Get the best price and fastest delivery for NSD VS-12PB VARILIMIT Positioning Output Controller from NSD. Imtek Engineering offers worldwide industrial equipment supply with expert support.
VS-12PB-M2RDVS-12PB-M2PGD-R3VS-212DN-R3VS-12PB-M2PGD-R3R-VS-12PA-21-R3
| Code | Absocoder Sensor |
|---|---|
| M2PG | MRE-32SP062/MRE-G?SP062(? : 64/128/160/256/320) |
| L | VLS-256PWB/VLS-512PWB/VLS-1024PW |
| Code | Specification |
|---|---|
| Blank | None |
| D | With external BCD I / O |
| Item | Specification |
|---|---|
| Power supply voltage | 100VAC 50/60Hz |
| Permissible power voltage rangen | 85 ? 132VAC |
| Power consumption | 15VA or less |
| Ambient operating temperature | 0 ? +55?(No freezing) |
| Ambient operating humidity | 20 ? 90 %RH (No condensation) |
| Insulation resistance | 20M? or more between external AC power terminals and ground (by 500 VDC insulation resistance tester) |
| Withstand voltage | 1500 VAC, 60Hz for 1 minute |
| Vibration resistance | 20m/s2 {2G} 10 ? 500Hz, 10cycles of 5 minutes in 3 directions, conforms to JIS C 0040 standard |
| Mass | 2.0 Kg |
| Items | Specifications | ||||||
|---|---|---|---|---|---|---|---|
| Controller model | VS-12PB-M2PG VS-12PB-M2PGD | VS-12PB-L VS-12PB-LD | |||||
| Applicable sensor | MRE-32SP062 | MRE-G?SP062 | VLS-256PWB,VLS-512PWB, VLS-1024PW | ||||
| Position detection format | Absolute position detection | ||||||
| Number of divisions | 4096 Division × 32 Turns ? 409.6 Divisions × 320 Turns | - | |||||
| Resolution | - | VLS-256PWB:0.00391mm VLS-512PWB:0.00781mm VLS-1024PW:0.0156mm | |||||
| Number of detection axes | 1 | ||||||
| Data setting method | Key input at panel, communication, external BCD input | ||||||
| Positioning function | Control format | Unidirectional positioning or Bidirectional positioning | |||||
| Control output | Forward (FWD), Reverse (RVS), High-speed, Low-speed, Brake release, In-position, Positioning in progress, Operation error | ||||||
| Switch output function | Number of programs | 1 | |||||
| Number of switch outputs | 8 | ||||||
| Number of multi-dogs | 10 times for each switch output | ||||||
| Sampling time | Switch output Positioning output | 1ms | |||||
| Current position output | n × 4ms(n = 0 ? 64 by parameter setting) | ||||||
| Setting value memory | Non-volatile memories (EEPROM) | ||||||
| Auxiliary functions | Current position detection, positioning function, switch outputs, protected switches, current position preset, JOG operation, Self-diagnosis | ||||||
| Max. sensor cable length | Standsrd(s) | 100m | 100m | 100m | |||
| Robotic(RBT) | 40m | 70m | 50m | ||||
| Item | Input specifications | |
|---|---|---|
| Input signals | Start signal, etc. ...10 points | Target stop position BCD input...26 points |
| Input circuit | DC input, photo-coupler isolation | |
| Input logic | Negative logic | |
| Rated input voltage | 24VDC | |
| Rated input current | 10mA | |
| Voltage range to be used | 20.4V ? 30VDC | |
| ON voltage | 12 VDC or more | |
| OFF voltage | 4 VDC or less | |
| Output signals | Control output...19 points | Current position BCD output...26 points |
| Output circuit | Transistor (open-collector), photo-coupler isolation | |
| Output logic | Negative logic | |
| Rated load voltage | 24 VDC (30 VDC Max.) | |
| Max. load current | 100mA | |
| Max. voltage drop when ON | 0.5V or less | |