Calculate accurate inventory volumes by integrating temperature measurement into your tank gauging system. Product temperature is used for volumetric calculation to a reference temperature and is of significant importance in the accurate calculation of liquid inventories in bulk storage tanks.Specifications
Resistance Bulb
Platinum (DIN 385) 100 Ohms at 32 °F (0 °C)
Probe Lengths
18” (45.7 cm)
24? (61 cm)
36” (91.4 cm)
48” (122 cm)
316SS Thermowell Process Connection
¾” male NPT
1” male NPT, 36” length (other lengths available upon request)
1½” 150 lb ANSI/ASME RF flange
1½” 300 lb ANSI/ASME RF flange
All thermowells have a ½” female NPT connection for RTD probes.
The bore on all thermowells is 0.260” for ¼” diameter probes.
Thermowells are available in different material types upon request.
Other thermowell flange sizes and ratings available upon request.
Thermowell Custom Additional Options
Wake Frequency Calculation
Hydrostatic Test
Full Penetration Welds
NACE Certified
Material Certificates
Positive Material Identification (PMI)
Plug & Chain; 304SS, 316SS, Brass
Ra 20 max Special Surface Finish
Coatings; Tantalum/ Halar, PFA, PTFE, Tungsten Carbide
Custom Stamping
Measuring Temperature Range (inside the tank)
Higher range ?328 to 1100 °F (?200 to 593 °C) available upon request
Operating Temperature Range (outside the tank)
?40 °F and +185 °F (?40 °C and +85 °C)
Enclosure Approvals
Rated IP65 (NEMA 4)
FM / FMC Approval: Class I, Div 1, Groups A,B,C,D Class II, Div 1, Groups E,F,GOptions
01 Connection Type
¾” male NPT
1” male NPT, 36”
length (other lengths available upon request)
1½” 150 lb
ANSI/ASME RF flange
1½” 300 lb
ANSI/ASME RF flange
Special Version
(Contact Factory)
02 Probe
Length
18? (45.7 cm)
24? (61 cm)
36? (91.4 cm)
48? (122 cm)
Special Version
(Contact Factory)
03 Element
Type
100 Ohm Platinum
DIN385 Element, -328°F to 1100°F (-200°C to 593°C)
100 Ohm Platinum
DIN385 Element, -328°F to 1100°F (-200°C to 593°C), in-head HART
transmitter
Special Version