| Product characteristics |
|---|
| Output signal | switching signal |
| Measuring range [bar] | 0...100 |
| Application |
|---|
| Special feature | Gold-plated contacts |
| Application | for industrial applications |
| Media | liquids and gases |
| Conditionally suitable for | For gaseous media the application is limited to max. 25 bar. |
| Medium temperature [°C] | -25...80 |
| Pressure rating [bar] | 300 |
| Min. bursting pressure [bar] | 650 |
| Type of pressure | relative pressure |
| Electrical data |
|---|
| Operating voltage [V] | 18...30 DC |
| Current consumption [mA] | < 60 |
| Min. insulation resistance [M?] | 100; (500 V DC) |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time [s] | 0.2 |
| Integrated watchdog | yes |
| Inputs / outputs |
|---|
| Number of inputs and outputs | Number of digital outputs: 1 |
| Outputs |
|---|
| Total number of outputs | 1 |
| Output signal | switching signal |
| Electrical design | PNP |
| Number of digital outputs | 1 |
| Output function | normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC [V] | 2 |
| Permanent current rating of switching output DC [mA] | 250 |
| Short-circuit protection | yes |
| Type of short-circuit protection | pulsed |
| Overload protection | yes |
| Measuring/setting range |
|---|
| Measuring range [bar] | 0...100 |
| Set point SP [bar] | 1...100 |
| Reset point rP [bar] | 0.5...99.5 |
| In steps of [bar] | 0.5 |
| Accuracy / deviations |
|---|
| Switch point accuracy [% of the final value] | < ± 1,0 |
| Repeatability [% of the final value] | < ± 0,25; (with temperature fluctuations < 10 K) |
| Temperature drift per 10 K | < ± 0.3 |
| Response times |
|---|
| Switching frequency for a given set response time of one output | | Response time (dAP) | [ms] | 3 | 6 | 10 | 17 | 30 | 60 | 125 | 250 | 500 | | Switching frequency | [Hz] | 170 | 80 | 50 | 30 | 16 | 8 | 4 | 2 | 1 |
|
| Response time [ms] | at rectangular pressure characteristic; switch point (SPx) = 70 %; reset point (rPx) = 30 % |
| Delay time programmable dS, dr [s] | 0, 0,2,...10, 11,...50 |
| Software / programming |
|---|
| Adjustment of the switch point | programming button |
| Parameter setting options | hysteresis / window; normally open / normally closed; switch-on/switch-off delay; Damping |
| Operating conditions |
|---|
| Ambient temperature [°C] | -25...80 |
| Storage temperature [°C] | -40...100 |
| Protection | IP 67 |
| Tests / approvals |
|---|
| EMC | | EN 61000-4-2 ESD | 4 kV CD / 8 kV AD | | EN 61000-4-3 HF radiated | 10 V/m | | EN 61000-4-4 Burst | 2 kV | | EN 61000-4-6 HF conducted | 10 V |
|
| Shock resistance | | DIN IEC 68-2-27 | 50 g (11 ms) |
|
| Vibration resistance | | DIN IEC 68-2-6 | 20 g (10...2000 Hz) |
|
| Mechanical data |
|---|
| Materials | EPDM/X; FKM; PA; PBT; PC; stainless steel (1.4301 / 304) |
| Materials (wetted parts) | stainless steel (1.4305 / 303); ceramics; FKM |
| Min. pressure cycles | 100 million |
| Displays / operating elements |
|---|
| Display | | switching status | LED, red | | function display | 7-segment LED display | | measured values | 7-segment LED display |
|
| Remarks |
|---|
| Pack quantity | 1 pcs. |
| Electrical connection |
|---|
| Connection | Connector: 1 x M12; Contacts: gold-plated |