im-tek.com

Dynisco ECHO-MV3-MPA Melt Pressure Transducers

Dynisco

Product Code: ECHO-MV3-MPA Melt Pressure Transducers
Brand: Dynisco



GET OFFER: info@imtek.com.tr

Description for Dynisco ECHO-MV3-MPA Melt Pressure Transducers

·         2 year warranty and 60 years of Dynisco industry experience·         Accuracy better than ±0.5%·         TiAlN diaphragm coating is standard·         mV/V, 0-10VDC, or mA outputs available·         Integral temperature sensor option·         Available in configurations that fit most extruder applications·         1.5M, 3M, 5M, 7.5M & 10M psi pressure range capability·         Alternative fill model available  Operating Principle The Dynisco EchoTM Melt Pressure Sensors are used to make pressure measurements of molten polymers up to 752°F (400°C). These models incorporate a 350?Ohm, bonded foil strain gage Wheatstone Bridge. This proven technology provides an output of 0?3.33 mV/V, & 4?20mA, 05?VDC and 0?10VDC proportional to melt pressure (within the specified error band). Most models include an internal shunt calibration ("Rcal") function that is used to simulate a signal of 80% of full scale. This eliminates the need for a cumbersome calibrated pressure source when scaling associated instrumentation. Installation Do not remove protective cap until ready to install. Prior to initial installation, verify correct machining of mounting hole per Figure 1. Gauge Plug, P/N 200908, is available for this purpose. Before installing make sure that mounting hole is clear of material. Dynisco Cleaning Tool Kit, P/N 200100, should be used. To prevent galling, lightly coat transducer threads with a high temperature anti?seize material. An adequate seal, in a properly machined and maintained mounting well, is obtained with 100 in?lbs. mounting torque. The maximum torque recommended is 500 in?lbs. The electronics housing should be secured, with the optional mounting bracket (P/N 200941), in an area where the ambient temperature will not exceed 185°F (85°C). (Mounting bracket not supplied with EchoTM models.)Wiring Use shielded cable. Attach cable shield to ground at one end only. NOTE: DYNISCO cable assemblies are constructed with shield wired to transducer mating connector, so do not attach shield to instrument. Output Supply Voltage mV/V 10 Vdc (12 Vdc max) mA 14?36 Vdc Vdc 16?36 Vdc Start?Up Bring system to operating temperature with no pressure. For mA units, remove adjustment access screw and adjust Zero Output potentiometer. For mV/V units, zero adjustment must be handled by downstream indicator. Make sure that there is sufficient "soak time" to assure that any material at the tip of the transducer is molten before extruder drive is started. Removal Transducer should only be removed when polymer is hot and liquid. Wipe tip with a soft cloth immediately. The melt pressure transducer must be removed before using an abrasive material or wire brush to clean the extruder barrel. Clean the mounting well before attempting to reinstall the transducer with Dynisco Mounting Well Cleaning Tool Kit, P/N 200100. Thermocouple Thermocouples ( Type J or K) in a rigid stem are optionally available. The Type J (iron?constantan) and Type K is a T/C junction just behind the flush diaphragm at the tip of the transducer. For the most accurate temperature measurement of the melt stream, use a separate immersion?type thermocouple, such as Dynisco TB422 fixed depth series or (G)RMT adjustable models. The thermocouple assembly can be removed by loosening the set screw on the side of hex assembly and pulling the T/C probe, carefully, straight out, without twisting. Replacement assemblies are available. When installing the thermocouple probe assembly, align the slot with the pressure capillary tube and press into snout until top of probe shoulders flush against snout. Lock in place with set screw.Warranty This Dynisco product is warranted under terms and conditions set forth in the Dynisco Web Pages. Go to www.dynisco.com and click on “Warranty” at the bottom of any page for complete details.  

Recommended Products For Dynisco


Dynisco 462200000292 Pressure Sensor
Dynisco 2291NA48K13BUMMACAZZ Pressure Sensors
Dynisco PT462E-1/2-15M-12/18 Pressure Sensors
Dynisco MDA460-1/2-1M-15 Pressure Sensors
Dynisco PT462E-5M-6/18 Pressure Sensors
Dynisco TPT4634-3.5CB-6/18-SIL2 Pressure Sensors
Dynisco PT460E-5CB-6 Pressure Sensors
Dynisco DYMT-S-M18-J-5-15-G-2M-A Melt Temperature Probe
Dynisco PT160-5C Pressure Sensors
Dynisco MDT462F-1/2-1C-15/46-SIL2 Melt Pressure Transmitters
Dynisco MDT422F-1/2-3,5C-23/46-A Melt Pressure Transmitters
Dynisco PT160-5M Pressure Sensors
Dynisco MDT462F-1/2-5C-15/46-SIL2 Melt Pressure Transmitters
Dynisco MDT462F-1/2-5C-15/46-T80-SIL2 Melt Pressure Transmitters
Dynisco UPR900-20000001 Process Indicator
Dynisco ECHO-MV3-PSI-R21-UNF-6PN-S06-F18-NTR Melt Pressure Transducers
Dynisco PT462E-15M-12/18 Pressure Sensors
Dynisco ATC990400110000 Process Controller
Westcode N1581QL160 Phase Control Thyristors-Capsule
Kadant 997.228 ELS Rotary Joint
Topworx TVL-M20GNPM - 1/2Inch NPT, NAMUR 304 SS Shaft, Aluminium Base & Lid, TVL Series Valve Controller
Asco SCE238-D005 Solenoid Valve
MAC 414A-D0A-DM-DDAJ-1JD Pneumatic Valve
Bollfilter 3030466 O-ring For Dual Fuel Filter
Bürkert 8792 24VDC 00206611 Pozisyoner Side Control
Hengstler RI58-O/10000AK.72TH Encoder
SKF Type:FPM Dim:710X10mm O-ring Seal
Kadant 9940013/0002 SX Rotary Joint
Parker DF25120QEVM3GG121 Duplex Filter
Joyce/Dayton AN150R038B Acme Screw and Nuts
Revere SHBXR-100KG-C3-SC-ATEX Single-Ended Load Beam
Atos HR-012 50 Check Valve
Pizzato NF B112KC-DN2 Switch
SKF 24130 CC/C3W33 Bearing
Eaton DU251-0299 Duplex Filter
Autel MDKIT50 2 Diaphragm
Grundfos 98546247 Pump Service Kit
Senseca HD32.3TC Datalogger
CMO Serie R Check Valve
Gefran PA-1-C-075 Transducer
Pactrol P16DI 400601 Gas Control
Seim PXF Series 3 Screw Pumps