im-tek.com

Biolab Miniflash Touch Flash Point Analyzer

Biolab

Product Code: Miniflash Touch
Brand: Biolab



GET OFFER: info@imtek.com.tr

Description for Biolab Miniflash Touch Flash Point Analyzer

MINIFLASH TOUCH is a uniquely designed flash point tester for the determination of flashpoints of liquids and solids, using the Grabner flash point detection method of measuring the instantaneous pressure increase inside the continuously closed chamber, triggered by an energy-controlled electric arc. Heating the test chamber from the top avoids condensation of high volatile compounds, significantly improving the test results. Its continuously closed cup design and small sample volume of only 1-2 mL offers maximum safety, avoids offensive fumes in the testing area and reduces sample waste. The fast thermoelectric cooling at the end of a test and the fast and easy handling of the instrument save expensive labor time. The full color touch-screen of the MINIFLASH TOUCH runs on Microsoft® Windows® software and features an intuitive menu navigation that requires no training for flashpoint testing. Along with its convenient touch screen design, the MINIFLASH TOUCH offers an extended temperature range from 0 to 400°C, hassle-free communication with USB, Ethernet, LIMS and PCs and nearly unlimited storage capacity for programs and results. MINIFLASH determines the flash point according to ASTM D6450 and according to the advanced ASTM D7094 standard. This procedure describes the “Standard Test Method for Flash Point by Modified Continuously Closed Cup (MCCCFP)”, which offers the highest repeatability and reproducibility and an excellent correlation to the D93 Pensky-Martens method: “There is no statistically significant bias observed between ASTM D7094 and ASTM D93 Procedure A” as concluded during the last Round Robin. Furthermore, test results are equivalent to other well known standards such as Abel and TAG, and thanks to its unique design MINIFLASH can be used for more difficult applications such as flash-point testing of contaminated samples like diesel fuel in lube oil or gasoline in diesel fuel and for biodiesel testing. The new MINIFLASH TOUCH analyzer also includes improved methods for simulation of EN ISO 3679 and EN ISO 3680. Due to true portability and rugged housing, the MINIFLASH TOUCH is also the perfect solution for mobile labs and military applications. Features Flashpoint according to ASTM D6450 (Flash-Point by Continuously Closed Cup) and ASTM D7094 (Flash-Point by Modified Continuously Closed Cup) FLASHPOINT COMMITTEE STATEMENT: “There is no statistically significant bias observed between ASTM D7094 and ASTM D93 Procedure A.”), equivalent EN ISO 2719, excellent correlation to ASTM D56, ISO13736, IP170 New methods for EN ISO 3679 and EN ISO 3680 simulation Dilution Flashpoint Testing Go / No Go Flashpoint Testing Fast Screening Methods Automatic ignition cleaning method Maximum safety through Grabner continuously closed cup method (Ignition Protection Technology™) 1-2 ml sample size * No Open Flame, no offensive vapors in the lab * Highest accuracy (see precision statement) Extended temperature range: 0 to 400°C with external cooling (MINIFLASH FLPH TOUCH) Fully remote operable * Big, color touch-screen for convenient, intuitive menu navigation Touch Screen Runs on Microsoft® Windows®: Full integration with network, LIMS and PC Hassle-free communication and data transfer via USB and Ethernet USB printer support Good Laboratory Practice: User Access Control Portable for Mobile and Field Use (car battery connector) Worldwide standard method for the flavors and fragrances industry Approved for the ASTM specifications of recycled fuel and biodiesel Short measuring time (depends on sample type) due to small sample volume of 1-2 ml Combustion Analysis™ Excellent thermoelectric heating and cooling regulation through Peltier Protection Technology™ Specifications MINIFLASH FLP TOUCH: 0 to 200 C (32 to 390 F) MINIFLASH FLPH TOUCH: 0 to 400 C (32 to 750 F) MINIFLASH FLA/FLAH: With 8 sample capability autosampler Power Requirements: 100/110/230 V AC, 50/60 Hz, 150 W

Recommended Products For Biolab


Biolab Miniflash Touch Flash Point Analyzer
Biolab MiniLab 53 Oil Analysis System
Biolab Filmdist TF 650 Thin-Film Evaporation
Biolab PETRODIST 100 Crude Oil Distillation System
Biolab Calidus Gas Chromatograph
Biolab TC40 Copper Corrosion Of Aromatic Hydrocarbons
Biolab TLC Series Manuel Cloud And Pour Point Analyzer
Biolab AR9 Refractometer
Biolab Filmdist SP 200 Shorth Path Evaporator
Biolab TLC 15 Hydrometer Method Density Meter
Biolab CoolCheck® 2 Coolant And Diesel Exhaust Fluids (DEF) Analysis System
Biolab Filmdist SP 500 Shorth Path Evaporator
Biolab MINIDIS ADXpert Automatic Mint-Distillation System
Biolab PETRODIST 300 Crude Oil Distillation System
Biolab PETRA EDXRF Sulfur Analysis System
Biolab TB 30 LPG Copper Corrosion
Biolab Aquamax KF Water Content Analyzer
Biolab PETRODIST 200 Crude Oil Distillation System
Pressure Tech LF310 Analyser & Instrumentation Regulator
Elwa 46128RF-V Flowheater
Schroedahl Type TDM Pump protection Valve for Centrifugal Pumps
Wilkerson F18-02-SGVO Particulate Filter
Cemb T1-C Multichannel Modular System for Vibration Monitoring of Tunnel Fans
Gefran Type: 600-R-D-C-2-1 Code: F026395 Process Controller
Vogel MKU11-KW2-0005 428 Single Line Pump
Kadant GB012018360 G Rotary Union
Officine Orobiche TGO 65 Flow Alarm Switch
Goyen CA40T Control Valve
Fortress Interlocks SLS Solenoid Controlled Key Switch
Grundfos CRN20-08 A-FGJ-G-E-HQQE Pump
Vulcanic 2114-31 Screw Plug Immersion Heater
Air Dimensions B162 Elevated B-Series Head Dia-Vac® Pump
Nuovafima 1.Om.3.A.E.---.Aaga.S38.Mc3.Mcf Homogenizer Pressure Gauge
Vulcanic 2321-04 Screw Plug Immersion Heater
Meidinger 160-9 Blower
FIP Italy VKDIC Series DN 10÷50 DUAL BLOCK® 2-way Ball Valve
Meister M21400 Flowmeter
Gefran F052376/GTF-25-480-0-0-0-0 1-B-M Power Controller
Watson-Marlow 050.9131.2LE Pump
Bollfilter Ident-Nr.1143105 Filter Element
Eltra EL63F2000S5/28P12X3JR (91297276) ENCODER
Atlas Copco 0663212120 O-ring 66.27x3.53