im-tek.com

Dynisco ECHO-MV3-BAR-R22-UNF-6PN-S06-F30-NTR Melt Pressure Transducers

Dynisco

Product Code: ECHO-MV3-BAR-R22-UNF-6PN-S06-F30-NTR Melt Pressure Transducers
Artikelnummer: Art.Nr. : E12711131
Brand: Dynisco



GET OFFER: info@imtek.com.tr

Description for Dynisco ECHO-MV3-BAR-R22-UNF-6PN-S06-F30-NTR Melt Pressure Transducers

·         2 year warranty and 60 years of Dynisco industry experience·         Accuracy better than ±0.5%·         TiAlN diaphragm coating is standard·         mV/V, 0-10VDC, or mA outputs available·         Integral temperature sensor option·         Available in configurations that fit most extruder applications·         1.5M, 3M, 5M, 7.5M & 10M psi pressure range capability·         Alternative fill model available  Operating Principle The Dynisco EchoTM Melt Pressure Sensors are used to make pressure measurements of molten polymers up to 752°F (400°C). These models incorporate a 350?Ohm, bonded foil strain gage Wheatstone Bridge. This proven technology provides an output of 0?3.33 mV/V, & 4?20mA, 05?VDC and 0?10VDC proportional to melt pressure (within the specified error band). Most models include an internal shunt calibration ("Rcal") function that is used to simulate a signal of 80% of full scale. This eliminates the need for a cumbersome calibrated pressure source when scaling associated instrumentation. Installation Do not remove protective cap until ready to install. Prior to initial installation, verify correct machining of mounting hole per Figure 1. Gauge Plug, P/N 200908, is available for this purpose. Before installing make sure that mounting hole is clear of material. Dynisco Cleaning Tool Kit, P/N 200100, should be used. To prevent galling, lightly coat transducer threads with a high temperature anti?seize material. An adequate seal, in a properly machined and maintained mounting well, is obtained with 100 in?lbs. mounting torque. The maximum torque recommended is 500 in?lbs. The electronics housing should be secured, with the optional mounting bracket (P/N 200941), in an area where the ambient temperature will not exceed 185°F (85°C). (Mounting bracket not supplied with EchoTM models.)Wiring Use shielded cable. Attach cable shield to ground at one end only. NOTE: DYNISCO cable assemblies are constructed with shield wired to transducer mating connector, so do not attach shield to instrument. Output Supply Voltage mV/V 10 Vdc (12 Vdc max) mA 14?36 Vdc Vdc 16?36 Vdc Start?Up Bring system to operating temperature with no pressure. For mA units, remove adjustment access screw and adjust Zero Output potentiometer. For mV/V units, zero adjustment must be handled by downstream indicator. Make sure that there is sufficient "soak time" to assure that any material at the tip of the transducer is molten before extruder drive is started. Removal Transducer should only be removed when polymer is hot and liquid. Wipe tip with a soft cloth immediately. The melt pressure transducer must be removed before using an abrasive material or wire brush to clean the extruder barrel. Clean the mounting well before attempting to reinstall the transducer with Dynisco Mounting Well Cleaning Tool Kit, P/N 200100. Thermocouple Thermocouples ( Type J or K) in a rigid stem are optionally available. The Type J (iron?constantan) and Type K is a T/C junction just behind the flush diaphragm at the tip of the transducer. For the most accurate temperature measurement of the melt stream, use a separate immersion?type thermocouple, such as Dynisco TB422 fixed depth series or (G)RMT adjustable models. The thermocouple assembly can be removed by loosening the set screw on the side of hex assembly and pulling the T/C probe, carefully, straight out, without twisting. Replacement assemblies are available. When installing the thermocouple probe assembly, align the slot with the pressure capillary tube and press into snout until top of probe shoulders flush against snout. Lock in place with set screw.Warranty This Dynisco product is warranted under terms and conditions set forth in the Dynisco Web Pages. Go to www.dynisco.com and click on “Warranty” at the bottom of any page for complete details.

Recommended Products For Dynisco


Dynisco MDA462-1/2-3,5C-32/46 Pressure Sensors
Dynisco ECHO-MV3-BAR-R21-UNF-6PN-S06-F18-NTR Melt Pressure Transducers
Dynisco ECHO-MV3-PSI-R21-UNF-6PN-S06-F18-NTR Melt Pressure Transducers
Dynisco PT462E-5M-6/18 Pressure Sensors
Dynisco MDT462F-1-2-3,5C-15-46 Melt Pressure Transmitters
Dynisco 1390-2-3 Temperature Indicator
Dynisco PT160-3M-H3 Pressure Sensors
Dynisco ECHO MA4 MPA R23 UNF 6PN S06 F18 NTR Melt Pressure Sensors
Dynisco TPT4634-1/2-3.5CB-6/18-SIL2 Pressure Sensors
Dynisco MDT463H-1/2-5C-15/46 Pressure Sensors
Dynisco MDA460-1/2-5C-15 Pressure Sensors
Dynisco SPX2291-S-A-48-K-13-BS-MM-C-AC-ZZ-B300 Pressure Sensors
Dynisco PT-242FM-20MPA-6 Pressure Sensors
Dynisco ECHO-MV3-BAR-R21-UNF-6PN-S06-F18-NTR Melt Pressure Transducers
Dynisco PT462E-3.5CB-6/18 Pressure Sensors
Dynisco MDT462F-M18-7C-15/46-A Melt Pressure Transmitters
Dynisco SPX2291SA56K09BSTTCCAZZ Pressure Sensors
Dynisco 149041000 Panel Indicator
KSB UPFN 80/13+UMAI150-8/22-S.D Pump
Fortress Interlocks T3A 3 Position Illuminating Selector Switch
Dynisco PT4624-15M-6/18-SIL2 Pressure Sensors
KSB MCPK065-040-200 EC NP2 A Pump
KSB ETN 050-032-250 GG CP1CGA2 B Pump
Wandfluh WDE45/23x50 Solenoid coil
Fluorolined PVDF Series-II Horizontal Pump
Parker DFBO1010FSVAFMD33WPMA Duplex Filter
Eurotherm TE10A 50A/440V/0V10/PA/ENG/230V/CL/NOFUSE/-//00 Inverter Drive Eurotherm TE10A 50A/440V/0V10/PA/ENG/230V/CL/NOFUSE/-//00 Inverter Drive
KSB Amarex KRT ~ D 100-316/16 4 Pump
Vulcanic 6008-21 Standart Industrial Radiator
Meister DKG-2/2 Flow Monitor And Indicator For Oil
CKD SSD2-25D-10 Compact Cylinder
Unimec 16-04946 Gear Box With Motor
Tokimec EPMX2-3/5 Proportional Solenoid Pressure Reducing Valves
Keller PA-21Y / 500 Bar / 22-2155-154 Pressure Transmitter
Abb 1SFA896109R7000 PSR30-600-70 Soft Starter
FIP Italy VXEFC Series DN 10÷50 Easyfit 2-way Ball Valve
Stauff STDA-016-ECO-P4-U-M-N-1 0,16 liter 250 bar Diaphragm Accumulator
Sensitron S4590BU Gas Detector
Stauff SMA-20-G1/2-V-OR-W5 Connector
Goizper 57125804 Half Slats
HEIDENHAIN LS 177 Sealed Linear Encoder
Eaton 02-346171 PVH131* 40 Kit Shaft Bearing