德国快速配送至全球

Aoip CALYS 50 Field Instruments


Aoip CALYS 50  Field Instruments Image

您对制造商Aoip的产品Aoip CALYS 50 Field Instruments,代码为CALYS 50感兴趣吗?立即联系我们获取报价。Imtek Engineering,世界上最快最可靠的工业设备供应商,将为您提供最佳报价!

Get Offer With E-Mail: info@im-tek.com
Get a offer for Aoip CALYS 50 Field Instruments from our live support team now!

CALYS 50 is a basic multifunction calibrator within CALYS range. It is the perfect tool for advanced process maintenance and use on test bench in all industries. Suitable for all field and lab measurements, it can simultaneously measure and generate over two isolated channels various signals of temperature, resistance, process and frequency in one single instrument.It provides extended functionalities (temperature simulation, scaling, steps, synthesizer, statistical functions…), easily accessible through quick menus by function.The instrument simultaneously measures and simulates:Temperature: Up to 0,014% RDGResistance: Up to 0,012% RDG, 4 K? rangeCurrent: Up to 0,0175% RDG, 50 mA range + 24 V loop supplyVoltage: Up to 0,013% RDG, 50 V IN / 20 V OUT rangeFrequency: Up to 0,005% RDG, 20 KHz range (10 KHz in simulation)IP 54, fully protected by an antichoc rubber holster, CALYS 50 integrates "easyconnect" terminals and a wide backlite display that makes it easy to use in any severe or dark conditions.Easy connection systemConnect your probes by simply pushing on the terminal top and insert wires of up to 3 mm or 10 AWG diameter and compensated thermocouple connectors.Wires are held tight between two brass plates ensuring thermal stability and a very good cold junction compensation for thermocouples.This system also enables 4 mm banana plugs and security connectors to be connected on the terminal top.CALYS series, 4 models from basic use to advanced performances Specifications CALYS 50 CALYS 75 CALYS 100 CALYS 150 Top accuracy 200 ppm 130 ppm 50 ppm Temperature accuracy Thermocouples (14) RTDs (12) 0.013% RDG for Tc K 0.012% RDG 0.01% RDG for Tc K 0.01% RDG 0.005% RDG for Tc K 0.006% RDG DC current + Loop supply 24 V Range Accuracy 50 mA 0.0175% RDG 100 mA 0.007% RDG DC voltage Range Accuracy 50 V IN / 20 V OUT 0.013% RDG 50 V 0.010% RDG 50 V 0.005% RDG Frequency Range Accuracy 20 KHz IN / 10 KHz OUT 0.005% RDG 100 KHz 0.01% RDG Resistance Range Accuracy 4000 ? 0.012% RDG 4000 ? 0.010% RDG 50 K? 0.006% RDG Pressure Range Accuracy Relative pressure: 30 bar / Absolute pressure: 1,000 bar 0.05% RDG Compliance to standards 21 CFR Part 11 NADCAP Heat treatment AMS 2750 Additional functions Advanced data exploitation: Scaling, relative measurement, simulation of ramps and steps, synthetizer, square root, statistical functions Transmitter function Additional functions Switch test Calibration of transmitters Additional functions Comparison calibration HART: Digital calibration and data transfer Calibration of thermistors Software DATACAL calibration software for configuration and data management Memory 10,000 data stored and recalled on screen as curve or list