97% customer satisfaction based on last 45 days of sales
Order Processing & Delivery Information:
As we supply industrial equipment, product availability and delivery timelines may vary. Once your order is placed, our sales team will contact you within 24 business hours (excluding weekends and holidays) to confirm stock status and estimated delivery time.
Get the best price and fastest delivery for Hirschmann RS2-3TX/2FX EEC 943771-001 Rail Switch from Hirschmann. Imtek Engineering offers worldwide industrial equipment supply with expert support.
| Power supply/signaling contact | 1 plug-in terminal block, 5-pin |
| Network size - Length of cable | |
| Twisted pair (TP) | 0 - 100 m |
| Multimode fiber (MM) 50/125 µm | 0 - 5000 m, 8 dB link budget at 1300 nm, A = 1 dB/km, 3 dB reserve, B = 800 MHz x km |
| Multimode fiber (MM) 62.5/125 µm | 0 - 4000 m, 11 dB link budget at 1300 nm, A = 1 dB/km, 3 dB reserve, B = 500 MHz x km |
| Network size - Cascadibility | |
| Line - / star topology | any |
| Power requirements | |
| Operating voltage | 24 V DC (-25% to +30%) |
| Current consumption at 24 V DC | max. 230 mA |
| Power consumption | max. 5.9 W at 24 V DC |
| Service | |
| Diagnostics | LEDs (power, link status, data, error), signal contact / fault relays (24 VDC / 1A) |
| Redundancy | |
| Redundancy functions | redundant 24 V power supply |
| Ambient conditions | |
| Operating temperature | -40 C to +70 C |
| Storage/transport temperature | -40 C to +85 C |
| Relative humidity (non-condensing) | 10% to 95% |
| MTBF | 43.4 years; MIL-HDBK 217F: Gb 25 C |
| Mechanical construction | |
| Dimensions (W x H x D) | 47 mm x 135 mm x 111 mm |
| Mounting | DIN Rail 35 mm |
| Weight | 320 g |
| Protection class | IP 20 |
| Mechanical stability | |
| IEC 60068-2-27 shock | 15 g, 11 ms duration, 18 shocks |
| IEC 60068-2-6 vibration | 1 mm, 2 Hz - 13.2 Hz, 90 min.; 0.7g, 13.2 Hz - 100 Hz, 90 min.; 3.5 mm, 3 Hz - 9 Hz, 10 cycles, 1 octave/min.; 1g, 9 Hz - 150 Hz, 10 cycles, 1 octave/min. |
| EMC interference immunity | |
| EN 61000-4-2 electrostatic discharge (ESD) | 6 kV contact discharge, 8 kV air discharge |
| EN 61000-4-3 electromagnetic field | 10 V/m (80-1000 MHz) |
| EN 61000-4-4 fast transients (burst) | 2 kV power line, 1 kV data line |
| EN 61000-4-5 surge voltage | power line: 2 kV (line/earth), 1 kV (line/line), 1 kV data line |
| EN 61000-4-6 conducted immunity | 3 V (10 kHz - 150 kHz), 10 V (150 kHz - 80 MHz) |
| EMC emitted immunity | |
| FCC CFR47 Part 15 | FCC CFR47 Part 15 Class A |
| EN 55022 | EN 55022 Class A |
| Approvals | |
| Safety of industrial control equipment | cUL 508 |
| Hazardous locations | ISA 12.12.01 Class 1 Div. 2 |
| Shipbuilding | Germanischer Lloyd |
| Scope of delivery and accessories | |
| Scope of delivery | device, terminal block, operating manual |
| Accessories to order separately | rail power supply RPS 30, RPS 80 EEC or RPS 120 EEC, 19" installation frame |