im-tek.com

Biolab TC16 Silver Corrosion System

Biolab

Product Code: TC16
Brand: Biolab



GET OFFER: info@imtek.com.tr

Description for Biolab TC16 Silver Corrosion System

TC16 circulator with temperature range from ambient to 250°C, 230V-50Hz~60Hz, temperature stability ± 0.02°C. Bath conforms to ASTM D4814, ASTM D7667, ASTM D7671, IP 227, and IP 611. It is equipped with a cover with six holes and lids for six test stations. Methods specify the determination of the corrosive tendencies towards silver, of aviation turbine fuels, automotive spark-ignition engine fuels, or automotive gasoline. The result is classified as an integer in the range 0 to 4. Technical Data Weight [kg] 21 Mains 230V-50Hz~60Hz Test Method ASTM D4814, ASTM D7667, ASTM D7671 Other Test Methods IP 227, IP 611 Bath Temperature Accuracy [± ] 0.02°C Maximum Temperature 250°C Minimum Temperature 5°C Bath Volume 16 litre Bath Width 295 Bath Height 440 Bath Length 455 Bath Opening 6 x 51

Recommended Products For Biolab


Biolab Filmdist SP 500 Shorth Path Evaporator
Biolab TC16 Copper Corrosion Analyzer
Biolab AR9 Refractometer
Biolab TC40 Copper Corrosion Of Aromatic Hydrocarbons
Biolab Parafuel Nir In-line Analyzer
Biolab Filmdist TF 650 Thin-Film Evaporation
Biolab PETRODIST 200 Crude Oil Distillation System
Biolab PETRODIST 100 Crude Oil Distillation System
Biolab D70 Densitymeter
Biolab Polar Series Polarimeter
Biolab TLC 15 Hydrometer Method Density Meter
Biolab SpectroT2FM Q500 Laboratory Ferrography
Biolab CoolCheck® 2 Coolant And Diesel Exhaust Fluids (DEF) Analysis System
Biolab Spectro LNF Q200 Series Particle Counter & Shape Classifier
Biolab MicroLab All-in-one Automated Lubricant Analysis System
Biolab PORLA Stability Analyzer
Biolab Phoebe M Series Phosphorus Analyzer
Biolab DENSITY 4/5 Density Meter
Winsmith U3010S56 RD Speed Reducer
Joyce/Dayton HD625 Actuator
Abo Valve 2E-5570B100 LEVER
Atos DHZO-TEBSNNP-071-L5 Valve
Rotork Serial :SF P/N : SF60281-20A11A30008 Limit Switch Box
Eaton 199314 Auxiliary Contact Block
Goldammer IND-GB-113-1, Indicator - L - 2 - R - 150 °C max. (remote installation) Level controller with PNP level outputs
Micro Detectors BX10S/X0-AB Area Sensor
Pizzato Cs Mp201M0 Safety Relay
Scherzinger 3040-045-B-ZK71-140 Hastelloy (R) Gear Pumps 3040
Yuken DSG-01-2B2-A220-51T Valve
Tokimec SM1 Pressure Switch Valves
Boschert FLO-30-40-VT2-AB38 Vt-chuck
Grundfos NB150-315/336 A-F-A-BAQE Pump
Air Dimensions H-Series Dia-Vac® Pump Single Head Hazardous Area
Sumitomo Fine Cyclo UA-Series Motion Control
ETP EXPRESS 48 Hub-Shaft Connection
Senseca ATEX A-H1.1-489125 Atex Switching Unit Atex A
Vulcanic 2218-08 Screw Plug Immersion Heater
Dafram 150RC Ball Valve
Stauff SMK-20-G1/4-B-C-W3 Coupling
Woerner GFZ-D Gear-type pump
Eaton KDG4V3S33C08AMUH560 Valve
Asco SG110A051.24/DC Complete Solenoid Valve