im-tek.com

Dynisco ECHO-MV3-BAR-R22-UNF-6PN-S06-F30-NTR Melt Pressure Transducers

Dynisco

Product Code: ECHO-MV3-BAR-R22-UNF-6PN-S06-F30-NTR Melt Pressure Transducers
Artikelnummer: Art.Nr. : E12711131
Brand: Dynisco



GET OFFER: info@imtek.com.tr

Description for Dynisco ECHO-MV3-BAR-R22-UNF-6PN-S06-F30-NTR Melt Pressure Transducers

·         2 year warranty and 60 years of Dynisco industry experience·         Accuracy better than ±0.5%·         TiAlN diaphragm coating is standard·         mV/V, 0-10VDC, or mA outputs available·         Integral temperature sensor option·         Available in configurations that fit most extruder applications·         1.5M, 3M, 5M, 7.5M & 10M psi pressure range capability·         Alternative fill model available  Operating Principle The Dynisco EchoTM Melt Pressure Sensors are used to make pressure measurements of molten polymers up to 752°F (400°C). These models incorporate a 350?Ohm, bonded foil strain gage Wheatstone Bridge. This proven technology provides an output of 0?3.33 mV/V, & 4?20mA, 05?VDC and 0?10VDC proportional to melt pressure (within the specified error band). Most models include an internal shunt calibration ("Rcal") function that is used to simulate a signal of 80% of full scale. This eliminates the need for a cumbersome calibrated pressure source when scaling associated instrumentation. Installation Do not remove protective cap until ready to install. Prior to initial installation, verify correct machining of mounting hole per Figure 1. Gauge Plug, P/N 200908, is available for this purpose. Before installing make sure that mounting hole is clear of material. Dynisco Cleaning Tool Kit, P/N 200100, should be used. To prevent galling, lightly coat transducer threads with a high temperature anti?seize material. An adequate seal, in a properly machined and maintained mounting well, is obtained with 100 in?lbs. mounting torque. The maximum torque recommended is 500 in?lbs. The electronics housing should be secured, with the optional mounting bracket (P/N 200941), in an area where the ambient temperature will not exceed 185°F (85°C). (Mounting bracket not supplied with EchoTM models.)Wiring Use shielded cable. Attach cable shield to ground at one end only. NOTE: DYNISCO cable assemblies are constructed with shield wired to transducer mating connector, so do not attach shield to instrument. Output Supply Voltage mV/V 10 Vdc (12 Vdc max) mA 14?36 Vdc Vdc 16?36 Vdc Start?Up Bring system to operating temperature with no pressure. For mA units, remove adjustment access screw and adjust Zero Output potentiometer. For mV/V units, zero adjustment must be handled by downstream indicator. Make sure that there is sufficient "soak time" to assure that any material at the tip of the transducer is molten before extruder drive is started. Removal Transducer should only be removed when polymer is hot and liquid. Wipe tip with a soft cloth immediately. The melt pressure transducer must be removed before using an abrasive material or wire brush to clean the extruder barrel. Clean the mounting well before attempting to reinstall the transducer with Dynisco Mounting Well Cleaning Tool Kit, P/N 200100. Thermocouple Thermocouples ( Type J or K) in a rigid stem are optionally available. The Type J (iron?constantan) and Type K is a T/C junction just behind the flush diaphragm at the tip of the transducer. For the most accurate temperature measurement of the melt stream, use a separate immersion?type thermocouple, such as Dynisco TB422 fixed depth series or (G)RMT adjustable models. The thermocouple assembly can be removed by loosening the set screw on the side of hex assembly and pulling the T/C probe, carefully, straight out, without twisting. Replacement assemblies are available. When installing the thermocouple probe assembly, align the slot with the pressure capillary tube and press into snout until top of probe shoulders flush against snout. Lock in place with set screw.Warranty This Dynisco product is warranted under terms and conditions set forth in the Dynisco Web Pages. Go to www.dynisco.com and click on “Warranty” at the bottom of any page for complete details.

Recommended Products For Dynisco


Dynisco ECHO-MV3-BAR-R22-UNF-6PN-S06-F30-NTR Melt Pressure Transducers
Dynisco IDA354-5c-10V-S78 Pressure Transmitters
Dynisco PT462E-M18-7CB-6/189 Pressure Sensors
Dynisco PT462E-1/2-3M-6/18 Pressure Sensors
Dynisco DYMT-S-1/2-RTD-15-15-G Melt Temperature Probe
Dynisco PT4624-15M-6/18-SIL2 Pressure Sensors
Dynisco PT291- S4-7K-4,8 /3.2R-B906. 6K Pressure Sensors
Dynisco PT482-1/2-10M-6/18-B379 Pressure Sensors
Dynisco DYMT-S-1/2-J-5-15-G Melt Temperature Probe
Dynisco 224200000141 Pressure sensors
Dynisco MDT462F-1-2-3,5C-15-46 Melt Pressure Transmitters
Dynisco EPR3-1.5M-6-TC-M561 Melt Pressure Sensors
Dynisco DYMT-S-1/2-J-25-23-G Melt Temperature Probe
Dynisco SPX2291-S-A-48-K-13-BS-MM-C-AC-ZZ-B300 Pressure Sensors
Dynisco PT462E-3M-6/30 Pressure Sensors
Dynisco MDT462F-1/2-3.5C-15/46-SIL2 Melt Pressure Transmitters
Dynisco 2291NA48K13BUMMACAZZ Pressure Sensors
Dynisco MDT462F-1/2-5C-15/46-T80-SIL2 Melt Pressure Transmitters
Ru-Steel RHP 700 Lamellers H
Italvibras MVLS 06/4200-S90 602952 Low Speed Electric Vibrator
Stenflex Type E DN 32 Expansion Joint
CKD SAB1A-25A-0 Pneumatic Valve
Stauff GMV-3-5S-M-W3/2 NUTS
Eurotherm 3216I/AL/VH/RRXX/R/4XL/G/ENG/ENG/XX/XXXXX/XXXXX/XXXXX/XXXXXX//////////// Indicator Eurotherm 3216I/AL/VH/RRXX/R/4XL/G/ENG/ENG/XX/XXXXX/XXXXX/XXXXX/XXXXXX//////////// Indicator
Alfa Laval 9612644020 BALL VALVE SBV-ISO38-W/W-NCTT EPDM
Taprogge PL150 Cleaning Ball
Indexator 8000307 IR 10 M16 Rotator
Hengstler AC58/1212EF.46DPZ Absolute Encoder
Faggiolati X471M6V2-L50LB7 Pump
Bucher Qt43-025R Hydraulik Pump
Alfa Laval LKLA Ø133 101.6/DN100 A/A 9612271308 Actuator
Nippon TOP-11MA Trochoid® Pumps
Scherzinger 4030-710-B-DM-55-2-Exe Stainless Steel Gear Pumps 4030
Spirax Sarco BSA1T PN16 DN200 Metal Bellows Valve
Atlas Copco 1624 0750 00 Strainer
Vulcanic 2285-03 Flange Immersion Heater
Asco Numatics 6JSPA4U-5 Valve
Atos CK-9-50/36-0480-L308-B1E3X1Z3 XY-420 Cylinder
Micro Detectors NX14SR/XCP-C000 Area Sensor
SKF PHG A70 Dim:13x1775 Belt
Habasit T04/U Amber Harlequin TPU Belt
Mp Filtri FZP1363BAA6A10ZP01 Filter