Produktname: Bopp Reuther DIMF 1.3 Density and Concentration Meter
Marke: Bopp Reuther
Produktcode: DIMF 1.3
Stichwörter: Bopp Reuther
Bopp DIMF 1.3 Density Concentration Meter
Reuther DIMF Density Concentration
Bopp DIMF Density and Concentration Meter
Reuther DIMF and Meter
1.3 and Meter
Bopp Concentration
Bopp Density and Meter
Bopp DIMF Density and Concentration Meter
DIMF Density and
Bopp 1.3
Bopp DIMF 1.3 Density and Concentration
Reuther Meter
DIMF Density Meter
Concentration Meter
Reuther DIMF 1.3 and Meter
Bopp Reuther DIMF 1.3
Bopp 1.3 Concentration Meter
Bopp DIMF 1.3 Density Concentration Meter
DIMF Meter
1.3 and
Density and Concentration Meter
Interessieren Sie sich für das Produkt Bopp Reuther DIMF 1.3 Density and Concentration Meter vom Hersteller Bopp Reuther mit dem Code DIMF 1.3? Kontaktieren Sie uns jetzt und holen Sie sich ein Angebot. Imtek Engineering, der schnellste und zuverlässigste Lieferant von Industrieausrüstung der Welt, wird Ihnen das beste Angebot machen!
Angebot per E-Mail erhalten: info@im-tek.com
Holen Sie sich jetzt ein Angebot für Bopp Reuther DIMF 1.3 Density and Concentration Meter von unserem Live-Support-Team!
TECHNICAL DATA Nominal size 10mm Process connection Internal thread G ¼ ISO 228 Flanges DN10 according to pressure stage PN 40 (or Class 150/300 RF) according to DIN 2501 (or ANSI B 16.5) Other pressure ratings available on request Material Special alloy NiFeCr and 1.4571 / 316 Ti Density range 0 to 5000 kg/m³ (0 Ib/ft³ to 11023.11 Ib/ft³) Calibration range 400 to 2000 kg/m³ (881.85 Ib/ft³ to 4409.25 Ib/ft³) Accuracy up to ±0.01% (±0.1kg/m³ – ±0,22 Ib/ft³) Repeatability up to ±0.005% (±0.05kg/m³ – ±0.11 Ib/ft³) Process temperature -40°C to +150°C (-40°F to + 302) Process pressure 100 bar (1450 psi) Output With transmitter electronics: 2-wire current output 4-20mA for operating density, reference density, concentration, °Brix, °Plato or other quantities derived from density With preamplifier: Vibration frequency modulated to output current and output of the medium temperature by PT100 in 4-wire technology or by 4-20 mA transmitter for evaluation by an external flow or density computer (e.g. series UR 06). Ex-protection Flame proof or intrinsically safe SPECIAL FEATURES· high measurement accuracy· 2-wire technology· special alloy of NiFeCr and 1.4571· Measurement independent of flow rate· Version without seals· material certificates CHARACTERISTICS· direct measurement of density, reference density or concentration· quality monitoring of liquid media in all industrial sectors.· indirect mass measurement Connection with corresponding volume counters and corrector calculators.· usable in custody transfer applications· very robust construction· low installation costs · Measurement of almost all pumpable non-aggressive liquids or liquid mixtures, especially hydrocarbons