im-tek.com

Biolab PORLA Stability Analyzer

Biolab

Product Code: PORLA
Brand: Biolab



GET OFFER: info@imtek.com.tr

Description for Biolab PORLA Stability Analyzer

Porla Analyser can analyse heavy and crude oils that cover extremely wide viscosity and asphaltene content ranges from very high to very low. Very often, low asphaltene content oils cause blending and process problems. In addition, the new Porla has an analysis programme for blending the parameter of asphaltene free oils and blend components. Furthermore, Porla is perfectly suited to the analysis of bitumen. Porla will report a comprehensive set of stability and compatibility parameters such as P-value, Pa, Po, FR5/1(toluene/xylene equivalent), FRmax, In and Sbn all in one operation.  As a result of the exceptionally wide applicability area, Porla will result in the biggest benefits and profitability increases to end-users. The unique detector technology of New Generation Porla, based on the reflection of asphaltene sensitive light, facilitates the applying of a low dilution of oil samples, resulting in the accurate analysis of oils containing as little as 0.1% asphaltene and sometimes even lower. Other particles besides asphaltenes, such as coke, do not disturb the Porla analysis. Therefore, the removal of coke prior to analysis is not necessary. New Generation Porla is a very useful and practical tool for planning and monitoring the blending of feedstocks/crude oils, heavy oil blending (from cracking bottoms and solvents), the blending of bitumen and optimisation of cracking units (e.g. thermal and hydrocracking) of oil refineries. In addition, New Generation Porla can also be used for monitoring visbreaking processes and the dilution of tar sands with light ends in the production fields of tar sand crudes. Besides its unique performance in analysing the stability and compatibility parameters of low asphaltene content oils, the New Generation Porla Analyser includes an automatic procedure for analysing the ExxonMobil heavy and crude oil blending model parameter Sbn (solubility blending number) of asphaltene free oils and blend components. We have made the New Generation Porla operation easy for end-users. Operation of the analysis programme is very simple and easy. The programme gives default values to the operator to prepare the stock solution, and there is no need to prepare more than one stock solution from oil to be analysed and an aromatic solvent. We offer strong application development support for Porla end-users when commissioning the analyser at a customer site/laboratory. Our expert will remain at the customer’s laboratory for 4-5 days to give user-training and run a wide range of oil samples with the operator, which can be analysed in the laboratory. He will also give instructions concerning sample preparation and the running parameters of these oils. As a result of this service, the end-user has ready applications for different oil types and an understanding on how to built applications for possible new oil types. This service will ensure a smooth start for new Porla end-users. Sometimes, some new oils to be analysed might seem challenging or the analysis results may look a bit peculiar. For those situations, we have a special service for our Porla users. The only thing the Porla end-user needs to do is send a sample to our application laboratory in Finland. We will analyse the sample free of charge in our laboratory, report the results and give instructions on how the oil sample can be prepared and successfully analysed in the future. The only cost that the end-user must pay is the transportation of the sample to our laboratory.

Recommended Products For Biolab


Biolab Filmdist SP 200 Shorth Path Evaporator
Biolab SINDIE 7039 G3 Sulfur Analyzer
Biolab CoolCheck® 2 Coolant And Diesel Exhaust Fluids (DEF) Analysis System
Biolab TC40 Copper Corrosion Of Aromatic Hydrocarbons
Biolab Spectro LNF Q200 Series Particle Counter & Shape Classifier
Biolab TLC Series Manuel Cloud And Pour Point Analyzer
Biolab PETRODIST 100 Crude Oil Distillation System
Biolab TB 30 LPG Copper Corrosion
Biolab Miniflash Touch Flash Point Analyzer
Biolab PAT940 TAN/TBN Analyzer
Biolab MINISCAN IRXpert Gasoline Diesel And Jet Fuel Analyzer
Biolab Spectroil Q100 Oil & Fuel Elemental Analysis Spectrometer
Biolab Calidus Gas Chromatograph
Biolab M Series Signal Silicon Analyzer
Biolab DENSITY 4/5 Density Meter
Biolab Clora M Series Chlorine Analyzer
Biolab Parafuel Nir In-line Analyzer
Biolab Q6000 FDM Series Fuel Dilution Meter
Micro Detectors C18P / A0-1E Proximity Sensor
MAC 116B-611JD 2005 Selenoid Valve
Franz Kessler SMS 080-630.583 Milling Spindles
Eaton Vickers (Danfoss) SV2-20-G0-00 Valve
Kirchgaesser TEMEX Temperature Meter with Local Display
KWD TK-N-AVZ-GMK 560 - 65 H7 x 140 - 70 H7 x 140 - KWN 29000 Coupling
Leybold 140117S Dust Filter Element
Eaton DU63-0010 Duplex Filter
Scherzinger 4050-450-DM-25-6 Titanium Gear Pumps 4050
Leine Linde RSI 504 Ruggedized R Shaft encoder
Scherzinger 4050-280-B-DM-12-8 Titanium Gear Pumps 4050
Eaton SV13 10 C0 24DGH 2/2 132LT-310 BAR Valve
Faggiolati G471T6V1-L50AA0 Pump
Kelvion GK... 770H Brazed Plate Heat Exchangers
Kieselmann 511X S-S KI-DS Control Valve Linear Actuator
Martens LF4433 Conductivity Measuring Cell
Air Dimensions B162 Elevated B-Series Head Dia-Vac® Pump
Pferd 42750212 Combidisc Cd 20 A 120
Pall UR649CF6440ZN Duplex Filter
Metalwork 4583009U FR 300 3/4 50 012 RMSA
Santerno Sinus Penta Inverter
Ru-Steel RSP 2000 RSP 8 Bolt Range with Spacer and Adaptors
Kelvion GBS 800H-AE Brazed Plate Heat Exchangers
Megger TPT320 Voltage Tester