line/earth), 1 kV (line/line), 1 kV data line
EN 61000-4-6 conducted immunity10 V (150 kHz - 80 MHz)
EMC emitted immunity
FCC CFR47 Part 15FCC 47 CFR Part 15 Class A
EN 55022EN 55022 Class A
Approvals
Basis StandardCE, FCC, EN61131
Safety of industrial control equipmentcUL61010-1/61010-2-201
Scope of delivery
Scope of deliverydevice, terminal block, safety instruction