97% customer satisfaction based on last 45 days of sales
Order Processing & Delivery Information:
As we supply industrial equipment, product availability and delivery timelines may vary. Once your order is placed, our sales team will contact you within 24 business hours (excluding weekends and holidays) to confirm stock status and estimated delivery time.
Get the best price and fastest delivery for Hirschmann M?ce Mm3-4Fxm2 943764-101 Ethernet Modul from Hirschmann. Imtek Engineering offers worldwide industrial equipment supply with expert support.
| Multimode fiber (MM) 50/125 µm | 0 - 5000 m, 8 dB link budget at 1300 nm, A = 1 dB/km, 3 dB reserve, B = 800 MHz x km |
| Multimode fiber (MM) 62.5/125 µm | 0 - 4000 m, 11 dB link budget at 1300 nm, A = 1 dB/km, 3 dB reserve, B = 500 MHz x km |
| Power requirements | |
| Operating voltage | Power supply via the backplane of the MICE switch |
| Power consumption | 7W |
| Service | |
| Diagnostics | LEDs (power, link status, data, 100 Mbit/s, full duplex, ring port, LED test) |
| Ambient conditions | |
| Standard operating temperature | 0 C to +60 C |
| Optional operating temperature | -40 C to +70 C |
| Storage/transport temperature | -40 C to +70 C |
| Protective paint on PCB | optional |
| Relative humidity (non-condensing) | 10% to 95% |
| MTBF | 59.5 years; MIL-HDBK 217F: Gb 25 C |
| Mechanical construction | |
| Dimensions (W x H x D) | 38 mm x 134 mm x 118 mm |
| Mounting | Backplane |
| Weight | 180 g |
| Protection class | IP 20 |
| Mechanical stability | |
| IEC 60068-2-27 shock | 15 g, 11 ms duration, 18 shocks |
| IEC 60068-2-6 vibration | 1 mm, 2 Hz - 13.2 Hz, 90 min.; 0.7g, 13.2 Hz - 100 Hz, 90 min.; 3.5 mm, 3 Hz - 9 Hz, 10 cycles, 1 octave/min.; 1g, 9 Hz - 150 Hz, 10 cycles, 1 octave/min. |
| EMC interference immunity | |
| EN 61000-4-2 electrostatic discharge (ESD) | 6 kV contact discharge, 8 kV air discharge |
| EN 61000-4-3 electromagnetic field | 10 V/m (80 - 1000 MHz) |
| EN 61000-4-4 fast transients (burst) | 2 kV power line, 1 kV data line |
| EN 61000-4-5 surge voltage | power line: 2 kV (line/earth), 1 kV (line/line), 1 kV data line |
| EN 61000-4-6 conducted immunity | 3 V (10 kHz - 150 kHz), 10 V (150 kHz - 80 MHz) |
| EMC emitted immunity | |
| FCC CFR47 Part 15 | FCC CFR47 Part 15 Class A |
| EN 55022 | EN 55022 Class A |
| Approvals | |
| Safety of industrial control equipment | cUL 508 |
| Hazardous locations | ISA 12.12.01 Class 1 Div. 2 (pending) |
| Shipbuilding | Germanischer Lloyd |
| Scope of delivery and accessories | |
| Scope of delivery | module, operating manual |
| Accessories to order separately | ML-MS2/MM labels |