im-tek.com

NSD VS-5FX-1 VARICAM Cam Switch Output Controller

NSD

Product Code: VS-5FX-1 VARICAM
Brand: NSD



GET OFFER: info@imtek.com.tr

Description for NSD VS-5FX-1 VARICAM Cam Switch Output Controller

Model codingVS-5F[1][2]-[3][1]No. of programs×No. of switch outputs , and othersCodeOutput codeBlank1 program×24 switchesD8 programs×24 switches, current position BCD output.X16 programs×40 switches or 32 programs×24 switches, current position BCD output.[2]Output systemCodeOutput systemBlankSink type[3]Power supply voltageCodeSpecification124VDC.ABSOCODER Basic Configuration SpecificationGeneral specificationItemSpecificationConverter modelVS-5F-1VS-5FD-1VS-5FX-1Power supply voltage24VDCPermissible powervoltage range21.6 ? 30VDCPower consumption10W or lessInsulation resistance20M? or more between external AC power terminals and ground(by 500 VDC insulation resistance tester)Withstand voltage500 VAC, 60Hz for 1 minutebetween external DC power terminals and groundVibration resistance20m/s2 10 ? 500Hz, 10cycles of 5 minutes in 3 directions,conforms to JIS C 0040 standardAmbient operatingtemperature0 ? +55? (No freezing)(Surrounding air temperature rating of 55? maximum)Ambient operatinghumidity20 ? 90 %RH (No condensation)Ambient operatingenvironmentFree from corrosive gases and excessive dustAmbient storagetemperature-10 ? +70?GroundingMust be securely grounded (ground resistance of 100 ohm or less)ConstructionInside control panelMountingSelect from two-screw mounting/DIN rail installation/on-panel mounting using panel mounting fixture VS-K-F.Outside dimension (mm)130(W)×81(H)×99(D)MassApprox. 0.7kgPerformance SpecificationItemSpecificationConverter modelVS-5F-1VS-5FD-1VS-5FX-1Applicable sensorVRE-P028,VRE-P062Min. setting units0.5°Number of programs (Panel display)18(0 ? 7)16(0 ? 15)32(0 ? 31)Number of switch outputs24244024Number of multi-dogs10 times for each switch output (0 ? 9)Position data sampling time(permissible speed)0.176ms (900 r/min When ON / OFF range is 1 degree)Switch output setting methodNumerical setting from the panel or teachingSetting value memoryNon-volatile memories (FRAM)Error detectionSensor power error, Sensor error , Memory error , No setting error , Setting impossible error , System errorAuxiliary functionsProtected switch???Setting changeduring operation???Current position value(BCD, gray code(720-division))-??Binary speed output-Selectable between current position output and speed outputSelectable between current position output and speed outputTiming pulse output???Motion detection switchSelectable between timing pulse and speed detection outputSelectable between timing pulse and speed detection outputSelectable between timing pulse and speed detection outputSwitch output enable???Hysteresis???Exterminal origin set--?Arbitrary pulse output???Current position HOLD-??Error cancel???Password???Communication functionSerial (RS-232C) communication (setting value saving or loading, monitoring, operation commands)Connection by Mitsubishi-only protocol/MELSEC-A protocolConnection with angle display unit (NDP) is also possibleConnection by OMRON-only protocolConnection with touch panel is possible (VARIMONI)Connection ofan external display unitI/O connection-??Communicationconnection???Max. sensorcable lengthStandard100mRobotic(RBT)100mI/O spcificationItemVS-5F-1VS-5FD-1VS-5FX-1DescriptionInputsignalsProgram No.-3 points4/5 pointsInputs the exteral program No.Current position HOLD-1 point-Used to prevent the current position value from changing when controller reading occurs.Current position HOLD orexternal origin set--1 pointInput to prevent current position from changing or for origin setting.Error cancel1 point1 point1 pointInput to cancel an error display.Switch output enable1 point1 point1 pointSwitch signal will be output only upon the input of this signal.OutputsignalsSwitch output /Arbitrary pulse output24 points24 points40/24 pointsON/OFF signal will be output based on the switch setting value, or pulse signalwill be output based on equally dividing a single rotation (division selectable from 1 ? 360).Timing pulse /Motion detection switch1 point2 points1 point60, 180 or 360 pulse signals will be output per rotation, or ON/OFF signal will be output based on the speed setting value.System ready1 point1 point1 pointOutputs when controller and sensor are functioning normally.Program No.-3 points4/5 pointsThe currently selected Program No. is output.Current position value(BCD, gray code(720-division)) /Speed Binary output-11 points11 pointsCurrent position (3-digit BCD + 0.5-deg display) signal will be output, or rotational speed will be output in binary code.Latch pulse-1 point1 pointOutputs a timing signal which ensures that the current position is read in a stable condition.ItemInput specificationsItemOutput SpecificationsInput signalsProgram No.External origin setCurrent position HOLDError cancelSwitch output enableOutput signalsSwitch output or arbitrary pulseProgram No. Sysytem readyMotion detection switch or timing pulseCurrent position value (BCD, gray code (720-division)) or speed (binary)latch pulseInput circuitDC input, photo-coupler isolationOutput circuitTransistor (open-collector), photo-coupler isolationInput logicNegative logicOutput logicNegative logicNegative logicPositive logic*1Rated input voltage

Recommended Products For NSD


NSD MRE-32SP101LKR5-G Absocoder Sensor
NSD HPM-34 Proximity Sensor
NSD 4P-S-0102-100 Extension Cable
NSD 3P-RBT-0102-40 Extension Cable
NSD VM-2CC Converter
NSD Absocoder Cutout Sample
NSD VS-10G-D-1 VARILIMIT Limit Switch Output Controller
NSD NCV-20NGNLP Converter
NSD 4P-S-0102-90 Extension Cable
NSD 3P-S-0102-30 Extension Cable
NSD VS-5F Varicam Switch System Controller
NSD VRE-P028SAC Sensor
NSD 4P-S-0102-25 Encoder Cable
NSD GPS-C01-20 Extension Cable
NSD 4P-S-0102-10 Encoder Cable
NSD NDP-A221B1 External Display Unit for VARICAM
NSD GTA-120VN EZGAP Converter
NSD MRE-G256SP062FACM Encoder
Elomatic FS0200.NU40CWALT.NL22SNA.00XX Pneumatic Actuator
Moxa TCF 142MST RS 232/422/485 Converter
KSB ETN 125-100-400 GB P1CGA5 B Pump
Kiepe Hen 002 91043450002 Pull-wire Emergency Switch
Eurotherm 2500T/DO16//NONE//XXXXX/XXXXXX/ 16 Ch Digital Output Card Terminal Eurotherm 2500T/DO16//NONE//XXXXX/XXXXXX/ 16 Ch Digital Output Card Terminal
Kadant 995.595/0007 RX Rotary Union
Moog G771K226A Servo Valve
Stauff 6048.3-PP-SIP-AF-M-W2-K 1110010284 Clamp Combination
Alfa Laval 9613360590 UNIQUE SSV 51/2 INCH 220 W-W 0.8/BLASTED EPDM CHANGE OVER NO ASEPTIC
VIMARC DDP 201-4 Vibrator motors
Goldammer TR G2-T1-FE-300-VA-II-3+PE Temperature-capillary tube-regulator
Ayvaz SISKF-50 Gimbal Type Expansion Joint
Kadant 995.166/0001 RX Rotary Union
Trafag MS...R 630/632 Mini Limistat
Steimel SF 6/132 RD BZP056132RD--151R Gear Pump
Franz Kessler DMS 112-609.147 Milling Spindles
Parker DF2089110QVPXX604 Duplex Filter
WENGLOR SL2-00NE000H3 Safety Through-Beam Sensor
Edur BC25-201/0157-2900 Single Stage Close-Coupled Pump
Topworx 75-13528DCA - SPDT, End Sensing, UL GP, 3-Pin, 303 Stainless Steel, Model 75 GO Switch
Mp Filter HP0394A10ANP01 Filter
Tecsis F2802 Tension/Compression Force Transducer
Spirax Sarco M10S Ball Valve
Vega CP-E.60RX Electronics VEGACAP series 60 EID: TR133397 Electronic Circuit